Loading...
HomeMy WebLinkAboutR2026-168 20261026RESOLUTION NO. R2026-168 A Resolution of the City Council of the City of Pearland, Texas, authorizing the City Manager or his designee to enter into a contract with LJA, Inc., in the amount of $893,929.00, for professional services associated with the Alice Elevated Storage Tank and Ground Storage Tank Project (WA2601) and the Alice Water Treatment Plant New 5 MG Ground Storage Tank Project (WA2609). BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF PEARLAND, TEXAS: Section 1. That certain contract by and between the City of Pearland and LJA, Inc., a copy of which is attached hereto as Exhibit “A” and made a part hereof for all purposes, is hereby authorized and approved. Section 2. That the City Manager or his designee is hereby authorized to execute and the City Secretary to attest a contract with LJA, Inc., for professional services associated with the Alice Elevated Storage Tank and Ground Storage Tank Project (WA2601) and the Alice Water Treatment Plant New 5 MG Ground Storage Tank Project (WA2609). PASSED, APPROVED and ADOPTED this on the 26th day of October, A.D., 2026. ________________________________ QUENTIN WILTZ MAYOR ATTEST: ________________________________ FRANCES AGUILAR, TRMC, MMC CITY SECRETARY APPROVED AS TO FORM: ________________________________ LAWRENCE G. PROVINS CITY ATTORNEY Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Professional Services Contract 1 of 5 4/2019 CONTRACT FOR PROFESSIONAL SERVICES THIS CONTRACT is entered into upon final execution by and between the City of Pearland ("CITY") and LJA, Inc. ("CONSULTANT"). The CITY engages the CONSULTANT to perform professional services for a project known and described as Alice Elevated & Ground Storage Tank Replacement and Alice 5MG GST ("PROJECT"). (Project # WA2601, WA2609), Contract # P121-26. SECTION I - SERVICES OF THE CONSULTANT The CONSULTANT shall perform the following professional services to CITY standards and in accordance with the degree of care and skill that a professional in Texas would exercise under the same or similar circumstances: A. The CONSULTANT shall provide professional services. See Exhibit A, attached, for a detailed SCOPE OF WORK and PROJECT schedule. The PROJECT schedule shall be submitted in digital and hard copy form in the Microsoft Project for Windows format. B.The CONSULTANT shall prepare and submit a detailed opinion of estimated cost of the PROJECT. C.The CONSULTANT acknowledges that the CITY (through its employee handbook) considers the following to be misconduct that is grounds for termination of a CITY employee: Any fraud, forgery, misappropriation of funds, receiving payment for services not performed or for hours not worked, mishandling or untruthful reporting of money transactions, destruction of assets, embezzlement, accepting materials of value from vendors, or consultants, and/or collecting reimbursement of expenses made for the benefit of the CITY. The CONSULTANT agrees that it will not, directly or indirectly; encourage a CITY employee to engage in such misconduct. D.The CONSULTANT shall submit all final construction documents in both hard copy and electronic format. Plans shall be AutoCAD compatible and all other documents shall be Microsoft Office compatible. The software version used shall be compatible to current CITY standards. Other support documents, for example, structural calculations, drainage reports and geotechnical reports, shall be submitted in hard copy only. All Record Drawings electronic files shall be submitted to the CITY in TIF format. E.The CONSULTANT recognizes that all drawings, special provisions, field survey notes, reports, estimates and any and all other documents or work product generated by the CONSULTANT under the CONTRACT shall be delivered to the CITY upon request, shall become subject to the Open Records Laws of this State. EXHIBIT A Resolution No. R2026-168Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Professional Services Contract 2 of 5 4/2019 F. The CONSULTANT shall procure and maintain for the duration of this Agreement, insurance against claims for injuries to persons, damages to property, or any errors and omissions relating to the performance of any work by the CONSULTANT, its agents, employees or subcontractors under this Agreement, as follows: (1) Workers’ Compensation as required by law. (2) Professional Liability Insurance in an amount not less than $1,000,000 in the aggregate. (3) Comprehensive General Liability and Property Damage Insurance with minimum limits of $1,000,000 for injury or death of any one person, $1,000,000 for each occurrence, and $1,000,000 for each occurrence of damage to or destruction of property. (4) Comprehensive Automobile and Truck Liability Insurance covering owned, hired, and non-owned vehicles, with minimum limits of $1,000,000 for injury or death of any one person, $1,000,000 for each occurrence, and $1,000,000 for property damage. The CONSULTANT shall include the CITY as an additional insured under the policies, with the exception of the Professional Liability Insurance and Workers’ Compensation. Certificates of Insurance and endorsements shall be furnished to the CITY before work commences. Each insurance policy shall be endorsed to state that coverage shall not be suspended, voided, canceled, and/or reduced in coverage or in limits (“Change in Coverage”) except with prior written consent of the CITY and only after the CITY has been provided with written notice of such Change in Coverage, such notice to be sent to the CITY either by hand delivery to the City Manager or by certified mail, return receipt requested, and received by the City no fewer than thirty (30) days prior to the effective date of such Change in Coverage. Prior to commencing services under this CONTRACT, CONSULTANT shall furnish CITY with Certificates of Insurance, or formal endorsements as required by this CONTRACT, issued by CONSULTANT’S insurer(s), as evidence that policies providing the required coverage, conditions, and limits required by this CONTRACT are in full force and effect. G. The CONSULTANT shall indemnify and hold the CITY, its officers, agents, and employees, harmless from any claim, loss, damage, suit, and liability of every kind for which CONSULTANT is legally liable, including all expenses of litigation, court costs, and attorney's fees, for injury to or death of any person, for damage to any property, or errors in design, any of which are caused by the Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Professional Services Contract 3 of 5 4/2019 negligent act or omission of the CONSULTANT, his officers, employees, agents, or subcontractors under this CONTRACT. H. All parties intend that the CONSULTANT, in performing services pursuant to this CONTRACT, shall act as an independent contractor and shall have control of its own work and the manner in which it is performed. The CONSULTANT is not to be considered an agent or employee of the CITY. SECTION II - PERIOD OF SERVICE This CONTRACT will be binding upon execution and end March 31, 2029. SECTION III - CONSULTANT'S COMPENSATION A. The total compensation for the services performed shall not exceed the total noted in Section B. B. The CITY shall pay the CONSULTANT in installments based upon monthly progress reports and detailed invoices submitted by the CONSULTANT based upon the following: 1. Basic Services (Lump Sum) $734,676.00 2. Additional Services shall require independent and specific authorization and shall be billed as (Lump Sum): $159,253.00 3. Bid Phase Services (Hourly Not to Exceed) 4. Construction Phase Services (Hourly Not to Exceed) 5. Reimbursable Expenses (Not to Exceed) 6. Total: $893,929.00 C. The CITY shall make payments to the CONSULTANT within thirty (30) days after receipt and approval of a detailed invoice. Invoices shall be submitted on a monthly basis. SECTION IV - THE CITY'S RESPONSIBILITIES A. The CITY shall designate a project manager during the term of this CONTRACT. The project manager has the authority to administer this CONTRACT and shall monitor compliance with all terms and conditions stated herein. All requests for information from or a decision by the CITY on any aspect of the work shall be directed to the project manager. B. The CITY shall review submittals by the CONSULTANT and provide prompt response to questions and rendering of decisions pertaining thereto, to minimize Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Professional Services Contract 4 of 5 4/2019 delay in the progress of the CONSULTANT'S work. The CITY will keep the CONSULTANT advised concerning the progress of the CITY'S review of the work. The CONSULTANT agrees that the CITY'S inspection, review, acceptance or approval of CONSULTANT'S work shall not relieve CONSULTANT'S responsibility for errors or omissions of the CONSULTANT or its sub-consultant(s) or in any way affect the CONSULTANT’S status as an independent contractor of the CITY. SECTION V - TERMINATION A. The CITY, at its sole discretion, may terminate this CONTRACT for any reason - - with or without cause -- by delivering written notice to CONSULTANT personally or by certified mail at 11821 East Freeway, Suite 360 Houston, TX. 77029. Immediately after receiving such written notice, the CONSULTANT shall discontinue providing the services under this CONTRACT. B. If this CONTRACT is terminated, CONSULTANT shall deliver to the CITY all drawings, special provisions, field survey notes, reports, estimates and any and all other documents or work product generated by the CONSULTANT under the CONTRACT, entirely or partially completed, together with all unused materials supplied by the CITY on or before the 15th day following termination of the CONTRACT. C. In the event of such termination, the CONSULTANT shall be paid for services performed prior to receipt of the written notice of termination. The CITY shall make final payment within sixty (60) days after the CONSULTANT has delivered to the CITY a detailed invoice for services rendered and the documents or work product generated by the CONSULTANT under the CONTRACT. D. If the remuneration scheduled under this contract is based upon a fixed fee or definitely ascertainable sum, the portion of such sum payable shall be proportionate to the percentage of services completed by the CONSULTANT based upon the scope of work. E. In the event this CONTRACT is terminated, the CITY shall have the option of completing the work, or entering into a CONTRACT with another party for the completion of the work. F. If the CITY terminates this CONTRACT for cause and/or if the CONSULTANT breaches any provision of this CONTRACT, then the CITY shall have all rights and remedies in law and/or equity against CONSULTANT. Venue for any action or dispute arising out of or relating to this CONTRACT shall be in Brazoria County, Texas. The laws of the State of Texas shall govern the terms of this CONTRACT. The prevailing party in the action shall be entitled to recover its actual damages with interest, attorney’s fees, costs and expenses incurred in connection with the dispute and/or action. CONSULTANT and CITY desire an expeditious means to resolve any disputes that may arise between under this Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 5 of 5 4/2019 CONTRACT. To accomplish this, the parties agree to mediation as follows: If a dispute arises out of or relates to this CONTRACT, or the breach thereof, and if the dispute cannot be settled through negotiation, then the parties agree first to try in good faith, and before pursuing any legal remedies, to settle the dispute by mediation of a third party who will be selected by agreement of the parties. SECTION VI – ENTIRE AGREEMENT This CONTRACT represents the entire agreement between the CITY and the CONSULTANT and supersedes all prior negotiations, representations, or contracts, either written or oral. This CONTRACT may be amended only by written instrument signed by both parties. SECTION VII – COVENANT AGAINST CONTINGENT FEES The CONSULTANT affirms that he has not employed or retained any company or person, other than a bona fide employee working for the CONSULTANT to solicit or secure this CONTRACT, and that he has not paid or agreed to pay any company or person, other than a bona fide employee, any fee, commission, percentage brokerage fee, gift, or any other consideration, contingent upon or resulting from the award or making of the CONTRACT. For breach or violation of this clause, the CITY may terminate this CONTRACT without liability, and in its discretion, may deduct from the CONTRACT price or consideration, or otherwise recover, the full amount of such fee, commission, percentage brokerage fee, gift, or contingent fee that has been paid. SECTION VIII- SUCCESSORS AND ASSIGNS This CONTRACT shall not be assignable except upon the written consent of the parties hereto. DATE DATE ________________________________ ASSISTANT FINANCE DIRECTOR CITY OF PEARLAND, TEXAS ________________________________ CITY MANAGER/DIRECTOR CITY OF PEARLAND, TEXAS ________________________________ CONSULTANT Professional Services Contract DATE 09/08/26Jimmy Flowers, PE - Vice President Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 11/4/2026 | 8:47 AM CST 11/4/2026 | 8:26 AM CST ATTEST: ________________________________ FRANCES AGUILAR, TRMC, MMC CITY SECRETARY Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 September 8, 2026 Ms. Lori Bender Senior Project Manager Engineering & Public Works City of Pearland 2016 Old Pearland Road Pearland, Texas 77581 Re: Proposal for Design and Construction Related Services for the WA2601 – Alice Elevated and Ground Storage Tank Rehabilitation and WA2609 – Alice Water Treatment Plant New 5-Million-Gallon Ground Storage Tank for the City of Pearland LJA Proposal No. 0000022236 Dear Ms. Bender: LJA, Inc. (LJA) is pleased to submit this proposal to provide design and construction related services associated with the WA2601 – Alice Elevated and Ground Storage Tank Rehabilitation and the WA2609 – Alice Water Treatment Plant New 5 MG Ground Storage Tank for the City of Pearland. The Alice Water Treatment Plant (WTP) was built in the 1980s, with a 500,000-gallon elevated storage tank (EST). In 2010, the facility was expanded to add a 5-million-gallon (MG) ground storage tank (GST), three booster pumps, and a 750-kilowatt (kW) emergency generator. The original 2010 plan also reserved space for a second 5-MG GST and an additional booster pump to support anticipated demand growth in Pearland’s east service area. WA2601 – Alice Elevated and Ground Storage Tank Rehabilitation: The Texas Commission on Environmental Quality (TCEQ) requires annual inspections of all water storage tanks. The July 2025 inspection found that while the existing EST and GST remain operational, their interior and exterior coatings have exceeded their typical service life. To maintain regulatory compliance and extend asset longevity, replacement of coatings, electrical components, venting, piping, and the City logo is recommended. WA2609 – Alice Water Treatment Plant New 5-Million-Gallon Ground Storage Tank: The original WTP layout was designed to accommodate a future second 5-MG GST and booster pump. Constructing this additional tank will increase potable water storage capacity, improve system reliability, support peak-demand conditions, and reduce dependence on external water sources. SCOPE OF CONTRACT/AGREEMENT Projects WA2601 and WA2609 have been combined into a single design and construction package. This approach streamlines coordination and minimizes operational disruptions when the existing GST is taken offline for rehabilitation. WA2601 – Rehabilitation Scope: LJA will prepare construction documents for the rehabilitation of existing EST and GST. Planned Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Ms. Lori Bender City of Pearland September 8, 2026 Page 2 of 8 H:\Engineering\Proposals\City of Pearland\City of Pearland - Assignment Letter - WA2601&WA2609 Alice EST & GST Rehab - New 5MG GST - REV 2026-09-08.docx improvements include replacement of interior and exterior coatings, upgrades to the electrical and vent systems, and piping repairs. Both tanks will be equipped with mixers to eliminate thermal stratification and improve water quality. LJA will provide full design, bidding, and construction-phase services. WA2609 – Alice WTP New 5-MG GST Scope: LJA will design and prepare construction documents for a new 5-MG concrete GST equipped with a mixer. The project also includes installation of a new booster pump, replacement of three existing pumps, and evaluation of electrical and generator capacity for potential upgrades. LJA will provide full design, bidding, and construction-phase services. SCOPE OF SERVICES A. Basic Services (Design) 1. 60% Design Phase a. Attend Preliminary Conference with the City and other interested parties regarding the project. Provide a detailed design schedule from Notice to Proceed (NTP) through bidding completion for the project, including submittal dates, review times, Texas Commission on Environmental Quality (TCEQ) approvals, bidding and award. b. Review all reports/plans regarding the existing water plant and tanks planned for rehabilitation. c. Establish the scope of any topographical surveys which, in the opinion of the Engineer, may be required. Coordinate mobilization of survey crews and incorporate detailed topographic survey into the proposed civil site plans. d. Coordinate the geotechnical investigations to ensure adequate bores are completed in accordance with American Concrete Institute requirements. Incorporate findings and recommendations from the geotechnical reports into the proposed plans and specifications. e. Review and determine if the existing generator is sized to handle the existing electrical load and proposed electrical load. f. Review and determine if the existing electrical room and control room is of sufficient size to accommodate the additional Variable Frequency Drives (VFD) and control panel, as well as if the existing HVAC system is sufficient for the additional heat load generated by the additional electrical equipment. g. Coordinate with electrical engineer to provide memorandum of understanding with findings and recommendations regarding the generator and electrical room early in the 60% Design Phase. h. Prepare preliminary site layout for discussions with the City and to gain their approval early in the 60% Design Phase. Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Ms. Lori Bender City of Pearland September 8, 2026 Page 3 of 8 H:\Engineering\Proposals\City of Pearland\City of Pearland - Assignment Letter - WA2601&WA2609 Alice EST & GST Rehab - New 5MG GST - REV 2026-09-08.docx i. Coordination with Brazoria Drainage District No. 4 (BDD4) with regards to Drainage/Detention Requirements. j. Prepare draft detention/drainage calculations and show on site plan. k. Review of existing Electrical and Controls for space and capacity needs, coordination with CenterPoint Energy (CPE) as needed. l. Prepare detailed structural sheets required for establishing minimum standards for the tank manufacturers to adhere to. m. Prepare detailed electrical sheets illustrating any modifications to the electrical equipment, conduits, and controls to ensure the tank can be placed online, monitored, and integrated into the City’s infrastructure and SCADA systems. n. Prepare detailed civil and mechanical sheets illustrating any site modifications required to construct the tank, modifications to the yard piping needed to place the tank online, removal of the existing booster pumps, and the installation of four new booster pumps. o. Prepare and submit 60% submittal for City review, including Construction Plans and Opinion of Probable Construction Cost (OPCC). p. Prepare detailed specifications, contract documents, and contract drawings. q. Coordination with BDD4 on drainage / detention requirements as necessary. 2. 90% Design Phase a. Address City comments from 60% submittal and review. b. Continue the design of detailed structural sheets required for establishing minimum standards for the tank manufacturers to adhere to. c. Continue the design of detailed electrical sheets illustrating any modifications to the electrical equipment, conduits, and controls to ensure the tank can be placed online, monitored, and integrated into the City’s infrastructure and SCADA systems. d. Continue the design of detailed civil and mechanical sheets illustrating any site modifications required to construct the tank, modifications to the yard piping needed to place the tank online, removal of the existing booster pumps, and the installation of four new booster pumps. e. Continue the preparation of detailed specifications, contract documents, and contract drawings. f. Prepare and submit 90% submittal for City review, including Construction Plans and OPCC. g. Submit final contract specifications and drawings to the required agencies for review and approval. Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Ms. Lori Bender City of Pearland September 8, 2026 Page 4 of 8 H:\Engineering\Proposals\City of Pearland\City of Pearland - Assignment Letter - WA2601&WA2609 Alice EST & GST Rehab - New 5MG GST - REV 2026-09-08.docx 3. Final 100% Design Phase a. Address City comments from 90% submittal and review. b. Finalize contract drawings and prepare detailed specifications and contract documents. c. Submit final contract documents to corresponding regulatory agencies (such as TCEQ) for review and approval, in order to receive approvals and permits if required. 4. Deliverables and Schedule for Each Phase a. Provide memorandum of understanding from electrical engineer with findings and recommendations regarding the generator requirements within 28 Calendar Days of NTP. b. 60% Design Phase: 60% plans, specs, project manual, OPCC, estimated construction schedule, and updated design schedule to be submitted approximately 109 Calendar Days after kick-off meeting and NTP. c. 90% Design Phase: 90% plans, specs, project manual, OPCC, estimated construction schedule, updated design schedule, and comment response log to be submitted approximately 81 Calendar Days after receipt of 60% comments. d. Final 100% Design Phase: final plans, specs, project manual, OPCC, estimated construction schedule, and comment response log to be submitted approximately 70 Calendar Days after receipt of 90% comments. e. At every design phase, submit documents and coordinate with City permitting department (City of Pearland Community Development Department) and any other external regulatory agency (such as TCEQ), as required for the completion of this project to ensure City permitting requirements are met. f. Maintain an Action Tracker for the duration of the project. B. Bidding Phase 1. Assist the City in the advertisements of the project for bids. 2. Respond to questions regarding the project during the bidding process. If required, issue addendums to clarify any questions regarding the project. 3. Conduct a Pre-Bid Conference between the Engineer, City, prospective bidders, suppliers, etc., to make certain that the scope of the work is fully understood. 4. Evaluate bids, check Contractor financial standing and references, and prepare a recommendation letter for Council action. a. Bid evaluation to include the following: i. Check for math errors and reconcile any mathematical discrepancies. Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Ms. Lori Bender City of Pearland September 8, 2026 Page 5 of 8 H:\Engineering\Proposals\City of Pearland\City of Pearland - Assignment Letter - WA2601&WA2609 Alice EST & GST Rehab - New 5MG GST - REV 2026-09-08.docx ii. Review for unbalanced bid items. iii. Provide certified Bid Tabulation including Engineer’s estimate. b. Review of contractor’s financial standing and references to include the following: i. Detailed summary of the client call, outlining participant roles, questions raised, and responses provided. c. Recommendation of award to include the following: i. Explanation of discrepancies between the Engineer provided OPCC and bids received. 5. Attend City Council Meeting and make recommendation for award of Contract. 6. Prepare final contract documents for execution by the Contractor and the City. C. Construction Phase 1. Conduct a Pre-Construction Conference between the City, Engineer, and Contractor. 2. Issue a work order with dates approved by the City. 3. Make periodic visits to the project site to observe work with regard to general compliance with the plans and specifications. 4. Review, comment, and accept Contractor’s submittals, Requests for Information (RFIs), and Requests for Proposals (RFPs), including coordination with City Project Manager on Change Directives and Change Orders. 5. Preparation for execution of the necessary progress documents including work order, payment estimates (after City Inspector has reviewed and approved the quantity of installed items), change orders, time extensions, and other correspondence required to achieve the intended finished project. 6. Provide interpretive guidance for the Contractor and City Project Manager to assist in resolving issues that might arise. 7. Coordinate with City Project Manager and/or Construction Inspector to (a) review progress of work for Substantial Completion; (b) Substantial Completion walk through and produce the punch list; (c) confirm that the punch list items are completed at a final completion walk through; and (d) issue both Certificate of Substantial Completion and Final Acceptance. 8. Issue letter to the City recommending acceptance, based upon City Inspector observations, and release of final payment. 9. Upon completion of the project, the contract drawings will be revised to reflect all field changes. The completed “record drawings” will be delivered to the Owner. Record Drawings to be supplied to the City in PDF and AutoCAD formats. Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Ms. Lori Bender City of Pearland September 8, 2026 Page 6 of 8 H:\Engineering\Proposals\City of Pearland\City of Pearland - Assignment Letter - WA2601&WA2609 Alice EST & GST Rehab - New 5MG GST - REV 2026-09-08.docx D. Additional Services 1. Additional Design Phase Services (New Generator) with Written Authorization: a. Provide additional design phase services to incorporate a new generator into the proposed design. b. Provide additional electrical design services to incorporate a new generator into the proposed design. 2. Additional Construction Phase Services (New Generator) if Generator Design is Authorized: a. Provide additional construction phase services to incorporate a new generator into the proposed construction. b. Provide additional electrical design assistance in construction phase to incorporate a new generator into the proposed construction. 3. Topographical Surveys: Provide field surveys of existing structures, lines, site conditions, and other features required for the preparation of final construction. 4. Geotechnical Investigations: Provide field investigations of the geotechnical conditions to determine design. Determine groundwater conditions and need for dewatering during construction. 5. Landscape Architecture Services: Upon receipt of written authorization, LJA Landscape Architecture will provide landscape architecture and irrigation design services for the Alice Street Water Plant, including the preparation of permit and construction-ready documentation in accordance with City of Pearland requirements. Services include development of planting and irrigation plans, technical details, plant schedules, specifications, and coordination with project consultants to deliver a cohesive and constructible design. Project deliverables will include a 90% Planting and Irrigation Plan submittal, a 100% Construction Document package, an Issue for Bid (IFB) package, and an Issue for Construction (IFC) package. Documents will be prepared under the supervision of a registered Professional Landscape Architect, with coordination and permit support provided as necessary to facilitate agency review and project implementation. 6. Project Representative: It is our understanding the City will provide all required on-site project inspection services, and the services of an AMPP / NACE Int. Certified Coatings Inspector, so a project representative is not included in the scope of this project. 7. Conditions Assessment of Existing Tanks: It is our understanding the City will provide all required conditions assessments, so assessments of the existing tanks are not included in the scope of this project. Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Ms. Lori Bender City of Pearland September 8, 2026 Page 7 of 8 H:\Engineering\Proposals\City of Pearland\City of Pearland - Assignment Letter - WA2601&WA2609 Alice EST & GST Rehab - New 5MG GST - REV 2026-09-08.docx BASIS OF COMPENSATION For the accomplishment of the above tasks and additional services, we propose that our compensation be based on the Scope of Services for each Phase and include a combination of Time and Materials and Lump Sum Fees. According to the City’s published FY2025-2030 CIP, the preliminary opinion of probable construction costs for the Alice Elevated and Ground Storage Tank Rehabilitation project and the Alice Water Treatment Plant New 5 MG Ground Storage Tank project are approximately $1,301,000.00 and $6,350,000.00, respectively, for a combined total of $7,651,000. With the additional mechanical and electrical scope (booster pumps, VFDs/controls, etc.) the pre-design OPCC is approximately $8,851,000.00 without contingencies. If it is determined a new generator is required to support the additional electrical load, the pre-design OPCC would be approximately $9,601,000.00 without contingencies. CURRENT AUTHORIZATION Basic Services Phase Description Contract Type FEE WA2601-903A1 60% Design Phase Lump Sum $ 45,629.00 WA2601-903B1 90% Design Phase Lump Sum $ 23,002.00 WA2601-903C1 Final 100% Design Phase Lump Sum $ 10,426.00 WA2601-904A Bidding Phase Lump Sum $ 5,752.00 WA2601-905A Construction Phase Lump Sum $ 23,310.00 WA2609-903A2 60% Design Phase Lump Sum $ 302,449.00 WA2609-903B2 90% Design Phase Lump Sum $ 152,991.00 WA2609-903C2 Final 100% Design Phase Lump Sum $ 53,634.00 WA2609-904B Bidding Phase Lump Sum $ 25,601.00 WA2609-905B Construction Phase Lump Sum $ 91,882.00 Sub-Total Basic Services $ 734,676.00 Additional Services Phase Description Contract Type FEE WA2609-903D2 Add’l. Design Phase (New Gen) Lump Sum $ 72,870.00 WA2609-905B1 Add’l. Constr. Phase (New Gen) Lump Sum $ 8,688.00 WA2609-905B2 Add’l. Elec. Asst. Constr. (New Gen) Lump Sum $ 2,100.00 WA2609-917 Landscape Architecture T&M $ 14,770.00 WA2609-925 Topographic Surveys T&M (Actual Cost + 5%) $ 18,900.00 WA2609-926 Geotechnical Investigations T&M (Actual Cost + 5%) $ 41,925.00 Sub-Total Additional Services $ 159,253.00 TOTAL CURRENT AUTHORIZATION $ 893,929.00 If the above Scope of Services and Basis of Compensation are satisfactory to you, your acceptance in the space provided below and a City issued Contract for Professional Services will be sufficient authorization to immediately commence the stated work. Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Ms. Lori Bender City of Pearland September 8, 2026 Page 8 of 8 H:\Engineering\Proposals\City of Pearland\City of Pearland - Assignment Letter - WA2601&WA2609 Alice EST & GST Rehab - New 5MG GST - REV 2026-09-08.docx On behalf of the project team, LJA appreciates this opportunity to provide Professional Engineering Services on this important project. Please do not hesitate to contact me should you have any questions or need additional information at 713.657.6013 or jflowers@lja.com. Sincerely, Proposal Accepted By: CITY OF PEARLAND Jimmy C. Flowers, PE By: Vice President Name: JCF/msc Date: Enclosure(s) Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 9711 S. Mason Rd. Suite 125 PMB 326 Richmond, Texas 77407 (281) 529-5005 TBPE Firm No. 16575 June 22, 2026 Jimmy Flowers, P.E. LJA Engineering, Inc. 3600 W. Sam Houston Pkwy S, Suite 600 Houston, Texas, 77042 Re: Professional Engineering Services Proposal for City of Pearland Alice Street Water Plant Expansion Brazoria County, Texas BGD Project No. 138-0059; Rev.1 Dear Jimmy: We appreciate the opportunity to present this proposal for electrical engineering services in connection with City of Pearland Alice Street Water Plant Expansion. Project Understanding The City of Pearland is expanding the existing Alice Street Water Plant. The scope of this project includes the addition of a 5MG ground storage tank, one (1) 200HP booster pump with Variable Frequency Drive (VFD), and one (1) mixer for the ground storage tank along with the associated control modifications. In addition, the existing three pumps and motors will be replaced. The three existing pumps include two pumps with existing VFDs which will remain, but the third pump has an existing SSRV starter and will be replaced with another VFD. All proposed VFDs will be “clean power” rated to reduce harmonics upstream of the VFDs. Based on the existing record drawing, we assume there is room in the existing electrical room for one (1) of the proposed VFDs, but it does not appear there is room for two (2) VFDs. We will look at other rooms or locate the VFD on the exterior of the building in an outdoor rated enclosure. In addition, we will evaluate the existing 750kW Diesel generator size and provide an alternate design and construction services fee if it needs to be replaced with larger generator for the additional motor load. Based on our understanding of your project, the review and approval process, we prepared the following scope of services and fee proposal for your consideration. Scope of Services A. Electrical Design Phase Services 1. Initial site visit to visually inspect existing conditions. 2. The electrical construction drawings shall include the following: a. Electrical site layout depicting location of electrical equipment and conduit routing. b. Electrical one-line diagram of the complete facility and load analysis specifying electrical equipment sizes. c. Conduit schedule specifying conductor and conduit sizes . d. Electrical control schematics for the proposed equipment. e. Electrical details. 3. Electrical Technical Specifications a. Division 13 & 16 specifications for electrical work and equipment required. Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Jimmy Flowers, P.E. Page 2 June 22, 2026 4. Deliverables a. 30% review set of drawings in electronic format (PDF). Limited to electrical site layout with major items of equipment/ductbank routing and one-line diagram. b. 60% review set for internal and agency reviews in electronic format (PDF). c. 100% signed and sealed construction drawings in electronic format (PDF). d. Electrical specifications in electronic format (PDF). 5. Items provided by Client a. AutoCAD drawings. i. Site layout ii. Border b. Load information including motor horsepower and/or equipment wattage of current and ultimate phase. c. Mechanical and process equipment specifications. 6. Attend one (1) design review meeting at Client’s office. B. Bidding Phase Services 1. Attend pre-bid meeting. 2. Respond to bidder questions through Client via phone and email. 3. Prepare addenda and revised plans as needed to correct errors and omissions or provide clarification. C. Construction Phase Services 1. Attend pre-construction meeting. 2. Review electrical shop drawings and submittals. 3. Review and comment on any Requests for Information (RFI). 4. One interim and one (1) final inspection at substantial completion and provide a punch list of observed electrical deficiencies. Additional site visits may be requested and shall be billed as an hourly service. 5. Interpret the intent of the plans via telephone or email. D. Additional Design Phase Services (Generator Replacement) 1. Generator sizing calculations. 2. Additional drawing modifications to site plan, one-line diagram, and conduits schedules and additional details. E. Additional Construction Phase Services (Generator Replacement) 1. Additional submittal reviews for generator, test reports, and O&Ms. Proposed Fee A. Electrical Design Phase Services (Lump Sum) = $30,000 B. Bid Phase Services (Lump Sum) = $1,000 C. Construction Phase Services (Lump Sum) = $8,000 D. Additional Design Phase Services (Lump Sum) = $20,000 E. Additional Construction Phase Services (Lump Sum) = $2,000 Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Jimmy Flowers, P.E. Page 3 June 22, 2026 Special Considerations This proposal is based on the following special considerations: 1. This proposal shall be subject to the Master Subconsultant Services Agreement dated December 21, 2020, between LJA Engineering, Inc. and Baird Gilroy & Dixon, LLC. 2. Civil design items including buildings, concrete slabs, drainage, and landscaping are not included. 3. Reimbursable expenses including outside services not performed by Baird Gilroy & Dixon, LLC personnel shall be provided and reimbursed at cost plus 10%. Although we do not anticipate any Reimbursable Expenses, these services typically include reproduction and deliveries. 4. Additional review meetings, construction site visits or other services desired by CLIENT may be provided by SUBCONSULTANT on an hourly basis or an agreed upon lump sum as an additional service to this contract as requested. 5. Hourly Services, if any, shall be provided in accordance with the Schedule of Hourly Rates listed below. This rate schedule may be revised upon written notification in January of each year. SCHEDULE OF HOURLY RATES Effective January 2026 Subject to Annual Revision in January 2027 Engineering Personnel Programming Personnel Electrical Engineer’s Assistant I $65 Programmer’s Assistant I $65 Electrical Engineer’s Assistant II $85 Programmer’s Assistant II $85 Electrical Staff Engineer $140 Programmer I $150 Electrical Project Engineer $160 Programmer II $170 Electrical Sr. Project Engineer $175 Programmer III $190 Electrical Project Manager $220 Programmer IV $210 Officer – Principal $265 Designer/Drafting Personnel Office Personnel CAD Operator I $85 Project Support Administrator $85 CAD Operator II $100 Accounting Manager $95 Designer I $115 Designer II $130 6. The proposed fees shall be considered in their entirety for the scope of services . Should you wish to contract with us for only a portion of the work, we reserve the right to negotiate individual scope items on their own merits. 7. Cost estimates prepared by the engineer represent their best judgment as a design professional familiar with the construction industry. It is recognized, however, that the engineer has no control over the cost of labor, materials, or equipment; over the contractor’s methods of determining bid prices; or over competitive bidding or market conditions. Accordingly, the engineer cannot and does not guarantee that bids will not vary from any cost estimate prepared by them. 8. This proposal shall be valid for sixty days from this date and may be extended upon approval by this office. Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Jimmy Flowers, P.E. Page 4 June 22, 2026 We appreciate the opportunity to submit this proposal and look forward to working with you . An executed copy of this proposal will serve as our notice to proceed. Please return one copy to our office. Should you have any questions, please call. Sincerely, Gregory S. Baird, P.E. Baird Gilroy & Dixon, LLC Principal P:\Projects\138\0059\Contracts\Proposal – City of Pearland Alice WP Expansion Rev.1.docx APPROVED BY: _______________________________________ Signature _______________________________________ Name and Title (Printed) _______________________________________ Date _______________________________________ LJA Engineering Inc. Project Number Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Proposal No. 1140744199 December 12, 2025 Mr. Jimmy Flowers, P.E. Vice President LJA Engineering, Inc. 2014 Airport Road, Suite 100 Conroe, Texas 77301 Re: Proposal for Geotechnical Investigation Proposed 5 MG Ground Storage Tank City of Pearland – Alice Water Treatment Plant Pearland, Texas Dear Mr. Flowers: As per your request, Geotest Engineering, Inc., is pleased to submit this proposal for the above referenced project. This project consists of the design and construction of a new 5-million gallons ground storage tank at the City of Pearland, Alice Water Treatment Plant in Pearland, Texas. The tank will be prestressed concrete tank and will be designed as per ACI 372R-13. Based on the information provided to us the inside diameter of the tank is about 156 feet with a water column height of 35 feet. Purpose and Scope The purposes of this study are to explore the subsurface conditions at the proposed site and develop geotechnical recommendations pertinent to the design and construction of the ground storage tank. The scope of the geotechnical services is based on information provided to us by email dated December 9, 2025. The scope of work consists of the following tasks: • Drill and sample ▪ one (1) 120-foot deep boring at the proposed tank center location and four (4) 60-foot deep borings equally spaced on the anticipated perimeter of the tank foundation. The exploration sampling and testing will be in accordance with ACI372R. The approximate boring locations are shown on Plan of Borings Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Mr. Jimmy Flowers, P.E. Proposal No. 1140744194 Page 2 December 12, 2025 presented on Figure 1. •Perform appropriate laboratory tests including consolidation on selected representative soil samples to determine the physical and strength properties and consolidation characteristics of the soils. •Perform engineering analyses to develop the geotechnical recommendations for the proposed ground storage tank per ACI372R-13, including foundation recommendation, over excavation, settlement analyses and site preparation and water level control and bedding and backfill for any pipe connections. •Prepare a geotechnical report including field and laboratory data, and engineering recommendations as outlined above. It is our understanding that your surveyors will tie-in our borings after completion of the drilling. Project Schedule We should be able to start the fieldwork within one week after receiving your written authorization or one week after staking the borings, whichever is latest. The fieldwork will be completed in about one (1) week, baring bad weather. The laboratory tests will be completed in about five (5) weeks. The geotechnical investigation report, which will include field and laboratory data and geotechnical recommendations, will be submitted in about ten (10) weeks after receiving the written authorization. Cost Based on the scope of services outlined above, the cost of the field investigation, laboratory testing, engineering analyses, and a final report will be a lump sum of $39,928.00. The cost breakdown given in Attachment No. 1 is for additional information only. The invoices will be billed on Lump Sum basis based on percent completion. This cost is based on the assumption that the site is accessible to a truck mounted drilling rig and no site clearance will be required. barring 1140744199 Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Mr. Jimmy Flowers, P.E. Proposal No. 1140744194 Page 3 December 12, 2025 We appreciate the opportunity to propose on this project. We hope this proposal meets your approval. Please sign on copy of this letter in the space below and return it to us along with your purchase order. If you have any questions, please contact us. Sincerely, GEOTEST ENGINEERING, INC. Naresh Kolli, P.E. Sr. Project Manager NK\ego Copies Submitted: (1-PDF) Attachment No. 1 PC38\Geotechnical\Proposals\40744199.DOC Figure 1 – Plan of Borings Attachment No. 1 – Cost Breakdown ACCEPTED BY: PRINTED NAME: TITLE: DATE: 1140744199 Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Project: 5 MG Ground Storage Tank Proposal No. 1140714199 Texas City, Texas Unit Mob and Demob of Truck Mounted Drilling Rig, Crew 1 LS $800.00 $800.00 Drilling and Continuous Sampling from 0 to 20 feet 100 ft.$25.00 $2,500.00 Drilling and Intermittent Sampling, from 20 to 50 ft.150 ft.$24.00 $3,600.00 Drilling and Intermittent Sampling, over 50 feet 110 ft.$28.00 $3,080.00 Drilling and Intermittent Sampling, over 100 feet, surcharge 20 ft.$15.00 $300.00 Field Coordination and Utility Clearance for Boring Locations 53 hrs $90.00 $4,770.00 Vehicle Charge (marking borings)18 hrs $11.00 $198.00 Cement Bentonite Grout 360 ft.$9.00 $3,240.00 Subtotal $18,488.00 Laboratory Testing Sieve Analysis through No. 200 sieve 8 ea.$58.00 $464.00 Moisture Content 66 ea.$11.00 $726.00 Percent Passing No. 200 sieve 28 ea.$52.00 $1,456.00 Specific Gravity 1 ea.$54.00 $54.00 Triaxial Compressive Strength, per Specimen or Stage: 36 ea.$65.00 $2,340.00 Consolidation including additional increments 1 ea.$650.00 $650.00 Subtotal $8,030.00 Engineering Analyses Sr. Engineer 15.0 hr.$210.00 $3,150.00 Staff Engineer 60.0 hr.$126.00 $7,560.00 Support Personnel (Drafting, Word Processing)15.0 hr.$80.00 $1,200.00 $13,410.00 Total Cost $39,928.00 COST BREAKDOWN ATTACHMENT NO. 1 PC38\Geotechnical\Proposals\40744199.xls\cost Pearland, Texas Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Geotest Engineering, Inc. Pr o p o s a l N o . 11 4 0 7 4 41 99 FIGURE 1 PROPOSED PLAN OF BORINGS Legend Geotest Engineering, Inc Proposed 5-MG Ground Storage Tank Alice WTP City of Pearland Proposed Boring Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 Geotest Engineering, Inc. Pr o p o s a l N o . 11 4 0 7 4 41 99 FIGURE 1 PROPOSED PLAN OF BORINGS Legend Geotest Engineering, Inc Proposed 5-MG Ground Storage Tank Alice WTP City of Pearland Proposed Boring Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 PROJECT FEE ESTIMATE City of Pearland WA2601 - Alice Elevated and Ground Storage Tank Rehabilitation and WA2609 - Alice Water Treatment Plant New 5-Million-Gallon Ground Storage Tank E042-TBD 9/2/2026 0:00 Project Principal / Vice President Project Manager Graduate Engineer Senior Engineer Designer CAD Drafter Project Rep Project Admin Contract Administrator Expenses WA2601-903A1 60% DESIGN PHASE 4 78 51 0 31 63 0 10 12 $ 0 $ 45,629 Kick-Off Meeting with City 4 4 $ 1,724 Review of Existing Reports and Record Drawings 2 4 $ 1,192 Review and incorporate tank inspection recommendations 8 6 $ 3,118 Prepare detailed structural design 6 4 $ 2,256 Prepare detailed electrical design 3 2 $ 1,128 Prepare detailed mechanical design 12 8 $ 4,512 Prepare detailed construction plans 14 11 31 63 $ 18,475 Prepare detailed specifications 5 5 4 $ 2,715 Prepare contract documents 4 5 8 $ 2,569 Prepare OPCC 5 5 3 $ 2,386 Prepare Preliminary Construction Time Estimate/Schedule 3 2 2 $ 1,282 Management, Quality Control, and Critical Coordination 4 12 $ 4,272 $ 0 WA2601-903B1 90% DESIGN PHASE 2 42 26 0 13 23 0 10 9 $ 0 $ 23,002 60% Comment Response and Resolution 4 6 3 5 3 $ 3,391 Continue detailed structural design 3 2 $ 1,128 Continue detailed electrical design 2 2 $ 862 Continue detailed mechanical design 8 4 $ 2,788 Continue detailed construction plans 6 3 10 18 $ 5,955 Continue detailed specifications 4 3 3 $ 1,979 Update contract documents 3 4 6 $ 1,946 Update OPCC 3 4 2 $ 1,612 Update Preliminary Construction Time Estimate/Schedule 3 2 1 $ 1,205 Management, Quality Control, and Critical Coordination 2 6 $ 2,136 $ 0 WA2601-903C1 FINAL 100% DESIGN PHASE 1 18 12 0 5 14 0 3 4 $ 0 $ 10,426 90% Comment Response and Resolution 1 1 1 2 $ 844 Finalize structural design 1 1 $ 431 Finalize electrical design 1 1 $ 431 Finalize mechanical design 1 1 $ 431 Finalize construction plans 2 2 4 8 $ 2,514 Finalize specifications 1 2 2 $ 876 Finalize contract documents 2 2 2 $ 966 Submit for TCEQ review 2 4 1 $ 1,141 Prepare final OPCC 2 2 $ 862 Refine Preliminary Construction Time Estimate/Schedule 2 2 $ 862 Management, Quality Control, and Critical Coordination 1 3 $ 1,068 $ 0 WA2601-904A BIDDING PHASE 0 9 10 0 0 0 0 4 10 $ 0 $ 5,752 Bidding 6 10 4 10 $ 4,954 Attend City Council Meeting for Recommendation of Award 3 $ 798 $ 0 WA2601-905A CONSTRUCTION ENGINEERING PHASE 0 26 63 0 6 7 0 18 20 $ 0 $ 23,310 Construction Administration 23 60 13 20 $ 19,819 Record Drawings - Lump Sum 3 3 6 7 5 $ 3,491 $ 0 COST PER PHASE MANHOURS/EMPLOYEE INITIALS DESCRIPTIONPHASE LOE - WA2601&WA2609 Alice EST & GST Rehab - New 5MG GST - WA2609 - REV 2026-09-02 10/19/2026 Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 WA2609-903A2 60% DESIGN PHASE 54 281 329 303 259 279 0 14 22 $ 18,900 $ 302,449 Kick-Off Meeting with City 4 4 4 $ 2,804 Review of Existing Reports and Record Drawings 4 4 $ 1,724 Establish scope of survey and geotechnical investigations 4 4 $ 1,724 Coordinate geotechnical investigations 4 2 $ 1,394 Coordinate with DD4 with regards to Drainage / Detention Requirements 4 $ 1,064 Prepare draft detention / drainage calculations 4 4 20 $ 5,724 Review existing electrical and controls, coordination with CPE as needed 4 4 $ 1,724 Confirmation that existing generator is sized for proposed loads (Subconsultant)$ 3,150 $ 3,150 Coordination with Electrical Subconsultant 4 2 $ 1,394 Prepare preliminary site layouts 20 20 40 40 60 $ 30,480 Prepare detailed structural design 35 65 $ 18,775 Prepare detailed electrical design (Subconsultant)$ 15,750 $ 15,750 Review electrical design and incorporate into project set 8 3 6 $ 3,823 Prepare detailed civil and mechanical design 90 112 120 $ 66,420 Coordinate with DD4 with regards to Drainage / Detention Requirements 5 5 $ 2,155 Prepare detailed construction plans 40 48 52 215 215 $ 89,160 Prepare detailed specifications (Includes additional pump scope)25 20 $ 9,950 Prepare contract documents (Includes additional pump scope)10 20 22 $ 9,040 Prepare OPCC 10 20 $ 5,960 Prepare and submit 60% submittal 20 20 4 4 14 $ 10,818 Prepare Preliminary Construction Time Estimate/Schedule 5 2 $ 1,660 Management, Quality Control, and Critical Coordination 50 16 $ 17,756 $ 0 WA2609-903B2 90% DESIGN PHASE 29 94 115 155 179 179 0 16 22 $ 15,750 $ 152,991 60% Comment Response and Resolution 4 4 4 $ 2,804 Continue detailed structural design 10 25 $ 6,650 Continue detailed electrical design (Subconsultant)$ 15,750 $ 15,750 Continue detailed civil and mechanical design 30 38 70 $ 28,250 Continue detailed construction plans 16 21 60 175 175 $ 68,721 Continue detailed specifications 12 10 $ 4,842 Update contract documents 5 10 22 $ 6,060 Update OPCC 5 10 $ 2,980 Prepare and submit 60% submittal 10 10 4 4 16 $ 6,662 Update Preliminary Construction Time Estimate/Schedule 4 2 $ 1,394 Management, Quality Control, and Critical Coordination 25 8 $ 8,878 $ 0 WA2609-903C2 FINAL 100% DESIGN PHASE 9 51 66 23 19 24 0 19 15 $ 12,600 $ 53,634 90% Comment Response and Resolution 4 4 4 $ 2,804 Finalize structural design 11 15 $ 4,815 Finalize electrical design (Subconsultant)$ 12,600 $ 12,600 Finalize civil and mechanical design 5 5 8 $ 3,755 Finalize construction plans 8 10 15 15 $ 7,978 Finalize specifications 10 8 $ 3,980 Finalize contract documents 3 4 4 15 $ 3,866 Submit for TCEQ review 5 8 5 $ 3,315 Prepare final OPCC 4 6 $ 2,054 Prepare and submit 100% submittal 5 8 4 4 15 $ 4,925 Refine Preliminary Construction Time Estimate/Schedule 3 2 $ 1,128 Management, Quality Control, and Critical Coordination 5 4 $ 2,414 $ 0 WA2609-904B BIDDING PHASE 6 20 40 0 0 0 0 43 55 $ 1,050 $ 25,601 Bidding 6 17 40 43 55 $ 23,753 Electrical assistance during bidding phase (Subconsultant)$ 1,050 $ 1,050 Attend City Council Meeting for Recommendation of Award 3 $ 798 $ 0 WA2609-905B CONSTRUCTION ENGINEERING PHASE 21 60 206 25 8 8 0 86 100 $ 8,400 $ 91,882 Construction Administration 20 56 200 25 81 100 $ 78,533 Electrical assistance during construction phase (Subconsultant)$ 8,400 $ 8,400 Record Drawings - Lump Sum 1 4 6 8 8 5 $ 4,949 $ 0 Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 ADDITIONAL SERVICES 7 58 130 54 25 55 0 0 0 $ 98,695 $ 159,253 WA2609-903D2 Additional design phase services (new generator)4 50 100 50 25 55 $ 21,000 $ 72,870 WA2609-905B1 Additional construction phase services (new generator)3 8 30 4 $ 8,688 WA2609-905B2 Additional electrical assistance in construction (new generator) (Subconsultant)$ 2,100 $ 2,100 WA2609-905B2 Landscape Architecture Services $ 14,770 $ 14,770 WA2609-925 Topographic Surveys (LJA Survey) - Time & Materials (Actual Cost + 5%)$ 18,900 $ 18,900 WA2609-926 Geotechnical Investigations - Time & Materials (Actual Cost + 5%)$ 41,925 $ 41,925 $ 0 TOTAL HOURS 133 737 1048 560 545 652 0 223 269 $ 893,929 RAW SALARY $100 $76 $47 $57 $42 $38 $42 $22 $40 MULTIPLIER 2.7 3.5 3.5 3.5 3.5 3.5 3.5 3.5 3.5 RATE $ 270 $ 266 $ 165 $ 200 $ 147 $ 133 $ 147 $ 77 $ 140 TOTAL ENGINEERING FEE $ 35,910 $ 196,042 $ 172,920 $ 112,000 $ 80,115 $ 86,716 $ 0 $ 17,171 $ 37,660 $ 155,395 $ 893,929 LOE - WA2601&WA2609 Alice EST & GST Rehab - New 5MG GST - WA2609 - REV 2026-09-02 10/19/2026 Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754 ID Task Mode Task Name Duration Start Finish Predecessors 1 60% Design Phase 120 days Mon 11/2/26 Mon 3/1/27 2 Kickoff Meeting / Site Visit w/ City 0 days Mon 11/2/26 Mon 11/2/26 3 Review Existing Reports and Record Drawings and Establish Scope of Survey & Geotechnical 2 days Mon 11/2/26 Tue 11/3/26 2 4 Topographic Surveys & Geotechnical 29 days Wed 11/4/26 Wed 12/2/26 3 5 Review Generator Capacity & Electrical Room & Issue Memo w/ Recommendations 16 days Thu 12/3/26 Fri 12/18/26 4 6 Preliminary Site Layouts 15 days Thu 12/3/26 Thu 12/17/26 4 7 Prepare Detailed Structural, Electrical, Mechanical, and Civil Design 49 days Fri 12/18/26 Thu 2/4/27 6 8 60% Opinion of Probable Cost 4 days Mon 2/1/27 Thu 2/4/27 9 Prepare and Submit 60% Design Package 15 days Fri 2/5/27 Fri 2/19/27 7 10 City Review Period 10 days Sat 2/20/27 Mon 3/1/27 9 11 90% Design Phase 91 days Mon 3/1/27 Mon 5/31/27 12 Attend 60% Design Review Meeting w/ City 0 days Mon 3/1/27 Mon 3/1/27 10 13 Continue Detailed Structural, Electrical, Mechanical, and Civil Design 31 days Tue 3/2/27 Thu 4/1/27 12 14 Continue Detailed Construction Plans and Specifications 35 days Fri 4/2/27 Thu 5/6/27 13 15 90% Opinion of Probable Cost 4 days Mon 5/3/27 Thu 5/6/27 16 Prepare and Submit 90% Design Package 15 days Fri 5/7/27 Fri 5/21/27 14 17 City Review Period 10 days Sat 5/22/27 Mon 5/31/27 16 18 Final 100% Design Phase 70 days Mon 5/31/27 Mon 8/9/27 19 Attend 90% Design Review Meeting w/ City 0 days Mon 5/31/27 Mon 5/31/27 17 20 Finalize Structural, Electrical, Mechanical, and Civil Design 14 days Tue 6/1/27 Mon 6/14/27 19 21 Finalize Detailed Construction Plans and Specifications 17 days Tue 6/15/27 Thu 7/1/27 20 22 Finalize Opinion of Probable Cost 4 days Mon 6/28/27 Thu 7/1/27 23 TCEQ Review 39 days Fri 7/2/27 Mon 8/9/27 21 24 Prepare and Submit 100% Design Package 12 days Fri 7/2/27 Tue 7/13/27 21 25 City Review Period 8 days Wed 7/14/27 Wed 7/21/27 24 26 Address any Final Comments and Submit Bid Package 19 days Thu 7/22/27 Mon 8/9/27 25 27 Submit Bid Package 0 days Mon 8/9/27 Mon 8/9/27 26 28 Bidding Phase and Contract Executions 54 days Mon 8/16/27 Fri 10/8/27 29 Construction Phase (480 CDs)480 days Mon 10/18/27 Thu 2/8/29 3/1 11/2 3/1 5/31 8/9 1 8 15 22 29 6 13 20 27 3 10 17 24 31 7 14 21 28 7 14 21 28 4 11 18 25 2 9 16 23 30 6 13 20 27 4 11 18 25 1 8 15 22 29 5 12 19 26 3 10 17 24 31 November December January February March April May June July August September October November Task Split Milestone Summary Project Summary Inactive Task Inactive Milestone Inactive Summary Manual Task Duration-only Manual Summary Rollup Manual Summary Start-only Finish-only External Tasks External Milestone Deadline Progress Manual Progress City of Pearland WA2601 - Alice Elevated and Ground Storage Tank Rehabilitation and WA2609 - Alice Water Treatment Plant New 5-Million-Gallon Ground Storage Tank LJA, Inc. Project: WA2609 Date: Fri 9/4/26 Docusign Envelope ID: C28D5CF5-C29B-8338-815B-7578F282F754