Loading...
Ord. 0233-1 03-24-75ORDINANCE NO. 233-1 AN ORDINANCE AMENDING CHAPTER 23, SECTIONS 23-88, 23-91, 23-118 (C), 23-119, 23-129 OF THE CODE OF ORDINANCES, CITY OF PEARLAND, TEXAS, BY ADDING AND DELETING SPECIFIC PRO- VISIONS CONTAINED THEREIN, AND PROVIDING AN EFFECTIVE DATE. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF PEARLAND, TEXAS: SECTION I. That Section 23-88, Chapter 23 of the Code of Ordinances, City of Pearland, Texas, be and the same is hereby amended to read as follows: "Sec. 23-88. Waste, vent stack for water closet. Every building containing no more than two (2) water 'closets may use one three (3") inch waste and vent stack which shall continue full size to at least twelve (12") inches above the roof and not less than ten (10') feet above the ground. Every building containing more than two (2) water closets shall have at least one four (4") inch waste and vent stack, and shall continue its full size at least twelve (12") inches above the roof and not less than ten (10') feet above the ground. SECTION II. That Section 23-91, Chapter'23 of the Code of Ordinances, City of Pearland, Texas, be and the same is hereby amended to read as follows: "Sec. 23-91. Cleanout fittings and house drain. A four (4") inch cleanout plug fitting must be on the house drain two (2') feet outside the building brought up flush with the top of the ground and visible. Sink' cleanouts must be exposed on the outside wall. No tapped tees shall be used as cleanout fittings. House drain shall be four (4") inches minimum diameter. SECTION III. That Section 23-118 (C), Chapter 23 of the Code of Ordinances, City of Pearland, Texas be and the same is hereby amended to read as follows: "Sec. 23-118,(C). Service line, stop and waste, and house piping. The service line from meter to structure must be sized to furnish enough water to each fixture without having a pressure drop." Minimum size pipe 3/4" copper or plastic. Plastic pipe must conform to ASTM standards of schedule 40 or better PVC. The service beyond the stop and waste shall be 3/4" galvanized or copper, type L hard or soft drawn, or approved PVC pipe to the bathroom and not more than three (3) fixtures shall be supplied off a 1/2" pipe. All hot water pipe shall be a 3/4" galvanized, copper, or approved CPVC from heater to bath. Water service and other underground pipe shall be buried at least twelve (12" ) inches to a point at side of slab or just under building than may rise and be strapped to sills or floors joist securely at proper intervals.: Each fixture shall be controlled with a stop above the floor. SECTION IV. That Section 23-119, Chapter 23 of the Code of Ordinances, City of Pearland, Texas, be and the same is hereby amended to read as follows: "Sec. 23-119. Basic specifications fez. fittings. A11 fitting used in the water supply system shall be galvanized malleable iron fitting, galvanized cast iron fittings, brass fittings, copper or cast brass sweat fittings or approved PVC and CPVC fillings. All connections and branches on lead services must be made by means of plumber's wiped joints. No pipes of fittings that have been used for other purposes shall be used for distributing water. SECTION V. That Section 23-129, Chapter 23 of the Code of Ordinances, City of Pearland, Texas, be and the same is hereby amended to read as follows: ae4cn, ption Item "Sec. 23-129. to apply where Specifications for plumbing materials indicated in sections of this Code. Acothm ty ANSI ASYM FS Rematko on othejr. btandanda Nonmetallic pipe: Clay sewer pipe Clay sewer pipe Clay sewer pipe Clay sewer pipe Polyvinyl Chloride Plastic PVC SDR 33.5 Acrylonitrile butadiene Styrene ABS C 261 60 T C 271 60 T C 13 57 T C 200 57 T D 2665 68 D 3033 34 D 2661 67 ABS composite sewer pipe D 2680 68T Asbestos cement sewer pipe SS P 351a 53 Unglazed stan. strength Unglazed stan. strength Standard strength Extra strength CS 272 65 House drain only CS 270 65 polyethylene ultra high molecular weight plastic water service pipe 160 psi polyvinyl chloride pipe PVC 1120 Schedule 40 Type I Chlorinated polyvinyl Chloride CPVC SDR11 D 2239 69 D 1248 70a 3 C 5 P 34 D 1784 69 D 2467 PS 11 69 Produce standards PS 21 70 Hot and cold water two inch maximum SECTION VI. It is the intention of the City Council, and it is ordained, that the provisions of this ordinance shall become and be made a part of the Code of Ordinances, City of Pearland, Texas. SECTION VII. This ordinance shall take effect and be in full force and effect from and after its adoption on second and final reading. PASSED and APPROVED on first reading at a regular Session of the City Council this Bv: day of a?l,_— _p CITY OF PEARLAND, TEXAS 9 u A.D. 1975. � ditp7,1 Carlton McComb Mayor PASSED, APPROVED and ADOPTED on second and final reading at a regular Session of the City Council this day of A. D. 1975. BY: ATTEST: Dorothy L. Cook City Secretary APPROVED AS TO FORM: Bobby Williams City Attorney Effective Date: CITY OF PEARLAND, TEXAS Carlton McComb Mayor - 3 -