R-2015-036 2015-02-23RESOLUTION NO. R2015-36
A Resolution of the City Council of the City of Pearland, Texas,
authorizing the City Manager or his designee to enter into Agreements
with CenterPoint Energy Houston Electric, LLC, ("CenterPoint") for (1)
the removal and relocation of power lines near Fruge Road and (2) the
installation of underground primary conductors along Kirby Drive from
Fruge Road north approximately 1500 feet.
BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF PEARLAND, TEXAS:
Section 1. That certain Agreements by and between the City of Pearland and
CenterPoint, a copies of which is attached hereto and made a part hereof for all purposes,
are hereby authorized and approved.
Section 2. That the City Manager or his designee is hereby authorized to execute
and the City Secretary to attest Agreements with CenterPoint.
PASSED, APPROVED and ADOPTED this the 23rdday of February,
A.D., 2015.
ATTEST:
APPROVED AS TO FORM:
(L„
DARRIN M. COKER
CITY ATTORNEY
•
TOM REID
MAYOR
0.
=U�
Resolution No. R2015-36
Exhibit "A"
Chapter 6: Company Specific Items
CenterPoint Energy Houston Electric, LLC
Applicable: Entire Service Area
6.3 AGREEMENTS AND FORMS
6.3.1 FACILITIES EXTENSION AGREEMENT
Sheet No. 6.24
Page 1 of 2
CNP 8038
This Facilities Extension Agreement is entered into by and between
CITY OF PEARLAND , herein
called "Retail Customer" and CenterPoint Energy Houston Electric, LLC, herein called
"Company" (hereinafter referred to as Agreement) for the construction, extension, installation,
modification, repair, upgrade, conversion, relocation, de-energization or removal of Company's
Delivery System, including temporaiy facilities (hereinafter referred to as facilities extension or
extension), as described herein.
This Agreement covers the facilities extension to Retail Customer location at
15015 KIRBY DR., PEARLAND, TEXAS 77584
The Company agrees to accept payment of S 49, 164.00 Dollars
to be paid by the Retail Customer, as a Non -Refundable Construction Payment in connection
with the Retail Customer request to extend Company facilities to the above described location as
follows:
INSTALLATION OF OVERHEAD DISTRIBUTION INCLUDING (4) TERMINAL POLES
(3) 250 KVA STEP DOWN TRANSFORMERS AND REMOVAL OF EXISTING OVERHEAD DISTRIBUTION
CROSSING KIRBY DR.: RIGHT OF WAY.
• Unless otherwise stated by Company in writing, the Non -Refundable Construction
Payment amount above is valid for twelve months.
In consideration of said Non -Refundable Payment, to be paid to Company by Retail Customer
prior to commencement of construction, Company agrees to install and operate lines and
equipment necessary to distribute electric service to the identified location under the following
General Conditions:
• Company shall at all times have title to and complete ownership and control over
facilities installed by Company.
• Retail Customer must make satisfactory payment arrangements (if payment is required to
extend Company facilities) and sign and return this Agreement before Company can
proceed with the requested extension.
Revision Number: 5th 306 Effective: 9/1/11
Chapter 6: Company Specific Items
CenterPoint Energy Houston Electric, LLC
Applicable: Entire Service Area
Sheet No. 6.24
Page 2 of 2
CNP 8038
• Extension of service facilities is contingent on acquisition of all necessary easements and
rights of way.
Nothing herein contained within this Agreement shall be construed as a waiver or relinquishment
by Company of any right that it has or may hereafter have to discontinue service for or on
account of default in the payment of any bill owing or to become owing thereafter for any other
reason or cause stated in Company's Tariff.
This Agreement shall not be binding upon Company unless and until it is signed by an
authorized representative of the Company.
CenterPoint Energy Houston Electric, LLC
Retail Customer
By i w N " By
Jon Branson
JO A.SALINAS
(name printed or typed) (name printed or typed)
Title SR. SERVICE CONSULTANT Title
Date 06/11/2014
Deputy City Manager
Date 02/23/2015
Revision Number: 5th307 Effective: 9/1/11
9 JJ9IHX3
CenterPoint.
Energy
June 6, 2014
RE: Terms and Conditions Package
CITY OF PEARLAND
Overhead to Underground Relocation
Kirby from Fruge north 1500'
Pearland, TX
Job 1168829612
Dear Customer:
CenterPoint Energy
3000 Harrisburg Blvd. #A
Houston, Texas 77003
Please reference the enclosed Terms & Conditions (T&C) package Job 1168829612 in response to a
request by Trent Epperson of the City of Pearland in a meeting on May 12, 2013 to provide cost for the
relocation of existing overhead feeder mains to underground along Kirby from Fruge north
approximately 1500 feet.
The cost of Centerpoint Energy's construction is as follows:
Underground Primary
(conduits and manholes by City of Pearland) $ 276,000.00
Total
The cost listed above do not include overhead removal and any other overhead construction. Those
cost will be provided in a separate FEA by John Salinas from H. 0. Clarke Service Center. The
customer will be responsible for the construction of the duct lines and manholes. The customer will
construct those items according to the specifications within the T&C package which is attached.
The referenced T&C package and cost are effective for 365 days from June 6, 2014 provided the field
conditions existing as of this date and location of the facilities shown on the sketches within the T&C
package remain the same. After that time, the T&C package and estimates must be reviewed by the
Major Underground Engineering department (MUG) and the Overhead Service Center before a final
commitment can be made. The information contained within the T&C package is applicable for the
life of the service.
If the T&C package is in accordance with your understanding, we would appreciate a representative for
City of Pearland Indicating acceptance by signing the cover sheet of the T&C package and the
applicable Facilities Extension Agreements (FEA).
Please return the signed original of the FEA and the cover sheet of the T&C package to me at 3000A
Harrisburg Boulevard, Houston Texas 77003 along with the remittance in the amount listed on the
FEA. That will be our authority to proceed with this project.
Page 1 1
CenterPoint.
Iv Energy
If you have any questions, please contact me at the number below.
Sincerely,
Norbert D. Gonzales
Lead Engineering Specialist
713-207-6168
norbert.gonzales@centerpointenergv.com
Page 1 2
CenterPoint Energy
3000 Harrisburg Blvd. #A
Houston, Texas 77003
REFERENCE
Site
Utility
REFERENCE
Service
Ready
Reviewed
TERMS & CONDITIONS
UNDERGROUND ELECTRIC SERVICE,
FOR
CITY OF PEARLAND
OVERHEAD RELOCATION TO UNDERGROUND
Kirby from Fruge to 1500' north
Job #68829612
CenterPoint Energy (CNP)
Major Underground Engineering
P. O. Box 1700; Houston, Texas 77251-1700
DRAWINGS:
Plan Received: None
Plan & Profile Drawing: None
CENTERPOINT ENERGY SPECIFICATIONS:
Standards•
. April 1 , 2014
-Mix Concrete•
. 007-221-01
And Agreed To B Deputy City Manager 02/23/2015
Signature Title
Jon Branson
an official
will be
package.
Date
from CITY
Print
If this Terms & Conditions package
OF PEARLAND it will not be
Name
is signed by
considered valid.
within
anyone other than
A valid signature
this Tenns & Conditions
considered an
acceptance of all information contained
CenterPoint Energy
Houston, Texas
WRITTEN
NDG
06/06/2014
CHECKED
NOG
06/06/2014
APPROVED
RED
06/06/2014
SHEET 1 OF 14 SHEETS
NO.
DATE
ITEMS REVISED
[Y
CH
APP
F00573
Job 1168829612
GENERAL
A. These Terms and Conditions are for the installation of underground facilities in place of
proposed overhead facilities for CITY OF PEARLAND. CITY OF PEARI,AND and/or
its contractors/representatives are herein referred to as the Customer.
B. The CNP Major Underground Engineering (MUG) representative is Norbert Gonzales at
713-207-6168 or Norbert.Gonzales@CenterPointEnergy.com.
The CNP Service Area Consultant is John Salinas at 713-945-4484 or
John.Salinas@centerpointenergy.com.
C. The Customer must comply with all CNP Service Standards, the National Electrical Code,
the National Electrical Safety Code, all Occupational Safety and Health Administration
(OSHA) requirements, the International Building Code and all local governing body
codes.
D. During installation of CNP equipment, CNP will make every effort to preserve the
Customer's landscaping, parking areas, or other facilities. However, any cost that has been
quoted to the Customer does not include any special replacements or repairs to these
items. The Customer shall be solely responsible for any expenses associated with
replacements or repairs to its facilities.
E. The service arrangement outlined in these Terms and Conditions is based on the Customer
request and customer drawings referenced on page 1. Any changes in the design as
illustrated in the referenced drawings may impact CNP's ability to meet the Customer's
requested service date.
Any changes, additions, deletions, rearrangements, relocations, rerouting, reduction of
clearances, etc., of the Customer's and/or CNP's service facilities illustrated in these Terms
and Conditions shall have the MUG's approval and may require a revised Terms and
Conditions. It is the Customer's responsibility to coordinate the location of all Customer
installed facilities outlined in these Terms and Conditions with all other structures and/or
appurtenances not shown in the referenced drawings.
F. Contact the MUG representative concerning Customer drawing revisions, information
submission, questions, Terms and Conditions revision requests, etc.
G. Hard copy submittals may be mailed to the MUG representative (address — 3000A
Harrisburg Blvd. — Houston, Texas 77003). Electronic submittals may be e-mailed to the
MUD Engineering representative. The MUG representative will; "approve the submittals",
"approve the submittals as noted" or "not approve the submittals". The Customer shall not
install any item that requires CNP approval before receiving an official approval from the
MUG. CNP shall not be responsible for any installed item that has not received MUG
approval.
H. CNP requires a minimum of 90 calendar days for the installation of the underground
cables and framing of the associated terminal poles. Then the overhead removal can begin.
CNP owned poles will be removed after aerial telecom facilities have been removed. No
CNP poles will be allowed to remain for the use of telecom or other facilities if CNP
distribution facilities are removed from those poles.
REVISION NO.
SPECIFICATION NO.
SHEET 2 OF 14 SHEETS
Job 1168829612
ACCESS
The Customer must provide a twelve foot (12') minimum width, fourteen foot (14') minimum
vertical clearance, all weather, vehicle access road designed for HS -20-44 loading as recognized
by the American Association of State Highway Officials (AASHO), for CNP personnel and
equipment to the proposed terminal poles and manholes. If the access road has not been
completed and passed final inspection (sec Final Inspection, page 5) at the time the Customer
requests the cable to be installed, the cable can only be set under the following conditions.
A. The MUG has determined that the access route is dry and readily accessible to CNP's
normal installation equipment.
B. The Customer shall be responsible for all expenses associated with the repair and/or
replacement of CNP underground facilities damaged by additional construction
activity. Damage to CNP equipment may result in delays to the Customer's requested
service date.
C. CNP will not complete the underground construction (i.e. pulling & terminating
cable, energizing the service, etc.) until the access road and duct bank location has
passed final inspection (see Final Inspection, page 5).
The Customer must maintain these requirements for the life of the service.
CNP will utilize the existing streets Fruge, Kirby and the existing paved parking areas for the
required access.
PLAN AND PROFILE DRAWINGS
The Customer must provide plan and profile drawings for the installation of all underground
facilities around the construction area. The Customer is also required to obtain all applicable
construction permits from the appropriate governing authorities. The plan and profile drawings
must be in accordance with CNP standards attached. These drawings must be approved by CNP
and the appropriate governing authorities before beginning the installation of underground
facilities (duct bank, manholes, etc.).
It is recommended that the Customer meet with the MUG representative to discuss the preparation of
the drawings.
The Customer shall supply CNP with mylar originals and electronic files of the approved final
drawings
CNP will keep the original approved drawings on file and furnish one (1) copy to the Customer. If
the Customer requests additional copies, CNP will arrange to supply copies or reproducible mylars at
the Customer's expense.
If the actual installation differs from the proposed routing on the drawings, then the Customer shall
provide CNP with one (1) set of bluelines, rnarked in red pencil, to indicate AS BUILT corrections.
REVISION NO. SPECIFICATION NO. SHEET 3 OF 14 SHEETS
Job 1168829612
TRAFFIC CONTROL PLAN
The Customer must provide a traffic control plan that has been approved by the appropriate
governing authorities before beginning the installation of underground facilities (duct bank,
manholes, etc.).
FACILITIES INSTALLED BY THE CUSTOMER
All facilities are to be installed per the attached construction specifications. The Customer or its
contractor is to request a preconstruction meeting prior to starting the required underground
construction by calling the number listed below.
All facilities shall be inspected by CNP after the conduit is installed; pads are formed, reinforcing
rods installed, etc. but prior to the pouring of concrete. CNP recommends that the Customer
complete the pouring of concrete on the day the facilities are inspected and approved. The
Customer will insure that all inspected and approved facilities remain in the approved condition
until the concrete pour has been completed. If there is damage to the inspected and approved
facilities prior to the pouring of concrete, the facilities must be re -inspected by CNP before the
Customer begins the pouring of concrete. CNP reserves the right to require the Customer to break
out any unapproved concrete pours at its expense.
CNP will make a reasonable attempt to complete all inspection requests. To insure that inspection
requests can be fulfilled, they should be made twenty-four (24) hours in advance (Mon. - Fri.;
between 9:00 a.m. and 3:00 p.m., holidays excluded) to the MUG at (713) 207-6229. Job
#68829612 must be provided as the inspection identification number.
DUCT BANK INSTALLATION
All proposed conduit for CNP's use is to be installed in straight runs, unless otherwise indicated on
CNP drawings. Any conduit bends other than ninety degrees must be installed with a three-foot
(3') minimum radius, unless indicated otherwise on CNP drawings. All ninety degree bends,
conduit turn -ups into any equipment pad and/or pole pedestal must have a minimum five-foot (5')
radius. Any deviations from these requirements shall have written approval from the MUG
representative prior to installation.
During installation, the minimum depth for a conduit run must be referenced to the final grade.
The Customer is to delay installation of approximately the last twenty feet (20') of the conduit run
and the pole pedestal to any terminal pole until the pole has been set by CNP. Before trenching to
the base of any terminal pole, the Customer must securely brace the pole. The Customer must
request staking and setting of any terminal pole by contacting the Service Area Consultant.
The Customer must provide a jet line in each conduit installed. This jet line shall extend a
minimum of seven feet (7') beyond the end of each conduit.
REVISION NO.
SPECIFICATION NO. I -I- J
SHEET 4 OF 14 SHEETS
Job #68829612
DUCT BANK INSTALLATION (CONTINUED)
Conduit ends shall be plugged with a conduit cap or plug. The use of rags and or tape to plug
conduits is not acceptable. If the conduit is installed in stages, the Customer must keep each
section of conduit sealed until the new section is installed. If, prior to CNP using any conduit, the
conduit is found to be blocked, the Customer will be responsible, at its expense, for removing the
obstruction.
CLEARANCES
Final approval for the location of the terminal poles and manholes is contingent upon proper
clearance, as determined by CNP, from cooling towers, vents, buildings, structures, etc., and other
underground utilities. It is in the Customer's and CNP's best interest to have all service equipment
in a contamination -free environment to avoid unscheduled outages and/or premature equipment
failures. Therefore, prior to any construction, the Customer shall inform the MUG representative
of any existing or future contamination or pollutants which may affect the equipment so that
necessary clearances can be secured.
The MUG representative shall be notified promptly if the Customer intends to install any
obstructions such as walls, hedges, bushes, trees, etc., around the transformer and/or any
associated equipment so that additional clearances and access can be secured. Any proposed
enclosure surrounding CNP's equipment must be louvered, and both a profile and a cross-sectional
view of the proposed louvered enclosure shall be submitted for approval prior to installation.
If, in the future, there is a problem with contamination of CNP's equipment, or proper clearances
are not maintained, CNP reserves the right to relocate the equipment at the Customer's expense.
A one foot (1') minimum vertical clearance must be maintained between CNP duct banks and all
non -CNP facilities crossing the duct bank.
A five foot (5') minimum horizontal clearance must be maintained between CNP duct banks and
other facilities running parallel to the duct bank. CNP will not allow joint trenching between CNP
duct banks and other facilities.
No telecommunication, electrical, or any other entities facilities' are to use CNP terminal poles as
a point to riser from underground to overhead. Existing aerial attachments to the terminal poles
may be accommodated if approved by the MUG representative. In order to maintain proper
clearances the installation of taller terminal poles or relocation of the foreign attachments may be
required
FINAL INSPECTION
After the Customer has advised CNP that all "Customer installed" facilities pertaining to this
service arrangement have been completed and inspected, a final on-site inspection will be made by
a MUG representative. This final inspection will verify that all Customer installed facilities are in
accordance with these Terms and Conditions. The Customer (or its contractor) and the Service
Area Consultant will be advised of any needed corrections and/or changes. When all necessary
corrections and/or changes have been completed, CNP's portion of the construction may begin
REVISION NO.
SPECIFICATION NO.
SHEET 5 OF 14 SHEETS
Job #68829612
INDEMNIFICATION AND LIABILITY LIMITS
Indemnity: This indemnity is pursuant to Company's Tariff located on our website at
www.centerpointenergy.com.
Indemnity: This indemnity is pursuant to Company's Tariff located on our website at
www.centerpointenergy.com.
RETAIL CUSTOMER ASSUMES THE RISK OF AND SIIALL INDEMNIFY COMPANY
AGAINST DAMAGES FOR INJURIES OR DEATH TO PERSONS OR LOSS TO RETAIL
CUSTOMER'S PROPERTY, OR TO THE PROPERTY OF COMPANY, WHEN OCCASIONED
BY ACTIVITIES OF RETAIL CUSTOMER OR THIRD PARTIES ON CUSTOMER'S
PREMISES, RESULTING FROM THE INSTALLATION, EXISTENCE, REPLACEMRNT, OR
REPAIR OF COMPANY'S UNDERGROUND FACILITIES, AND AS FURTHER PROVIDED
IN THE TERMS OF "LIMITS ON LIABILITY," SECTIONS 4.2 AND 5.2 OF THIS
TARIFF. NOTWITHSTANDING ANY OF THE ABOVE, THE PROVISIONS REQUIRING A
RETAIL CUSTOMER TO INDEMNIFY, FULLY PROTECT, OR SAVE COMPANY
HARMLESS APPLY TO A GOVERNMENTAL ENTITY AS THIS TERM IS DEFINED IN
CHAPTER 2251 OF THE TEXAS GOVERNMENT CODE, TO THE EXTENT OTHERWISE
CONSISTENT WITH LAW; PROVIDED, HOWEVER, THAT ANY GOVERNMENTAL
ENTITY THAT IS A RETAIL CUSTOMER TO WHICH THIS SUBSECTION 2.5 APPLIES
MUST TAKE NECESSARY STEPS TO ENSURE THAT THE INDEMNIFICATION
REQUIREMENTS OF THIS SUBSECTION 2.5 DO NOT CREATE A "DEBT" IN VIOLATION
OF ARTICLE XI, SECTION 7 OF THE TEXAS CONSTITUTION. SUCH STEPS MAY
INCLUDE, BUT ARE NOT NECESSARILY LIMITED TO, A THIRD -PARTY
INDEMNIFICATION IN WHICH THE CONTRACTOR PERFORMING THE WORK FOR
THE GOVERNMENTAL ENTITY INDEMNIFIES THE COMPANY OR THE
ESTABLISHMENT OF A SINKING FUND. (see Governmental Entity Addendum if applicable.)
REVISION NO. SPECIFICATION NO. SHEET 6 OF 14 SHEETS
4'-0' MINIMUM
FINAL GRADE (ROAD, PARKING AREA, ETC.)
SHEET u 7 OF 14
JOB 0 68829612
•
•
•
E
z
m
:4-
_L.
__ 1 I
a
_ t.. T I• .wa�
_ v ..� . ti -14 '1.' •-121:--14
L -i .-r ''4 • 2' 2 4. 2 2 - 6'
4 - 6, CONDUITS
6 - 6' CONDUITS
CONDUITS
DRIVE #3 REBAR FOR
SPACER ANCHOR
(SEE NOTE 7)
SPACER (SEE NOTE 2)
#3 BARS 3'-0" LONG
(SEE NOTE 5)
(BOTTOM OF
TRENCH)
NOTE: 2 BRICKS
THE CUSTOMER AND/OR ITS CONTRACTOR
IS TO REOUEST A PRECONSTRUCTION MEETING
PRIOR TO STARTING CONSTRUCTION BY CALLING
(713) 207-6229.
NOTES:
1. CONDUIT TO BE PVC, MINIMUM GRADE TYPE E8.
2. SPACERS SHOULD BE INSTALLED NOT MORE THAN 10'-0' APART.
3. CONDUITS TERMINATING AT MANHOLES SHOULD BE SLOPED 0.5%
DOWN TOWARD MANHOLE.
4. ALL EXTERIOR CONCRETE COVER DIMENSIONS ARE MINIMUM.
5. CONCRETE SHALL BE IN ACCORDANCE WITH CNP
SPECIFICATION 007-221-01,LATEST REVISION.
6. PLACE REINFORCING BARS IN 4 CORNERS OF THE CONCRETE
WHERE SPACERS ARE USED.
7. ON COLD JOINT CONCRETE POUR USE *5 REBAR (3'-0' IN LENGTH.
EXPOSED 1'-6').
8. LENGTH OF REBAR FOR SPACER ANCHOR WILL VARY PER DUCT
BANK HEIGHT.
9. CONDUITS ENDS SHALL BE PLUGGED WITH A DUCT CAP OR OTHER
TYPE OF CAPPING DEVICE.
10. A ONE FOOT VERTICAL CLEARANCE MUST BE MAINTAINED BETWEEN
CNP'S DUCTBANK ANO ALL NON -CNP
FACILITIES CROSSING THE DUCTBANK.
11. A FIVE FOOT HORIZONTAL CLEARANCE MUST BE MAINTAINED BETWEEN
CNP'S DUCTBANK ANO ALL NON -CNP
FACILITIES RUNNING PARALLEL TO THE DUCTBANK
(JOINT TRENCHING NOT PERMITTED). THREE PHASE DUCTBANK
12. INSTALL JET LINE IN ALL CONDUITS AND A *14 AWG WIRE FEEDER
IN ONE CONDUIT.
BASED ON DISTRIBUTION STANDARD DLFS2C
PROP
6-6"
DUCT BELL
TERMINATOR
PROP 6-6"
TO MH #02
4.
..
9'-4"
9' -105'8'
BL
8" STABILIZED SAND
PULLING EYE
PLAN VIEW
1'-0" MIN. TO
HIGHEST CONDUIT
1'-0" MIN. TO
LOWEST CONDUIT
to
PVC PIPE SLEEVE
SECTION A -A
NOTES:
1. CNP RECOMMENDS THE INSTALLATION OF
THE REOUIRED DUCTBELL TERMINATORS
BY THE MANHOLE SUPPLIER ON ALL
PRECAST MANHOLES.
2. MANHOLES ARE TO BE PLACED ON A MINIMUM
OF SIX (6) INCH LEVELED BASE OF SAND
OR CRUSHED ROCK TO INSURE UNIFORM
DISTRIBUTION OF SOIL PRESSURE ON THE FLOOR.
3. CNP MUST INSPECT THIS REOUIREMENT PRIOR
TO THE INSTALLATION OF THE MANHOLE
INSIDE THE EXPOSED PIT.
4. THE USE OF PRECAST NECKS IS NOT APPROVED.
SHEET 8 OF 14
JOB #68829612
32" CASTING WITH COVER
BRICK 1" ' GROUT
.,
�1?r M&
' . it • t �
. '.
.
: :
•OHO.
•
SECTION B -B
MANHOLE
#1
LARGE THREE WAY MANHOLE
12KV & 35KV
BASED ON DISTRIBUTION STANDARD MH300
LAS
Br
2'-8'
SLEEVE
PVC PIPE
Os
PULLING
EYE
PROP 6-6"
TO MH 404
t.
PROP 4-6"
TO TP# 3.4
8
7' _81,T
9'-4"
9' -105'e,
BL
8" STABILIZED SAND
PROP 6-6"
TO MH #02
PLAN VIEW
PULLING EYE
,0Q.
Q
1'-0" MIN. TO
HIGHEST CONDUIT
1'-0" MIN. TO
LOWEST CONDUIT
-o
PVC PIPE SLEEVE
SECTION A -A
NOTES:
1. CNP RECOMMENDS THE INSTALLATION OF
THE REOUIRED DUCTBELL TERMINATORS
BY THE MANHOLE SUPPLIER ON ALL
PRECAST MANHOLES.
2. MANHOLES ARE TO BE PLACED ON A MINIMUM
OF SIX (6) INCH LEVELED BASE OF SAND
OR CRUSHED ROCK TO INSURE UNIFORM
DISTRIBUTION OF SOIL PRESSURE ON THE FLOOR.
3. CNP MUST INSPECT THIS REOUIREMENT PRIOR
TO THE INSTALLATION OF THE MANHOLE
INSIDE THE EXPOSED PIT.
4. THE USE OF PRECAST NECKS IS NOT APPROVED.
T
io
MCC
SHEET 9 OF 14
JOB #68829612
32" CASTING WITH COVER
BRICK 1 "e2' GROUT
•
w
0
z
J
J
a
� •1
SECTION B -B
MANHOLE
#3
LARGE THREE WAY MANHOLE
12KV & 35KV
BASED ON DISTRIBUTION STANDARD MH300
13
PROP
6-6"
DUCT BELL
TERMINATOR
DUCT BELL
TERMINATO
9'-4"
B(�
8" STABILIZED SAND
PLAN VIEW
SHEET 10 OF 14
JOB #68829612
32" CASTING WITH COVER
BRICK 1"2' GROUT
4
N
PULLING EYE -
11"
1
1' -O" MIN. TO • ••i
HIGHEST CONDUIT ''•>
1'-0" MIN. TD -P-
LOWEST CONDUIT
PVC PIPE SLEEVE
SECTION A -A
NOTES:
1. CNP RECOMMENDS THE INSTALLATION OF
THE REQUIRED DUCTBELL TERMINATORS
BY THE MANHOLE SUPPLIER ON ALL
PRECAST MANHOLES.
2. MANHOLES ARE TO BE PLACED ON A MINIMUM
OF SIX (6) INCH LEVELED BASE OF SAND
OR CRUSHED ROCK TO INSURE UNIFORM
DISTRIBUTION OF SOIL PRESSURE ON THE FLOOR.
3. CNP MUST INSPECT THIS REQUIREMENT PRIOR
TO THE INSTALLATION OF THE MANHOLE
INSIDE THE EXPOSED PIT.
4. THE USE OF PRECAST NECKS IS NOT APPROVED.
PULLING EYE
V'
•
SECTION B -B
MANHOLE
#2.4.5
LARGE THREE WAY MANHOLE
12KV & 35KV
BASED ON DISTRIBUTION STANDARD MH300
SCRAP PVC
SEE NOTE 5
BY CNP
BY CUSTOMER
GROUND LINE
ry
SEE NOTE 6
NON -THREADED PVC
COUPLING
CONDUIT
5' R
CONCRETE
L.
INLINE PLACEMENT OF CONDUIT
NOTES:
1. CONDUIT BENDS AT TERMINAL POLE SHALL BE PVC.
2. BRACE THE POLE SECURELY BEFORE TRENCHING.
3. INSTALL CONDUIT BENDS TO BASE OF POLE. ADD
PORTIONS OF STRAIGHT CONDUIT AS NECESSARY TO
OBTAIN THE PROPER HEIGHT ABOVE FINAL GRADE.
4. ATTACH COUPLING TO END OF CONDUIT.
5. INSERT, BUT DO NOT GLUE, A SHORT PIECE OF SCRAP PVC
CONDUIT INTO THE TOP COUPLING. TIE CONDUIT TO BRACKET.
6. FORM AREA AROUND PEDESTAL TO THE TOP OF THE COUPLING.
FORM PEDESTAL SO THAT NO CONCRETE WILL CONTACT POLE.
7. AFTER INSPECTION BY CNP, POUR CONCRETE TO
TOP OF COUPLINGS.
8. ALL CONDUITS SHALL HAVE A MINIMUM 4' CONCRETE COVER.
SHEET 11 OF 14
JOB " 6882%12
TERMINAL POLE
#12.3.4
TERMINAL POLE CONDUIT
PLACEMENT 12KV & 35 KV
BASED ON DISTRIBUTION STANDARD 65-500
CenterPoint Energy
MAJOR UNDERGROUND ENGINEERING
WORKING SKETCH
LAMBERT NO. KEY MAP CIRCUIT FUNCTIONAL LOCATION SCALE JOB NO.
5350-C4
612D
SO -46
PROP. CNP SMALL
SAY MANHOLE
NTS
NTS
SHEET : 12 OF 14
68829612
PPVC CCNP �ITS6'
CONC. ENCASED
388'
KIRBY DR
-PROP. CNP SMALL
3 -WAY MANHOLE
•04
KIRBY DR & FRUGE RD
DRAWN BY: EARL JONES 11
LAMBERT NO.
KEY MAP
CenterPoint Energy
MAJOR UNDERGROUND ENGINEERING
WORKING SKETCH
CIRCUIT
FUNCTIONAL LOCATION
SCALE
JOB NO.
SHEET : 13 OF 14
5350-C4
612D
NTS
NTS
NTS
68829612
388' ±
CNP 6-6'
PVC CONDUITS
CONC. ENCASED
PROP. CNP 2-6'
PVC CONDUITS
CONC. ENCASED
TINA
PROP. CNP 2-6'
PVC CONOUI S
CONC. ENCASED
TP63
PROP. p..-6•
PVC CDNDU TS
CONC. ENCASED
(-1
PROP. CNP 6-6'
PVC CONDUITS
CONC. ENCASED
PROP. CNP SMALL
3 -WAY MANHOLE
603
4' +
MATCH LINE B-B
KIRBY DR
KIRBY DR & FRUGE RD
DRAWN BY: EARL JONES 11
LAMBERT NO.
KEY MAP
CenterPoint Energy
MAJOR UNDERGROUND ENGINEERING
WORKING SKETCH
CIRCUIT FUNCTIONAL LOCATION
5350-C4
612D
NTS
NTS
SCALE
NTS
SHEET : 14 OF 14
JOB NO.
68829612
4
l
PROP. CNP 2-6' l
PVC CONDUITS
CONC. ENCASED
TP#I
CO PROP. CNP 2-6'
WPVC CONDUITS
Z CONC. ENCASED
J
7: PROP. CNP SMALL
F
1 -WAY MANHOLE
v01
PROP. CNP 6-6"
PVC CONDUITS
CONC. ENCASED
PROP. CNP SMALL - - -
3 -WAY MANHOLEm02 --�-- ,374_}
KIRBY DR
PROP. CNP 4-6
PVC CONDUITS
CONC. ENCASED
KIRBY DR & FRUGE RD
DRAWN BY: EARL JONES 11