Loading...
Ord. 0115B 1968-07-25AMENDMENT ORDINANCE NO. 115B AN ORDINANCE AMENDING THE PEARLAND PLUMBING CODE, ORDINANCE NUMBEti 115-B, HERETOFORE PASSED BY THE CITY OF PEARLAND, BRAZORIA COUNTY, TEXAS, SUCH AMENDMENT PROVING THAT THE CITY OF PEARLAND CAN PROVIDE CERTAIN SPECIFICATIONS FOR PLUMBING INSTALLATIONS AND SPECIFICATIONS FOR GAS PIPING AND GAS APPLIANCES ON CERTAIN PROPERTIES AND PROPERTY OWNERS AND DECLARING AN EMERGENCY: WHEREAS, Ordinance Number 115- , of the City of Pearland, Brazoria County, Texas, being the Plumbing Code, does not provide adequate specifications for plumbing installations and for gas piping and gas appliances in construction of certain buildings and residence. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF PEARLAND, TEXAS: That said Ordinance Number 115-B is hereby amended as follows: ARTICT,R IV SECTION 2: SPECIFICATIONS FOR PLUMBING INSTALLATIONS (9-A) Cast Iron Soil Pipe and Fittings for soil, waste, vent conductors, building drains or sewers, tar -coated unless otherwise specified, shall conform to Cs-188 or comparative standards. Joints for Cast Iron soil pipe and fittings with hubs and beaded spigots shall be made with caulked lead and oakum as specified in Chapter 4, ASA A40.8;° Joints for cast iron soil pipe and fittings with hubs and plain end spigots shall be made with caulked lead and oakum as specified in Chapter 4, ASA A40.8-;, or by using positive double -sealed elastomeric compression - type gaskets-:-, conforming to ASTM C 564. Service pipe CJG/cfp 7-24-68 shall be joined with service gaskets and extra heavy pipe with extra heavy gaskets. * Caulked joints - caulked joints for cast-iron bell and spigot soil pipe shall be firmly packed with oakum or hemp and filled with molten lead not less than one inch deep', and not to extend more than 1/8 inch below rim of hub. No paint, varnish, or other coating shall be permitted on the jointing material until after the joint has been tested and approved. ** Positive double -sea; elastomeric compression - type joints are joints which are sealed by deformation of a one-piece double -seal gasket. When the joint is made, a positive seal is effected by the compression of the elastomer between the external face of the spigot and the internal face of the hub. ARTICLE IV SECTION 18 SPECIFICATIONS FOR PLUMBING INSTALLATIONS (44-A) There shall be a T-handle roundway stop and waste 3/4 or larger, at least six (6") inches above ground at the structure to control all water in building. The plumber to furnish coupling at meter side of stop. The service line from meter to structure must be sized to furnish enough water to each fixture without having a pressure drop. Minimum size pipe 3/4 " copper or plastic. Plastic pipe must conform to A.S.T.M. standards of schedule 40 or better P.V.C. The service beyond the stop and waste shall be 3/4 " galvanized or copper, type L hard or soft drawn pipe to the bathroom and not more than three (3) fixtures shall be supplied off a half -inch pipe. All hot water pipe shall be a 3/4 " galvanized or copper from heater to bath. Water service and other underground pipe shall be buried at least twelve inches (12") to a point CJG/cfp 7-24-68 at side of slab or just under building then may rise and be strapped to sills or floor joist securely at proper intervals. Each fixture shall be controlled with a stop above floor. ARTICLE V SECTION 19 SPECIFICATIONS FOR GAS PIPING AND GAS APPLIANCES (10) No underground yard or service line hereinafter installed shall be less than one (1) inch pipe, to be coated and wrapped per A-1 specifications. All underground fittings to be wrapped accordingly, and the take -off on the house side of the meter may be not less than one (1") inch to the heating unit. Branch lines for ranges or cook stoves shall be not less than three-quarter (3/4") inch and shall be furnished with a master lever handle stop. Risers or branch lines of one-half (1/2") inch pipe shall not be more than ten (10) feet in length. Lead piping must not be used under any circumstances. No bushings shall be installed in gas fittings. Unions except for connecting cook stoves or other appliances shall be avoided and no gasket union will be allowed on gas connection of any kind. All gas pipe must be properly reamed and the inside free from obstruction before being put in use. All house lines must be strapped securely to joists every eight (8`) feet and at the end of each branch. Gas pipe shall not be CJG/cfp 7-24-68 installed in or under a concrete floor slab. AND DECLARING AN EMERGENCY. This amendment PASSED and APPROVED on this the 2 day of ATTEST: \� 'CITY SECRETARR 1968. CITY OF PEARLAND, TEXAS BY: