R2023-223 2023-09-25RESOLUTION NO. R2023-223 A Resolution of the City Council of the City of Pearland, Texas, awarding a contract associated with Natatorium Air Handler Replacement Project to Texas Air Systems, in the amount of $651,970.00. BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF PEARLAND, TEXAS: Section 1. That competitive bids were obtained for Natatorium Air Handler Replacement Project. Section 2. That the City Council hereby awards a contract to Texas Air Systems, in the amount of $651,970.00. Section 3. The City Manager or his designee is hereby authorized to execute a construction services contract for the Natatorium Air Handler Replacement Project. PASSED, APPROVED and ADOPTED this the 25th day of September, A.D., 2023. ________________________________ J.KEVIN COLE MAYOR ATTEST: ________________________________ FRANCES AGUILAR, TRMC, MMC CITY SECRETARY APPROVED AS TO FORM: ________________________________ DARRIN M. COKER CITY ATTORNEY DocuSign Envelope ID: 9B4B004F-F6BC-43DC-A994-EF092B76B63B DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- City of Pearland 3519 Liberty Drive Pearland, TX 77581 SUPPLY CONTRACT NO. C0823-23 For (2) Terntrol Custom Indoor Air Handling Units for the Natatorium Air Handling Replacement Project THIS Contract ("Contract") is entered into by and between the City of Pearland, a Texas home- rule municipal corporation ("City") and Texas Air Systems LLC ("Contractor"), and consisting of the following parts: I. Summary of Contract Terms 11. Signatures 111. Standard Contractual Provisions IV. Special Terms and Conditions V. Additional Contract Attachments I. Summary of Contract Terms. Contractor: Texas Air Systems LLC 9021 South Houston Parkway West, Suite 100 Missouri City, Texas 77489 Description of Supplies: (2) Temtrol Custom Indoor Air Handling Units per the plans and specs 23 73 13.19 Custom Hydronic Pool Dehumidification Air Handling units for the Natatorium Air Handling Unit Replacement. Contract Amount: $651,970.00 Effective Date: September 12, 2023 End Date: March 30, 2025 Renewals: 0 Resolution No/Bid No: R2023- , TIPS Contract#22010601 11. Signatures 7 OPePiEARLAND CONTRACTOR pf"a 9/28/2023 1 4:01 PM CD D8FA1B5BD467... PWA*ft YQ ff i c e r Date TitI6, ,,' Accou'lit Executive 9/28/2023 4:49 Mll b),,September 13, 2023 *Signed by: Date Superintendent/Manager Director Deputy/Assistant City Manager City Manager *City Contract Signature Authority: Superintendent/Manager—up to $10,000 Director-$10,001 -$30,000 City Manager/Deputy/Assistant City Manager-$30,001 + City Council Resolution over$50,000 Supply Contract Standard Form Page 1 of 6 Approved as to Legal Form 6.28.2021 --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- III. Standard Contract Provisions WHEREAS, Contractor has bid to provide supplies ("Supplies") in response to TIPS Contract # 22010601 ("Solicitation"), which Solicitation includes the required scope of work and all specifications and which Solicitation and the Contractor's bid or proposal response, as applicable, are incorporated by reference in this Contract as Exhibits 1 and 2, respectively, as if each were fully set out here in its entirety. NOW, THEREFORE, City and Contractor agree as follows: 1. Scope. Contractor will provide Supplies in accordance with the attached Scope of Work, as detailed in Attachment A, the content of which is incorporated by reference into this Contract as if fully set out here in its entirety, and in accordance with Exhibit 2. 2. Term. This Contract end date is March 30,2025, with performance commencing upon the effective date or the date of issuance of the notice to proceed issued by the Contract Administrator or the Purchasing Division, or upon the performance date listed in the notice to proceed, whichever is later. The parties may mutually extend the Term of this Contract for up to (0) additional one-year periods ("Option Period(s)"), provided, the parties do so by written amendment prior to the expiration of the original term or the then-current Option Period. The City's extension authorization must be executed by the City Manager or designee. 3. Compensation and Payment. This Contract is for an amount not to exceed $651,970.00, subject to approved extensions and changes. Payment will be made for Supplies completed and accepted by the City within thirty (30) days of acceptance, subject to receipt of an acceptable invoice. Contractor shall invoice no more frequently than once per month. All pricing must be in accordance with the attached Bid/Pricing Schedule, as shown in Attachment B, the content of which is incorporated, in its entirety, by reference into this Contract. Any amount not expended during the initial term or any option period may, at the City's discretion, be allocated for use in the next option period. Invoices will be emailed to the following email address with a copy provided to the Contract Administrator: City of Pearland Attn: Accounts Payable Email: accounts ayable pearlandtx.gov 4. Contract Administrator. The Contract Administrator designated by the City is responsible for approval of all phases of performance and operations under this Contract, including deductions for non-performance and authorizations for payment. The City's Contract Administrator for this Contract is as follows: Name: Francesca Beltran Department: Engineering and Public Works Phone: 281.652.1946 Email: TheItran@pearlandtx.gov 5. Insurance; Bonds. (A) Before performance can begin under this Contract, the Contractor must deliver a Supply Contract Standard Form Page 2 of 6 Approved as to Legal Form 6.28.2021 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- Certificate of Insurance ("COI"), as proof of the required insurance coverages, to the Contract Administrator. Additionally, the COI must state that the City shall be provided no less than thirty (30) days' advance written notice of cancellation, material change in coverage, or intent not to renew any of the policies. The City must be named as an additional insured. The City Attorney must be given copies of all insurance policies within ten (10) days of the City Manager or his designee's written request. Insurance requirements are as stated in Attachment C, the entirety of which is incorporated by reference into this Contract. (B) I Contractor shall provide any required payment bond, performance bond, or both, prior to commencement of performance under this Agreement. The terms, conditions, and amounts of the bonds and appropriate surety information shall be included in the RFB/RFP or as may be added to Attachment C, and such content, the entirety of which, shall be incorporated into this Contract y. 6. Purchase Release Order. For multiple-release purchases of Supplies to be provided by the Contractor over a period of time, the City will exercise its right to specify time, place and quantity of Supplies to be delivered in the following manner: the authorized City department or division shall send to Contractor a purchase release order signed by an authorized agent of the department or division. The purchase release order shall refer to this Contract, and Supplies shall not be rendered until the Contractor receives the signed purchase release order. 7. Inspection and Acceptance. City may inspect all Supplies before acceptance. Any Supplies or products that are provided but not accepted by the City must be corrected or re-worked immediately at no charge to the City. If immediate correction or re-working at no charge cannot be made by the Contractor, replacement Supplies may be procured by the City on the open market and any costs incurred, including additional costs over the item's bid/proposal price, shall be paid by the Contractor within thirty (30) days of receipt of City's invoice. 8. Warranty. (A) The Contractor warrants that all products supplied under this Contract are new, quality items that are free from defects, fit for their intended purpose, and of good material and workmanship. The Contractor warrants that it has clear title to the products and that the products are free of liens or encumbrances. (B) In addition, the products purchased under this Contract shall be warranted by the Contractor or, if indicated in Attachment D by the manufacturer, for the period stated therein. Attachment D, the entirety of which, is incorporated into this Contract. 9. Quality/Quantity Adjustments. Any quantities indicated on the Bid/Pricing Schedule are estimates only and do not obligate the City to order or accept more than the City's actual requirements nor do the estimates restrict the City from ordering less than its actual needs during the term of the Contract including any Option Period. Substitutions and deviations from the City's product requirements or specifications are prohibited without the prior written approval of the Contract Administrator. 10. Non-Appropriation. The continuation of this Contract after the close of any fiscal year of the City, which fiscal year ends on September 30th annually, is subject to appropriations and budget approval specifically covering this Contract as an expenditure in said budget, and it is within the sole discretion of the City's City Council to determine whether or not to fund this Contract. The City does not represent that this budget item will be adopted, as said determination is within the City Council's sole discretion when adopting each budget. Supply Contract Standard Form Page 3 of 6 Approved as to Legal Form 6.28.2021 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 11. Independent Contractor. Contractor shall perform all work required by this Contract as an independent contractor and will furnish such Supplies in its own manner and method, and under no circumstances or conditions will any agent, servant or employee of the Contractor be considered an employee of the City. 12. Amendments. This Contract may be amended or modified only in writing and executed by authorized representatives of both parties. 13. Waiver. No waiver by either party of any breach of any term or condition of this Contract waives any subsequent breach of the same. 14. Taxes. The Contractor covenants to pay payroll taxes, Medicare taxes, FICA taxes, unemployment taxes and all other applicable taxes. Upon request, the City Manager shall be provided proof of payment of these taxes within 15 days of such request. 15. Notice. Any notice required under this Contract must be given by hand delivery, or certified mail, postage prepaid, and is deemed received on the day hand-delivered or on the third day after postmark if sent by certified mail. Notice must be sent as follows: IF TO CITY: City of Pearland Attn: Jennifer Lee Title: Senior Project Manager Address: 2016 Old Alvin Road, Pearland, TX 77581 Phone: 281.652.1760 IF TO CONTRACTOR: Texas Air Systems, LLC Attn: J. Chase Williamson Title: Account Executive Address: 9021 South Sam Houston Parkway West, Suite 100, Missouri City, TX 77489 Phone: 832.342.7000 16. Liability and Indemnity. ANY PROVISION OF ANY ATTACHED CONTRACT DOCUMENT THAT LIMITS THE CONTRACTOR'S LIABILITY TO THE CITY OR RELEASES THE CONTRACTOR FROM LIABILITY TO THE CITY FOR ACTUAL OR COMPENSATORY DAMAGES, LOSS, OR COSTS ARISING FROM THE PERFORMANCE OF THIS CONTRACT OR THAT PROVIDES FOR CONTRACTUAL INDEMNITY BY ONE PARTY TO THE OTHER PARTY TO THIS CONTRACT IS NOT APPLICABLE OR EFFECTIVE UNDER THIS CONTRACT. EXCEPT WHERE AN ADDITIONAL CONTRACT DOCUMENT PROVIDED BY THE CITY PROVIDES OTHERWISE, EACH PARTY TO THIS CONTRACT IS RESPONSIBLE FOR DEFENDING AGAINST AND LIABLE FOR PAYING ANY CLAIM, SUIT, OR JUDGMENT FOR DAMAGES, LOSS, OR COSTS ARISING FROM THAT PARTY'S NEGLIGENT ACTS OR OMISSIONS IN THE PERFORMANCE OF THIS CONTRACT IN ACCORDANCE WITH APPLICABLE LAW. THIS PROVISION DOES NOT AFFECT THE RIGHT OF EITHER PARTY TO THIS CONTRACT WHO IS SUED BY A THIRD PARTY FOR ACTS OR OMISSIONS ARISING FROM THIS CONTRACT TO BRING IN THE OTHER PARTY TO THIS CONTRACT AS A THIRD- PARTY DEFENDANT AS ALLOWED BYLAW. Supply Contract Standard Form Page 4 of 6 Approved as to Legal Form 6.28.2021 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- 17. Dispute Resolution Procedures. The Contractor and City desire an expeditious means to resolve any disputes that may arise between them regarding this Contract. If either party disputes any matter relating to this Contract, the parties agree to try in good faith, before bringing any legal action, to settle the dispute by submitting the matter to mediation before a third party who will be selected by agreement of the parties. The parties will each pay one-half of the mediator's fees. 18. Attorney's Fees. Should either party to this Contract bring suit against the other party for breach of contract or for any other cause relating to this Contract, neither party will seek or be entitled to an award of attorney's fees or other costs relating to the suit. 19. Termination. (A) City Termination for Convenience. Under this paragraph, the City may terminate this Contract during its term at any time for the City's own convenience where the Contractor is not in default by giving written notice to Contractor. If the City terminates this Contract under this paragraph, the City will pay the Contractor for all Supplies provided in accordance with this Contract to the date of termination. (B) Termination for Default. Either party to this Contract may terminate this Contract as provided in this paragraph if the other party fails to comply with its terms. The party alleging the default shall provide the other party notice of the default in writing citing the terms of the Contract that have been breached and what action the defaulting party must take to cure the default. If the party in default fails to cure the default as specified in the notice, the party giving the notice of default may terminate this Contract by written notice to the other party, specifying the date of termination. Termination of this Contract pursuant to this paragraph does not affect the right of either party to seek remedies for breach of the Contract as allowed by law, including any damages or costs suffered by either party. 20. Owner's Manual and Preventative Maintenance. Contractor agrees to provide a copy of the owner's manual and/or preventative maintenance guidelines or instructions if available for any equipment purchased by the City pursuant to this Contract. Contractor must provide such documentation upon delivery of such equipment and prior to receipt of the final payment by the City. 21. Limitation of Liability. The City's maximum liability under this Contract is limited to the total amount of compensation listed in this Contract. In no event shall the City be liable for incidental, consequential or special damages. 22. Assignment. No assignment of this Contract by the Contractor, or of any right or interest contained herein, is effective unless the City Manager first gives written consent to such assignment. The performance of this Contract by the Contractor is of the essence of this Contract, and the City Manager's right to withhold consent to such assignment is within the sole discretion of the City Manager on any ground whatsoever. 23. Severability. Each provision of this Contract is considered to be severable and, if, for any reason, any provision or part of this Contract is determined to be invalid and contrary to applicable law, such invalidity shall not impair the operation of nor affect those portions of this Contract that are valid, but this Contract shall be construed and enforced in all respects as if the invalid or unenforceable provision or part had been omitted. 24. Order of Precedence. In the event of any conflicts or inconsistencies between this Contract, its attachments, and exhibits, such conflicts and inconsistencies will be resolved by reference Supply Contract Standard Form Page 5 of 6 Approved as to Legal Form 6.28.2021 DocuSign Envelope ID:4DDFB63B-7AD0-41 131-B32F-0EBCA9573CB9 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- to the documents in the following order of priority: A. this Contract (excluding attachments and exhibits); B. its attachments; C. the bid solicitation document including any addenda (Exhibit 1); then, D. the Contractor's bid response (Exhibit 2). 25. Certificate of Interested Parties. Contractor agrees to comply with Texas Government Code Section 2252.908, as it may be amended, and to complete Form 1295 "Certificate of Interested Parties" as part of this Contract if required by said statute for items approved by City Council. 26. Governing Law. Contractor agrees to comply with all federal, Texas, and City laws in the performance of this Contract. The applicable law for any legal disputes arising out of this Contract is the law of the State of Texas, and such form and venue for such disputes is the appropriate district, county, or justice court in and for Brazoria County, Texas. 27. H.B. 89. In accordance with Chapter 2270 of the Texas Government Code, the signatory executing this contract on behalf of company verifies that the company does not boycott Israel and will not boycott Israel during the term of this contract. This clause is subject to companies with ten or more full time employees and the contract value is $100,000 or more that is to be paid wholly or partially with public funds of the governmental entity. 28. Public Information Act Requirements.This paragraph applies only to agreements that have a stated expenditure of at least $1,000,000 or that result in the expenditure of at least $1,000,000 by the City. The requirements of Subchapter J, Chapter 552, Government Code, regarding certain entities requirement to provide contracting information to governmental bodies in connection with a public information request, may apply to this contract and the Contractor agrees that the contract can be terminated if the Contractor knowingly or intentionally fails to comply with a requirement of that subchapter. 29. Entire Contract. This Contract constitutes the entire agreement between the parties concerning the subject matter of this Contract and supersedes all prior negotiations, arrangements, agreements, and understandings, either oral or written, between the parties. IV. Special Terms and Conditions. None V. Additional Contract Documents Attached and Incorporated by Reference: Attachment A: Scope of Work Attachment B: Bid/Pricing Schedule Attachment C: Insurance and Bond Requirements Attachment D: Warranty Requirements Incorporated by Reference Only: Exhibit 1: TIPS Contract#22010601 Exhibit 2: Contractor's Bid/Proposal Response Supply Contract Standard Form Page 6 of 6 Approved as to Legal Form 6.28.2021 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ATTACHMENT A — SCOPE OF WORK Vendor shall provide (2) temtrol custom indoor air handling units per the plans and specification 23 73 13.1 Custom Hydronic Pool Dehumidification Air Handling Units for the Natatorium Air Handling Replacement Project. DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ATTACHMENT B - BID/PRICING SCHEDULE TIPS Cominrao Ncr. 22010601. EQUIPAIENT S F ASIS OF DE`1;4� iuuuui° ffliaw i� i�� .................................. ui Oil 111111 SIC�����1111 Ten-itrol Oi�tgam Indgaoi:A�r Ha-nclli L7 NAHU-0 I &02 7..............2!1!..........................................1111 1 R 'TENITROL CUSTOM 11%MOOR.AIR FUINMLINGUNITS (2,)IT!F Sefies,HoLzantal Draw-nui:i,Cmstom Ind&x AiL-Handling U,mts De-,igaaed for 46Ora/,3P.h,,,1'6,OHZ Fowef: • Configiva6on per 11-604 • peffarni'mce Ix-f 11--501 • Constrictian 13,e,,c 237313.1.9 • Rtpid Kmock-D-own Comtructi-m:Post-arid-Parx-1 Constowtioil Allows for Easv Dis,(Re-Amembly. T-7mv,Ship in Itildple ShL-dc—Wiapped Secbram, KTI,idi XLrLmml Liss fled Fasteners ind No Gasket/C-azillmig.All Reqiired Gasket;and Caulk It brefLil Sh ps Loose for.Field Lastillatrati aftei:As-embiv.. Field Installed I aeiim 0 2"MERV 11 Filters(3 Coail3lete Sets)i Senaces and Warumfies: • Fre*ht to jobsAe/Stouage Facility • Field Cabinet Lea)mge mind Deflection Testitig • One Year Puts and Lt:bor Waalluir" Not Lficluded:� • Extended Wmaities,VaLable Freqiencv DL-res,DDC Contfohl,Din per Acnmtoi:s,Contiol Valves,cu Pzpaig Faclmgesl CrAtistoactioii Filtev-, Labor/Servxes-,Si-noke Detectors,Smoke Ddm-specs,Free Stats-,aiad/orkny. Item Not Sjaecificall-, I ist�ed Above. --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- DocuSign Envelope ID:4DDFB63B-7ADO-41 B1-B32F-OEBCA9573CB9 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ATTACHMENT C - INSURANCE REQUIREMENTS Purchasing Department City of Pearland 281.652.1775 �144A 3519 Liberty Drive ebids(a-)PearIandtL.gov Pearland,TX 77581 Contractor Insurance Requirements &Agreement Contractors performing work on City property or public right-of-way for the City of Pearland shall provide the City a certificate of insurance or a copy of their insurance policy(s) evidencing the coverages and coverage provisions identified herein. Contractors shall provide the City evidence that all subcontractors performing work on the project have the same types and amounts of coverages as required herein or that the subcontractors are included under the contractor's policy. All insurance companies and coverages must be authorized by the Texas Department of Insurance to transact business in the State of Texas and must be acceptable to the City of Pearland. Listed below are the types and amounts of insurances required.The City reserves the right to amend or require additional types and amounts of coverages or provisions depending on the nature of the work. TYPE OF INSURANCE AMOUNT OF INSURANCE PROVISIONS 1. Workers'Compensation Statutory Limits For WC, CGL,and BAL,the City is Employers'Liability (WC) $1,000,000 per occurrence to be provided a WAIVER OF SUBROGATION. 2. Commercial General(Public) Personal Injury-$1,000,000 per CGL and BAL,City to be listed as Liability(CGL)to include coverage person; Property Damage- additional insured and provided 30- fo r: $1,000,000 per occurrence; day notice of cancellation or material a) Premises/Operations General Aggregate-$2,000,000 change in coverage. b) Products/Completed Operations WC, CGL and BAL, City shall be c) Independent Contractors provided 30-day notice of d) Personal Injury cancellation or material change in e) Contractual Liability coverage. 3. Business Auto Liability(BAL)to Combined Single Limit- include coverage for: $1,000,000 CGL will include a non-contributory a) Owned/Leased vehicles addendum. b) Non-owned vehicles c) Hired vehicles Ifthe contract involves a professional service,the contractorwill also be required to provide the City with professional liability insurance in an amount of at least$1,000,000. Certificate of Insurance forms may be emailed to: Purchasing Department at ebidsppeariandtx.gov.Questions regarding required insurance should be directed to City of Pearland Purchasing Department,at ebidsQpearlandtx.gov. This form must be signed and returned with your bid/quotation.You are stating that you do have the required insurance and if selected to perform work for the City,will provide a certificate of insurance,and a copy of insurance policy with the above requirements to the City.A purchase order will not be issued without evidence of required insurance. Agreement I agree to provide the above described insurance coverages within 10 working days if selected to perform work for the City of Pearland. I also agree to provide the City evidence of insurance coverage on any and all subcontractors performing work on the project. Project/Bid# Company: Signature and PrintedName: --------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 -------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- ATTACHMENT D —WARRANTY Items or services shall conform to the proposed specifications and all warranties as stated in the Uniform Commercial Code and be free from all defects in material, workmanship and title. DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 CITY OF PFARLAIVD STANDARD FORM OF AGRFEM. ENT APPEIti DIX B House Bill 89 Verification C , Ammrd ..... ............. (Person name), the undersigned representative (hereafter referred to as "Representative") of axis s �........ (company or business name, hereafter referred to as "Business Entity"), being an adult over the age of eighteen (18)years of age, after being duly sworn by the undersigned notary, do hereby depose and affirm the following: 1 . That Representative is authorized to execute this verification on behalf of Business E ntity; 2. That Business Entity does not boycott Israel and will not boycott Israel during the term of any contract that will be entered into between Business Entity and the City of Peariand; and 3. That Representative understands that the term "boycott Israel" is defined by Texas Government Code Section 2270.001 to mean refusing to deal with, terminating business activities with, or otherwise taking any action that is intended to penalize, inflict economic harm on, or limit commercial relations specifically with Israel, or with a person or entity doing business in Israel or in an Israeli-controlled territory, but does not include an action made for ordinary business purposes. SIGNATU E F RE RESENTATIVE SUBSCRIBED AND SWORN TO BEFORE ME, the undersigned authority, on this day of �v �s► 20 23 �4 cea kw>F 4 S y ill ���O 111,� iil Notary P'u re� Public'' DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 CERTIFICATE OF INTERESTED PARTIES FORM 1295 1 of 1 Complete Nos.1-4 and 6 if[here are interested parties. OFFICE USE ONLY Complete Nos.1,2,3,5,and 6 if there are no inrerested parties. CERTIFICATION OF FILING 1 Name of business entity filing form,and the city,state and country of the business entity's place Certificate Number: of business. 2023-1062378 Texas AirSystems Irving,TX United States Date Filed: 2 Name of governmental entity or state agency that is a party to the contract for which the form is 08/21/2023 being filed. City of Pearland Date Acknowledged: 3 Provide the identification number used by the governmental entity or state agency to track or identify the contract,and provide a description of the services,goods,or other property to be provided under the contract. 22010601 HVAC Equipment Nature of interest 4 Name of Interested Party City,State,Country[place of business] (cheek applicable) Controlling Intermediary 5 Check only if there is NO Interested Party. x 5 UNSWORN DECLARATION ,/ Afy r ar re s x �{ �� , and my date❑f birth is Fawn �y�yd, My address is A f 770'IL _11AS (street) (oly) %state) (zip code) (muntry) I declare under penalty of perjury that the foregdng is true and correct. q Executed in Awat County, Stag.of on the e2 l day of WW 2043= (mcnth) (year) S+gnalur of ihori,ed a nl of contracting business entity [Derlarant) Forms provided by Texas Ethics Commission www.elhics.state.tx.us Version V3.5.1.39e&620 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 TEXAS 41U QUUTATIGNIAll"'i'SYSTEMS Date: August 10,2023 Project: City of Pearland Natatorium AHU Replacement at Recreation Center and Natatorium Engineer: LEAF Engineers Plans Dated: Early Equipment Package Plans and Specs dated August 3,2023 Addendum: 1 TIPS Con1ro.c1 To. 22011.016011. EQUIPMENT SUMMARY 1:1S1S 1_l " 1 I^;S1C �Illlli �� 6 I�IWW�� p pl u k IIIIIIIIIIII w^II` u4Il�o°uw llu ajol� lull 16lllllll�lll�llllilllll�Illlllllllllllmlllllllllllllllll�llllll IIIIII IIIIIII lllllllll � ������������� I�IIIIII' I�Illllullllllllllllllllllllllll�lllllll�IIIIIIIII�I ��� II Temtrol Custom Indoor Air Handlin Units 2 NAHU-01 &02 $651,970.00 .................................................................................................................................................................g........................................................,..,,..,......�.................................................................................................................................................................................................................................................................................................. TEMTROL CUSTOM INDOOR AIR HANDLING UNITS Qty.(2)ITF Series,Horizontal Draw-Thru,Custom Indoor Air-Handling Units Designed for 460V/3Ph/60HZ Power: • Configuration per M-604 • Performance per M-501 • Constmction per 237313.19 • Rapid Knock-Down Construction:Post-and-Panel Construction Allows for Easy Dis/Re-Assembly. Units Ship in Multiple Shrink-Wrapped Sections with Minimal Installed Fasteners and No Gasket/Caulking.All Required Gasket and Caulk Material Ships Loose for Field Installation after Assembly. Field Installed Items: • 2"MERV 11 Filters(3 Complete Sets) Services and Warranties: • Freight to Jobsite/Storage Facility • Field Cabinet Leakage and Deflection Testing • One Year Parts and Labor"Varranty Not Included: • Extended Warranties;Variable Frequency Drives;DDC Controls;Damper Actuators;Control Valves or Piping Packages;Constmction Filters; TAB/Commissioning/Maintenance Labor/Services;Smoke Detectors;Smoke Dampers;Fire Stats;and/or Any Item Not Specifically Listed Above. Thank you for the opportunity to provide equipment on this project! �m Chase W llk ausinsonn, P.1", I11,1,L,1y Al' Account, V+.xccuuuivc 9021 [South "Som ll lla.:u:u,ton llod'woy Wu ssu, ``'Suuitc 1100 � 1Vllkssounr�i 9.uuy,"I''X /7zl8l) Office:8313,117000 � Direct: 832.3zl1/00'fl Tlus quotation is subject to change without notice and void Atef 15 days. -Add to the prices quoted any sales tax payable on the transaction under any effective Federal of State statute. -F.O.B.Factofy,FFA,pef mutually agreed schedule.No matefial to be fetufned without written authofization. -Payment tefms:Net 30 Days,Upon Receipt of Satisfactoty Credit Infofmation. -Texas AifSystems egtfipment will be supplied based upon appfoved submittal data. -Retainage is not allowed.Texas AifS,vstems is a matefial supplief and will be supplying the entire pufchase ofdef value upon delivety of equipment. -Payment to Texas AifS,vstems cannot be conditioned on feceipt of payment from the ownef by a contfactof,construction managef,of customef. -Texas AifS,vstems standud waffanty,pafts only,is fof 12 months from staft-up date,not to exceed 18 months from ship date. -Texas AifS,vstems is fesponsible and accountable only fof the acts and ofnissions of Texas AifS,vstems. -Instuance ceftiffcates and bonds can/will be pfovided upon fequest. 19(01 8. aal ileu�uAon 11'14% m W,µel lc� 1000, hdb�u�arr�City i"N 7748t,) tw ,�4 83134 "l`I°8H) w 4au . ?91d 1' 9f y8S1 s ro.a. . .a. <...... ....... --" -- ,< ... _ Page 1 of 1 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 "S SLJ &�'vll................................. X�l............... 1`111 SYSTEMS TEMTROL INDOOR CUSTOM AIR-HANDLING UNITS FOR CITY OF PEARLAND NATATORIUM AIR HANDLING UNIT REPLACEMENT III IiiU MEP Engineer: LEAF Engineers Date: August 9, 2023 Revision: 0 —For Review&Approval Submitted By: J. Chase Williamson,P.E.,LEED AP Equipment Manufacturer: Temtrol (Basis of Design) Equipment Type: Custom Hydronic Pool Dehumidification Units Unit Tags: NAHU-01 & 02 10 12 V ci,�ks "k,',',,xasAJ 9021 Swi-i llollsixm J1k%N'y_'NV,SFE, 100,Nfissoud('Jty I X.7"189 w klahr 832342_7001) a I m 2,8,',1 11 8,C)"28,8 1 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 " 1`111 SYSTEMS EQUIPMENT SCOPE TEMTROL INDOOR CUSTOM AIR HANDLING UNITS Qty. (2) ITF Series,Horizontal Draw-Thru,Chilled Water Cooling,Hot Water Heating,Custom Indoor Air-Handling Units Designed for 460V/3Ph/60HZ Power: • Configuration per M-604 • Performance per M-501 • Construction per 237313.19 • Rapid Knock-Down Construction: Post-and-Panel Construction Allows for Easy Dis/Re-Assembly. Units Ship in Multiple Shrink-Wrapped Sections with Minimal Installed Fasteners and No Gasket/Caulking.All Required Gasket and Caulk Material Ships Loose for Field Installation after Assembly. Field Installed Items: • 2"MERV 11 Filters (3 Complete Sets) Services and Warranties: • Freight to Jobsite/Storage Facility • Field Cabinet Leakage and Deflection Testing • One Year Parts and Labor Warranty Not Included: • Extended Warranties;Variable Frequency Drives;DDC Controls;Damper Actuators;Control Valves or Piping Packages;Construction Filters;TAB/Commissioning/Maintenance Labor/Services;Smoke Detectors;Smoke Dampers;Fire Stats;and/or Any Item Not Specifically Listed Above. 1.4,, w,.a.l!i.AJ rSi,,rsll,w„1111,y"i,ic,in, """w 90211 1tis111 I1011'sumy:i 1'N wwh 'SO I:. ll00 'bisso'llri 'I X 77P189 w lw'lahi 84.E �4� - ,f;01) a In ,81 '1q`lf) 8,81----- DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas SECTION 23 73 13.19- CUSTOM HYDRONIC POOL DEHUMIDIFICATION AIR HANDLING UNITS COMPLY ��nli sIl ec. :�lcati uq ect, :i a I� Il i f n e i1 �.q,u�ill�men�t II Drocu�ui��.men�t 11Dac[age nd u�uiliuqe the manufacturers and mode qui,Nbers f the eq,Oill�men�i k: Ibe IlDu�ui'chas��d 1��efb en�ce the drawn :iu�q nd �.q,u�iprreni schedUes for actual ��.q,u�ill�rren�i ia���ndNed s Il�e�igq Ili il f the e i1 II Drocu�ui��.rren t 11Dac[k ge All other refbi'��.nc liu� ill�nl II I".�;i i�; kai u� k: liu ill kai n and Il h du�uct dill be Ili ii f the base Ik:�d coigstr�uctk n� contract a u�ued s�`.Iparat .y All igstall to n� items iillniuq kahnis sII ec. :flcatai uq shan 11 Ibe the i�� ll� n��ill�ilik. � theIiu��i IVliu�q contractor nd work scope ia��°nd,Ned i Ibe Ili ii f k.Ihe (base Il :d coigsti�uctk n contract C mpete eq,Opmen t sUbmiitta6s are due at the clime of sUbm�:s li uq for the eai1y eq,Opment Dac[k ge Any sUbmI :tted iilln up a sUbmI :il 4 IlDac[k ge will not be accepted All sUbmI :ttals shal6 c uqp l',uq :ne by liu e sII ec, : cat, ' uq c r pql :':aigce as we1 s a 'ne by line eq,Opmen t schedUe c irr pql : igce to I',ug6cate Droposer lip c rrpl y� :uqq i:thn eq,Opmeni Ili tee Hin kllnis spec. :flcatai iq Any a eve:, ta: n s from the Il ec. :disci oiq shouVd be nligllnlighted and idend,Cied and reason for devi ta: n Any Hgco rnp ete sUIbmliit l dill not be accepted �.q,Oprreigt span l Ibe sIlnipped to the IlDroi ct i llb§ite or to a e§,ginated storage f cilik. ; coordliigate exact deivery address with II he Cii f 14���I . i1aig1 r the i�a1ed iugsk. I iqg cant acto'Il�i�i i�k: sIlnipment. PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. 1.2 SUMMARY A. Section includes modular factory fabricated air-handling units and accessories. B. Related Sections: 1. Section 23 05 00 -Common Work Results for HVAC. 2. Section 23 05 48 -Vibration and Seismic Controls for HVAC Piping and Equipment: Product requirements for vibration isolators for placement by this section. 3. Section 23 07 16 - HVAC Equipment Insulation: Product requirements for insulation for placement by this section. 4. Section 23 33 00 - Air Duct Accessories: Product requirements for flexible duct connections for placement by this section. 5. Section 23 05 13 - Common Motor Requirements for HVAC Equipment: Product requirements for electric motors for placement by this section. 6. Section 23 05 14 -Variable Frequency Controllers. 1.3 REFERENCES A. Air-Conditioning and Refrigeration Institute: 1. ARI 550/590-Water Chilling Packages Using the Vapor Compression Cycle. B. American Society of Heating, Refrigerating and Air-Conditioning Engineers: CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 237313.19- 1 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas COMPLY 1. ASHRAE 15 -Safety Code for Mechanical Refrigeration. 2. ASHRAE 90.1 - Energy Efficient Design of New Buildings Except Low-Rise Residential Buildings. C. American Society of Mechanical Engineers: 1. ASME Section VIII -Boiler and Pressure Vessel Code- Pressure Vessels. D. Underwriters Laboratories Inc.: 1. UL 1995- Heating and Cooling Equipment. 1.4 EXECUTIVE SUMMARY A. Unit manufacturer's representative is responsible for providing replacement chilled water / hot water pool dehumidification/air conditioning unit as a direct replacement for the existing DX Dectron unit in place. Unit MUST fit exact dimensions as laid out on plans including exact duct openings, elevations, and locations to allow for direct replacement of existing unit without any duct transitions or turns. Coatings, build requirements, and schedule requirements noted in sections 2.2, 2.3, and 2.4 must be adhered to strictly with no deviations. 1.6 ACTION SUBMITTALS A. Provide line-by-line specification review annotated to certify compliance or deviation. B. Provide line-by-line schedule notes review annotated to certify compliance or deviation. C. Provide Footprint Square Footage Discrepancy Chart in spreadsheet form. Clearly show the differences in height, length, and width between the submitted units and designed units per plans for each AHU with corresponding tag. D. Shop Drawings: Indicate assembly, unit dimensions, weight loading, required clearances, construction details, field connection details, and electrical characteristics and connection requirements. E. Product Data, Submit the following: 1. Published Literature: Indicate capacities, ratings, gages and finishes of materials, and electrical characteristics and connection requirements. 2. Filters: Data for filter media, filter performance data, filter assembly, and filter frames. 3. Fans: Performance and fan curves with specified operating point plotted, power, RPM. 4. Sound Power Level Data: Fan outlet and casing radiation at rated capacity per ARI 260. 5. Electrical Requirements: Power supply wiring including wiring diagrams for interlock and control wiring. Indicate factory installed and field installed wiring. CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 23 73 13.19-2 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas COMPLY F. Manufacturer's Installation Instructions: Submit. G. Manufacturer's Certificate: Certify products meet or exceed specified requirements. 1.6 INFORMATIONAL SUBMITTALS A. Coordination Drawings: Floor plans, drawn to scale, on which the following items are shown and coordinated with each other, using input from installers of the items involved: 1. Structural supports. 2. Piping roughing-in requirements. 3. Wiring roughing-in requirements, including spaces reserved for electrical equipment. 4. Access requirements, including working clearances for mechanical controls and electrical equipment, and tube pull and service clearances. B. Certificates: For certification required in "Quality Assurance"Article. C. Source quality-control reports. D. Startup service reports. E. Warranty: Sample of special warranty. 1.7 CLOSEOUT SUBMITTALS A. Operation and Maintenance Data: Submit instructions for lubrication, filter replacement, motor and drive replacement, spare parts lists, and wiring diagrams. 1.8 QUALITY ASSURANCE A. Electrical Components, Devices, and Accessories: Listed and labeled as defined in NFPA 70, by a qualified testing agency, and marked for intended location and application. B. NFPA Compliance: Comply with NFPA 90A for design, fabrication, and installation of air- handling units and components. C. ARI Certification: Air-handling units and their components shall be factory tested according to ARI 430, "Central-Station Air-Handling Units," and shall be listed and labeled by ARI. D. ASHRAE Compliance: Applicable requirements in ASHRAE 62.1, Section 5-"Systems and Equipment" and Section 7-"Construction and Startup." E. ASHRAE/IESNA 90.1 Compliance: Applicable requirements in ASHRAE/IESNA 90.1, Section 6-"Heating, Ventilating, and Air-Conditioning." F. Comply with NFPA 70. CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 23 73 13.19-3 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas COMPLY 1.9 QUALIFICATIONS A. Installer: Company specializing in performing Work of this section with minimum three (3) years experience. 1.10 DELIVERY, STORAGE,AND HANDLING A. Equipment shall be factory wrapped by the manufacturer prior to shipment to prevent damage due to weather and road debris during transportation and thereafter while in storage awaiting installation. Protection of the complete unit from rusting and water migration must be handled as best suits the circumstances. Store in a place protected from construction traffic and weather. B. All equipment shall remain in manufacturer's protective shipping wrap during construction. Openings must remain protected and covered during construction. If protective wrap has been damaged,the contractor shall provide additional protective wrap as directed by engineer. C. Contractor shall adequately protect equipment from damage after delivery to the project. Equipment shall be completely covered and secured with heavy tarpaulins, drop cloths or other protective coverings as required to protect from inclement weather, moisture, chemicals, construction traffic, plaster, paint, mortar and/or dirt. Do not cover with plastic materials and trap condensate and cause corrosion. Protective covering is in addition to the manufacturer's original factory packaging. Original factory packaging shall not be deemed as acceptable protection of equipment. D. Do not deliver equipment to the project site until progress of construction has reached the stage where equipment is actually needed or until building is closed in enough to protect the equipment from weather. Equipment allowed to stand in the weather will be rejected, and the contractor is obligated to furnish new equipment of like kind at no additional cost to the Owner. Limit shipment of bulk and multi-use materials to quantities needed for immediate installation. E. Comply with manufacturer's installation instructions for rigging, unloading, and transporting units. F. Protect units from physical damage. Leave factory covers in place until startup of machine. 1.11 REQUIRED FIELD UNIT LEAKAGE AND DEFLECTION TEST A. After the unit has been set and leveled, and prior to installation of ductwork, controls, or electrical components, Custom Air Handling Unit Manufacturer's direct representative shall perform a field air leakage and cabinet deflection test. Cabinet leakage rate shall not exceed 1% of total design airflow and L/200 deflection at +8" W.C.Field test shall be conducted by the manufacturer, or local representative, and witnessed by the Engineer and owner's representative. Up to four panels shall be measured for deflection at the mid-point of the panel joints. Manufacturer or local manufacturer's representative shall provide a full report showing full compliance and signed by the manufacturer or manufacturer's local representative. Provide the owner, engineer, and contractor a copy of passing report. Additional work to the unit cannot be conducted until unit successfully passes leakage test. The leakage test shall not be performed by the installing contractor. CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 23 73 13.19-4 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas COMPLY 1.12 WARRANTY A. Furnish one (1) year manufacturer parts and labor warranty for air handling units. Warranty shall begin from date of Certificate of Substantial Completion. Warranty start date from shipment or start up is not acceptable. 1.13 EXTRA MATERIALS A. Furnish extra materials that match products installed and that are packaged with protective covering for storage and identified with labels describing contents. Spare materials shall be provided by equipment manufacturer and not by the installing mechanical contractor or "By Others". Extra materials shall be clearly labeled by unit name in protective container and delivered to the City of Pearland Maintenance and Operations for attic stock. 1. Filters: Three (3)sets for each unit. One set during construction, a new set of filters for Test and Balancing services, and final new set at substantial completion. Filters shall be protected with polyester fabric at all times during construction. 1.14 COORDINATION A. Coordinate sizes and locations of concrete bases with actual equipment provided. B. Coordinate sizes and locations of structural-steel support members, if any, with actual equipment provided. PART 2 - PRODUCTS 2.1 CUSTOM HYDRONIC POOL DEHUMFICATION AIR-HANDLING UNITS A. Manufacturers: Subject to compliance with scheduled efficiencies, capacities, and specification, provide products by tthel following manufacturers. 1. Temtr.....1..:..m ry qq y 2. JCI Custom. 3. Climate Craft. 4. Energy Labs Inc. 5. Engineered Air. B. Configuration: Coordinate with project plans and schedules. C. Performance Base: Sea level pressure or altitude. D. Fabrication: Conform to AMCA 99 and ARI 430. Units shall be factory assembled and ship in one piece where possible. Shipping splits are acceptable provided manufacturer includes gaskets and bolts. E. Refer to Equipment Schedule for maximum allowable dimensions. Submitted Custom Air Handling Units shall not exceed scheduled length,width, height, and weight. F. If equipment other than the equipment listed as "Basis of Design" is provided, it is the mechanical contractor's responsibility to confirm that submitted equipment meets scheduled performance, equipment footprint does not exceed scheduled maximum allowable dimensions or scheduled maximum allowable weight and that all applicable CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 23 73 13.19-5 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas COMPLY piping and duct connections such as but not limited to supply, return, exhaust, and outside air do not deviate from plans. 2.2 SPECIAL PROJECT REQUIREMENTS: CONSTRUCTION A. The Custom air handling units shall be constructed to fit scheduled maximum dimensions including factory built mixing boxes and must maintain minimum specified access sections as scheduled and shown on plans. Rotating units to different orientations other than what is drawn on plans will be unacceptable. Units exceeding any scheduled dimension will not be accepted. B. The custom air handling units shall be designed for rapid knock-down construction for installation through the existing 8'-0" tall x 8'-0" wide louver. The custom air handling unit manufacturer must submit a history of knock-down & rebuild projects where the units have successfully passed field leakage and deflection tests after assembly. C. The custom air handling unit manufacturer shall provide a minimum of 5 days of field labor assistance during assembly. Coordinate time with owner and engineer to field verify and witness; provide a minimum of(5)five business day's notice. D. Supply air connection, return air connection, and exhaust air connection must match the existing unit location and size; existing supply, return, and exhaust duct openings are to remain therefore openings must match; manufacturer must make a field visit and take all opening measurements and not exceed plan dimensions and weight. 2.3 PRINCIPLE OF OPERATION A. The unit shall be designed and sized to maintain the specified space temperature and relative humidity at all conditions. The unit shall be able to simultaneously provide cooling for space dehumidification and reheat for space temperature control. B. The unit operation shall be as follows: 1. During space conditioning mode, the purge fans are disabled, the purge fan dampers are closed, the outdoor air damper is opened to the TAB adjusted minimum position, the return air damper is opened to the TAB adjusted maximum position, and the supply fans are enabled. a. The outdoor air and return air mixes and passes through the chilled water cooliing coil, is cooled below its dew point,thereby condensing moisture. The cooling coil control valve is modulated to maintain the active cooling coil setpoint. b. The hot water reheat coil control valve is modulated to maintain the active supply air temperature setpoint,which is reset based on space temperature. 2. During purge mode,the purge fans are enabled,the purge fan dampers are opened,the outside air dampers are fully opened,the return air dampers are closed, and the supply fans are enabled. a. The chilled and hot water control valves are closed. CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 23 73 13.19-6 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas COMPLY 2.4 CASING A. Full perimeter welded double-bottom steel base assembly constructed with a minimum of A500 structural steel tubing, phenolic coated for minimum 2,500-hour salt spray resistance per ASTM B117-95 and shall be a minimum of six (6) inches in height. Welded 14-gauge C- channel cross supports shall be located on maximum 24" centers. Base assembly shall include a thermal break and shall be insulated with a minimum of 4" thick, R-32 closed-cell sprayed foam to ensure air/water-tight construction. Assemble multiple sections with gaskets and bolts and caulk all seams after assembly. B. Outside Casing: 1. Aluminum: Minimum 0.063" 16-gauge stucco embossed with minimum 2" thick, R- 13 expanded foam injected insulation and coated to exceed a 2,500-hour salt spray resistance per ASTM B117-95. C. Inside Casing: 1. Aluminum: Solid minimum 0.040" (18-gauge) and coated to exceed a 2,500-hour salt spray resistance per ASTM B117-95. D. Floor and Subfloor: 1. Aluminum Treadplate Floor: Minimum 0.100" (10-gauge) and coated to exceed a 2,500-hour salt spray resistance per ASTM B117-95. 2. Solid Aluminum Subfloor: Minimum 0.040" (18-gauge) and coated to exceed a 2,500-hour salt spray resistance per ASTM B117-95. E. Structure/rolled tubes to be coated to exceed a 2,500-hour salt spray resistance per ASTM B 117-95. F. Casing shall be supported by free-standing 16-gauge G90 galvanized steel structural frame with removable panels. Framing members shall be painted to exceed a 2,500-hour salt spray resistance per ASTM B117-95 or constructed of stainless steel, have thermal break, and injected with expanded foam insulation. Structural integrity of frame shall not be affected by removing panels. Top, bottom, and side panels shall be of one-piece double-wall construction, formed and reinforced to provide a rigid assembly. All panels shall be completely gasketed at factory with a minimum 1/4-inch-thick x 3/4 inch wide closed-cell neoprene. Top and side panels shall be easily removable for service. G. Insulation: Minimum R-24 Expanded Foam-in-Place Construction. 1. `K' (Ksi) factor at 75 degrees Fahrenheit: Maximum 0.125 Btuh inch / sq. ft. / degrees Fahrenheit. 2. Density: Two (2)inch thick, minimum 3 lbs./cu ft. density throughout the entire unit. 3. If air unit structural frame comes into contact with conditioned air, it shall be insulated with the same material throughout the rest of the unit. 4. Panels constructing which utilize foam board are not acceptable. H. Access Section: 24" access section with minimum 21" door (refer to details) in coil sections and 27" doors in fan sections. Access door and window frames shall be foam CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 23 73 13.19-7 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas COMPLY insulated, include a thermal break, and constructed of aluminum. Access doors shall match the construction and materials of the unit casing and include dual automotive neoprene gaskets, latch and handle assembly, and stainless-steel adjustable mounting hardware. Provides access doors with windows between parallel coil sections, mixing sections, filter sections, and fan sections. I. Drain Pans: Drain pans shall be included for both chilled and hot water coils. Drain Pans shall be 16-gauge #316 stainless steel pans with minimum four (4) inch R-32 expanded foam insulation and welded corners. Drain pans without welded corners are not acceptable. Cross break and pitch to drain connection. Cooling coils with a finned height greater than 48 inches shall have an intermediate 16-gauge #316 stainless steel drain pan extending entire length of coil. Intermediate pan shall have a minimum of two drop tubes to main pan. Drain pans shall allow no standing water and comply with ASHRAE Standard 62. Drain pans must be accessible for cleaning. Drain pan connection is to be#316 stainless steel. J. Strength: Furnish structure to brace casings for suction pressure of eight (8) inch wg, with maximum deflection of 1 in 200. K. Panel Screws: All panel screws shall be stainless steel or epoxy coated steel. 2.6 BLOWER A. Type: Refer to Air Handling Unit Schedule for fan type and drive type. 1. Direct drive plenum fans shall be single width single inlet type with backward inclined airfoil blades. Plenum fan wheel, airfoil blades and hub shall be constructed from welded aluminum. Entire fan assembly shall be polymer epoxy E-coated for superior corrosion resistance. B. Fan shall be statically and dynamically balanced at the factory as a complete fan assembly. C. The Fan wheels shall be keyed to shaft to prevent slipping. D. Construction:AMCA Class III minimum. E. Performance Ratings: Conform to AMCA 210 and label with AMCA Certified Rating Seal. F. Sound Ratings: Tested to ARI 260 and label with Certified Sound Rating Seal. G. Bearings: Provide permanently lubricated bearings. H. Mounting: Locate fan and motor internally on welded steel base coated with corrosion resistant paint and factory-mounted motor on slide rails. Furnish access to motor, drive, and bearings through hinged access doors. For fan/motor assemblies balanced to meet AMCA Standard 204-96 that do not meet or exceed category BV-5, mount fan array base on vibration isolators with deflections in accordance with Section 23 05 48 - Vibration and Seismic Controls for HVAC Piping and Equipment or 2" deflection, whichever requirement is stricter Vibration &seismic controls shall be coated for corrosion resistance. I. Fan Modulation: Variable frequency drive. J. Fan Motors: All motors shall be premium efficiency, NEMA MG-1 Section 3, Inverter Duty, Totally Enclosed Air Over (TEAO). Refer to Specification 23 05 13 - Common Motor CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 23 73 13.19-8 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas COMPLY Requirements for HVAC Equipment for acceptable motor manufacturers. ECM motors are not acceptable. K. Flexible Connection: Provide internal flexible connection between fan and air unit casing. Flexible connection between air unit casing and connecting duct shall not be provided when fan is internally isolated with flexible connection to casing. L. Fan Array Systems shall be designed for full cabinet face area airflow distribution. At a minimum, provide the number of fans scheduled to achieve a 90% cross sectional area distribution. M. Each fan/motor cube, intake wall, inlet cone, and motor support rail shall be constructed of minimum 14-gauge G90 galvanized steel or aluminum and coated to exceed a 2,500-hour salt spray resistance per ASTM B117-95. Alternately, fan/motor cube and intake wall shall be constructed of stainless steel for corrosion protection. N. All fan/motor cubes shall be provided with zero net effect vertical aluminum backdraft dampers in aluminum frame. These non-controlled dampers shall provide for isolation in event a fan fails or is turned off and to prevent filters from being pulled into the fan section. O. All fan/motor cubes shall have perforated liners with melamine insulation for sound attenuation. 2.6 BEARINGS AND DRIVES A. Bearings: Pillow block type, self-aligning, grease-lubricated ball bearings, with ABMA 9 L-10 life at 300,000 hours. B. Shafts: Solid, hot rolled steel, ground and polished, with key-way, and protectively coated to prevent corrosion. C. Motor Shaft Grounding Kit: For all AHU motors, a motor shaft grounding kit shall be provided. This shall be factory installed prior to shipment. If not available from the factory, manufacturer is responsible for providing kits and field installation with no additional cost to owner or contractor. D. Motor: Motor shall be non-overloading. Motor horsepower shall be sized at a point on fan curve resulting from 105 percent of design RPM at scheduled CFM with a reduction in static pressure of 0.5-inch wg. All fan motors shall be in accordance with Section 23 05 13 - Common Motor Requirements for HVAC Equipment. 2.7 CHILLED & HOT WATER COILS A. Provide access doors upstream and downstream of coils. Enclose coils with headers and return bends fully contained within casing. Slide coils into casing through removable end panel with coated blank-offs and casing sealing grommets at connection penetrations. Coils shall be supported by coated G90 galvanized steel coil support members maintaining a minimum of 1"separation between bottom of coil casing and drain pan. B. Air Coils: Certify capacities, pressure drops, and selection procedures in accordance with ARI 410. C. Water Re-Heating Coils: 1. Headers: Seamless copper tube with brazed joints. CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 23 73 13.19-9 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas COMPLY 2. Configuration: Drainable, with threaded plugs for drain and vent; serpentine type with return bends on smaller sizes and return headers on larger sizes. 3. 24-inch access section between parallel coil faces. 4. Casing: Die formed channel frame of 16-gauge galvanized steel. 5. Tubes: 5/8-inch OD seamless copper expanded into fins, brazed joints. Minimum tube thickness shall be 0.020" copper. 'h"OD tubes will not be acceptable. 6. Fins: Aluminum, maximum of 10 fins per inch. Minimum fin thickness shall be 0.008" aluminum. 7. Entire coil, including casing and coil supports, shall have a factory applied post- construction, flexible, epoxy polymer e-coat uniformly applied to all coil surface areas without material bridging between fins. Humidity and water immersion resistance shall be up to a minimum 1,000 and 250 hours respectively (ASTM D2247-92 and ASTM D870-92). Corrosion durability shall be confirmed through testing to no less than 6,000 hours salt spray per ASTM B117-90. Coated coils shall receive a spray-applied, UV-resistant polyurethane topcoat to prevent UV degradation of the e-coat. Pre-Coated fin stock nor field applied coating will be acceptable. D. Water Cooling Coils: 1. Headers: Seamless copper tube with brazed joints. 2. Configuration: Drainable, with threaded plugs for drain and vent; threaded plugs in return bends and in headers opposite each tube. 3. Coils shall be a maximum of eight(8) rows deep. 4. 24-inch access section between parallel coil faces. 5. Casing: Die formed channel frame of 16-gauge galvanized steel. 6. Drain Pans: Extend 24 inches downstream of coil and for coil banks more than 48 inches high provide intermediate pan with down spouts. 7. Tubes: 5/8-inch OD seamless copper expanded into fins, brazed joints. Minimum tube thickness shall be 0.020" copper. 'h"OD tubes will not be acceptable. 8. Fins: Aluminum, maximum of 10 fins per inch. Minimum fin thickness shall be 0.008" aluminum. 9. Coil supports shall be galvanized steel coated to match unit casing specifications. 10. Entire coil, including casing and coil supports, shall have a factory applied post- construction, flexible, epoxy polymer e-coat uniformly applied to all coil surface areas without material bridging between fins. Humidity and water immersion resistance shall be up to a minimum 1,000 and 250 hours respectively (ASTM D2247-92 and ASTM D870-92). Corrosion durability shall be confirmed through testing to no less than 6,000 hours salt spray per ASTM B117-90. Coated coils shall receive a spray-applied, UV-resistant polyurethane topcoat to prevent UV CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 23 73 13.19- 10 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas COMPLY degradation of the e-coat. Pre-Coated fin stock nor field applied coating will be acceptable. E. Tube Velocities: Coil tube design velocity shall be between 2 feet and 5 feet per second and also maintain design water side temperature difference down to 30 percent flow through coil. Provide tubes that are enhanced internally if minimum initial design tube velocity cannot be obtained. 2.8 FILTERS A. Filter Box: Section with filter guides, access doors as shown on plans, for face loading with gaskets and blank-off plates. Filter frame assembly shall be constructed of 16-gauge galvanized steel or aluminum and painted to exceed a 2,500-hour salt spray resistance per ASTM B117-95. Alternately, filter frame assembly shall be constructed of 16-gauge #316 stainless steel. B. Replaceable Filter Media: MERV 11 or greater rating in accordance with ASHREA Test Standard 52.2-2007. C. High-Capacity Filter: Two (2) inch extended area filters. Air quantities as scheduled; clean pressure drop of 0.10 inches wg; dirty pressure drop of 0.75 inches wg. D. Filter Area: Max velocity of 500 FPM. 2.9 DAMPERS A. All dampers shall be factory installed and constructed of heresite coated aluminum. B. Provide Class 1A rated, ultra-low leak dampers (less than 3 cfm/sq ft. @ 1" w.g.). Low leakage dampers shall have extruded aluminum airfoil blades mounted in a 6063T5 extruded aluminum frame. Flat or formed metal blades are not acceptable. The damper blade shall incorporate ruskiprene edge seals and zinc plated or stainless-steel tubular steel shaft for a non-slip operation. Shaft bearings shall be spherical molded synthetic to eliminate friction and any metal-to-metal contact. Damper jamb seals shall be UV rated, nylon glass reinforced designed for a minimum air leakage and smooth operation. Damper operators shall be provided, installed, and wired by the BAS subcontractor. 2.10 CONTROLS A. Controls: Refer to Section 23 09 23 -Direct-Digital Control System for HVAC. 2.11 CAPACITY A. Performance: Provide equipment as scheduled on Drawings. 2.12 ELECTRICAL CHARACTERISTICS AND COMPONENTS A. Provide equipment with electrical characteristics as shown on Electrical Drawings. B. Section 23 05 13 - Common Motor Requirements for HVAC Equipment: Requirements for motors. C. Section 23 05 14 -Variable Frequency Controllers: Requirements for drives. D. Motor Overload Panel: For units with more than one fan, and to allow for a connection to a single variable frequency drive, provide a factory mounted and wired motor overload CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 23 73 13.19- 11 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas COMPLY panel. Panel shall be UL listed, NEMA 4 enclosure with IECC manual starters with rotary type operators and auxiliary contacts. E. All starters shall be equipped with integral phase-failure relay (automatic resetting type) to shut down motor upon loss of an electrical phase. F. Marine Lights: Each section with an access door shall include a LED marine light. Wire all lights to a single light switch located adjacent to the fan section access door. G. 120v / 1 ph /60hz GFCI Convenience Outlets: Provide one outlet adjacent to the fan section access door. H. All internal electrical and controls conduit shall be constructed of aluminum and include aluminum or coated steel supports and hardware. 2.13 SOURCE QUALITY CONTROL A. Fan Sound-Power Level Ratings: Comply with AMCA 301, "Methods for Calculating Fan Sound Ratings from Laboratory Test Data." Test fans according to AMCA 300, 'Reverberant Room Method for Sound Testing of Fans." Fans shall bear AMCA-certified sound ratings seal. B. Fan Performance Rating: Factory test fan performance for airflow, pressure, power, air density, rotation speed, and efficiency. Rate performance according to AMCA 210, "Laboratory Methods of Testing Fans for Aerodynamic Performance Rating." C. Water Coils: Factory tested to 300 psig according to ARI 410 and ASHRAE 33. D. Refrigerant Coils: Factory tested to 450 psig according to ARI 410 and ASHRAE 33. PART 3 - EXECUTION BY M.C. 3.1 INSTALLATION A. Install in accordance with ARI 430. B. Install assembled units with internal vibration isolators. Internally isolated fans shall be provided with resilient mountings and flexible electrical leads. Install restraining snubbers as required. Adjust snubbers to prevent tension in flexible connectors when fan is operating. Refer to Section 23 05 48 -Vibration and Seismic Controls for HVAC Piping and Equipment. C. Equipment Mounting: Install air-handling units on concrete bases using elastomeric pads. Secure units to anchor bolts installed in concrete bases. Comply with requirements for concrete bases; Comply with requirements for vibration isolation devices specified in Section 23 05 48 "Vibration and Seismic Controls for HVAC Piping and Equipment." D. Contractor to provide fixed sheaves required for final air balance as dictated by Test and Balance Contractor. E. Do not operate fan system until filters (temporary or permanent) are in place. Replace temporary filters used during construction and testing, with new, clean filters. F. Insulate coil headers located outside airflow as specified for piping. Refer to Section 23 07 19- HVAC Piping Insulation. CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 23 73 13.19- 12 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas BY M.C. G. Provide trapped condensation drain line routed to the nearest floor drain. Refer to detail on Drawings and Section 23 21 13- Hydronic Piping. H. Installation of Hot Water Heating and/or Chilled Water Coil: 1. Make connections to coils with unions. Position unions to permit coil removal. 2. Connect water supply to leaving airside of coil (counter flow arrangement). 3. Locate water supply at bottom of supply header and return water connection at top. 4. Install water coils to allow draining and install drain connection at low points. 5. Install the following piping accessories on piping connections. Refer to Section 23 21 13- Hydronic Piping. a. On supply: (refer to details) 1. Thermometer well and thermometer. 2. Well for control system temperature sensor. 3. Shutoff valve. 4. Pressure gage. 5. Strainer b. On return: (refer to details) 1. Air vent. 2. Thermometer well and thermometer. 3. Well for control system temperature sensor. 4. Pressure gage. 5. Modulating control valve. 6. Flow control balancing valve. 7. Shutoff valve. 6. Install valves and piping specialties in accordance with details as indicated on Drawings. 7. Install manual air vents at high points complete with shutoff valve. Refer to Section 23 21 13 -Hydronic Piping. 8. Install floor support stands at piping drops to air unit coil connections. Air unit coil shall not carry any suspended piping load. I. Air unit manufacturer representative shall remove vibration isolation shipping blocks prior to start-up and ensure that fan base is free floating, and isolators are not short-circuited during operation. 3.2 CONNECTIONS A. Coordinate piping installations and specialty arrangements with schematics on Drawings and with requirements specified in piping systems. If Drawings are explicit enough, these requirements may be reduced or omitted. B. Comply with requirements for piping specified in other Sections. Drawings indicate general arrangement of piping, fittings, and specialties. CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 23 73 13.19- 13 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas BY M.C. C. Install piping adjacent to air-handling unit to allow service and maintenance. D. Connect piping to air-handling units mounted on vibration isolators with flexible connectors. E. Coordinate duct installations and specialty arrangements with schematics on Drawings and with requirements specified in Section 23 31 13 "Metal Ducts" and Section 23 33 00 "Air Duct Accessories." F. Connect duct to air-handling units with flexible connections. Comply with requirements in Section 23 33 00 "Air Duct Accessories." COMPLY 3.3 FIELD QUALITY CONTROL A. Manufacturer's Field Service: Engage a factory-authorized service representative to inspect, test, and adjust components, assemblies, and equipment installations, including connections. B. Perform tests and inspections. 1. Manufacturer's Field Service: Engage a factory-authorized service representative to inspect components, assemblies, and equipment installations, including connections, and to assist in testing. BY M.C. C. Tests and Inspections: 1. Leak Test: After installation, fill water coils with water, and test coils and connections for leaks. 2. Fan Operational Test: After electrical circuitry has been energized, start units to confirm proper motor rotation and unit operation. 3.4 STARTUP SERVICE A. Perform startup service. 1. Complete installation and startup checks according to manufacturer's written instructions. 2. Verify that shipping, blocking, and bracing are removed. 3. Verify that unit is secure on mountings and supporting devices and that connections to piping, ducts, and electrical systems are complete. Verify that proper thermal- overload protection is installed in motors, controllers, and switches. 4. Verify proper motor rotation direction, free fan wheel rotation, and smooth bearing operations. Reconnect fan drive system, align belts, and install belt guards. 5. Verify that bearings, pulleys, belts, and other moving parts are lubricated with factory-recommended lubricants. 6. Verify that zone dampers fully open and close for each zone. 7. Verify that face-and-bypass dampers provide full face flow. CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 23 73 13.19- 14 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 LEAF Engineers Pool Unit Replacement at Recreation Center and Natatorium Project No. 220346 City of Pearland, Texas BY M.C. 8. Verify that outdoor- and return-air mixing dampers open and close and maintain minimum outdoor-air setting. 9. Comb coil fins for parallel orientation. 10. Verify that proper thermal-overload protection is installed for electric coils. 11. Install new, clean filters. 12. Verify that manual and automatic volume control and fire and smoke dampers in connected duct systems are in fully open position. B. Starting procedures for air-handling units include the following: 1. Energize motor; verify proper operation of motor, drive system, and fan wheel. Adjust fan to indicated rpm. Replace fan and motor pulleys as required to achieve design conditions. 2. Measure and record motor electrical values for voltage and amperage. 3. Manually operate dampers from fully closed to fully open position and record fan performance. 3.6 ADJUSTING A. Adjust damper linkages for proper damper operation. B. Comply with requirements in Section 230593 "Testing, Adjusting, and Balancing for HVAC" for air-handling system testing, adjusting, and balancing. 3.6 CLEANING A. After completing system installation and testing, adjusting, and balancing air-handling unit and air-distribution systems and after completing startup service, clean air-handling units externally and internally to remove foreign material and construction dirt and dust. Clean fan wheels, cabinets, dampers, comb coils, drain pans, and filter housings, and install new, clean filters. COMPLY 3.7 DEMONSTRATION A. Train Owner's maintenance personnel to adjust, operate, and maintain air-handling units. BY M.C. 3.8 PROTECTION OF FINISHED WORK A. Do not operate units until ductwork is clean, filters are in place, bearings lubricated, and fan has been test run under observation. B. All air units shall remain in manufacturer's protective shipping wrap during construction. Air unit casing openings must remain protected and covered during construction. If protective wrap has been damaged, the contractor shall provide additional protective wrap as directed by engineer. END OF SECTION CUSTOM HYDRONIC POOL DEHUMIDIFICATION UNITS 23 73 13.19- 15 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 1111111111111TEK ,V1 _____,AtoF,oih,�V ii tltltltlti AIR -1 1.... �I ulna II urn°iI una ur„ CITY OF PEARLAND NATATORIUM � � vNfli��r 1nr G% ��11Ulo ,ilk Generated Date: 2023-08-09 �ii 1 IYIr�rII!JI �ryjj(�(Ip/ Iry Revision: P1 00111, QUOTE# 22-0168 EQUIPMENT NAHU-01_R2, NAHU-02_R2 REPRESENTATIVE J. CHASE WILLIAMSON TEXAS AIR SYSTEMS 9021 S. SAM HOUSTON PKWY W. i SUITE 100 MISSOURI CITY, TX 77489, USA Phone: (832)342-7004 Email: chase.williamson@texasairsystems.com �I, SALES APPLICATIONS Burke Lucas CONTACT Phone: (405)763-5518 r Email: Burke.Lucas@nortek.com IMPORTANT NOTICE ABOUT THIS SUBMITTAL: This revision supersedes previous revisions.Approval of this submittal indicates that it has been thoroughlyreviewed and approved by all relevant mechanical, electrical, and structural disciplines involved in the project.The equipment Nortek Air Solutions proposes to furnish will be produced in accordance with the contents of this submittal. Nortek Air Solutions is not responsible or liable for features or performance requirements included in plans&specifications that were not furnished to Nortek Air Solutions prior to the preparation of this submittal. An approved and/or reviewed submittal, returned to Nortek Air Solutions with a "Release For Production", shall be deemed to be in essential compliance with plans & specifications and shall be manufactured in accordance with the contents of this This document is confidential,copyrighted submittal. In the event of any discrepancy between this submittal and plans & and property of Nortek Air Solutions, LLC. specifications or other contract documents, this submittal will control. Approved By: Signature of Responsible: Date Name of Responsible( Print): Title: Generated By: Burke Lucas, Nortek Air Solutions: Okarche DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 A&r,,4W"1V IME.XR.............�N............ILK,, Table of Contents AI F-1 S 0 LJ"F�CD S ............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................. F E INNA I F-1 0 1 Unit Designs NAHU-01—R2 . . . . . . . . . . . . . . . . . . . . . 4 Unit Design Options . . . . . . . . . . . . . . 9 Fans . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Coils . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Components . . . . . . . . . . . . . . . . . . . . 25 Electrical . . . . . . . . . . . . . . . . . . . . . . . 29 NAHU-02—R2 . . . . . . . . . . . . . . . . . . . . . 33 Unit Design Options . . . . . . . . . . . . . . 38 Fans . . . . . . . . . . . . . . . . . . . . . . . . . . 43 Coils . . . . . . . . . . . . . . . . . . . . . . . . . . 51 Components . . . . . . . . . . . . . . . . . . . . 54 Electrical . . . . . . . . . . . . . . . . . . . . . . . 58 Terms and Conditions . . . . . . . . . . . . . . . 62 Date/Revision:2023-08-09/Rev. P1 106 IN Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 000uSig 400Fo63o-7Aoo-41131'o32F-oEocA9573co9 N��N��~�N��~��N��N�� Unit^� Design Revision History ^�N�' ����r � ���m�'m�� � m������ A IFq S 0 Il LJ7-|CD S TE L PROJECT CITY OFPEARLAND NATATORIUM RENOVATION OUOTE# 22-0108-005 UN|TTAG NAHU-01_R2 QUANTITY 1 Date Rev Revision Description 2022-12-30 2 ALUMINUM CONSTRUCTION ouxynev/,/vn:xoo'oo-0s/Rev.p1 1oow Industrial Blvd.ouamxe.oxrzrox Design Assistant Unit Design Revision x (4os)o1r'smo FAX(4os)xoz-4soo s.o.z/x.o.o.x This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 5 - \ \_ \ \ JEF MOP'r \d = 6R : w2 2 ] ( po - e -- iC « r--- r hON® L ) \ ~ � / I I ILT- -----©--- T-T- � \ ---- ----- g ° ^~ ----------- »� ----------- , \ « , -MH \ <- \\\\ 22 \_ _____ ? ƒ `2 ? � • ~ ° \\ : \ / AL� / IL� / \� \ \ 7 69& » § rm z» m ~ \ � \ � \ §« o o — LLJ Ld 9 .............................. IVY t 3 W j v............... ........... ---------- g 0 (CIO LO 0) < co LLI 9 LL I�X I .............................................. LL CL 0 ui C: 2M U) 60-90-CZOZ :(PP-NN-AAAA) PGIUIJd 0 0 2 z K= - 9 - / LLJ g } \a ok 2 a _ m z /` A / ¥\ L « - + / \\ / \- � \ / §\ g < \ /Qj~ ) - -_ 3 } \ � \ § < / / � G E \ \ e � 9 a CL f G 80-e0-EZOz }PmRR77% PG mNd 0 2 z K= - 9 - / LLJ g } \a ok / y 3 \ / d . .......... ......_ � � / & \ a ] \ m = K L « - \ / \\ / \- � \ / §\ g \ /Qj~ jLLI § \ G m § \ / / � § ± CL a 3 f G 80-e0-EZOz }PmRR77% PG mNd 0 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 A&r,,4W"1V IME.XR.............I............LEK,, AI F-1 S 0 Il LJ"F�CD S ............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................. F E INNA I Fl 0 1 PROJECT CITY OF PEARLAND NATATORIUM RENOVATION QUOTE# 22-0168-005 UNIT TAG NAHU-01—R2 QUANTITY 1 Unit Design Options Date/Revision:2023-08-09/Rev. P1 106 IN Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 10 DocuSign Envelope ID:4DDFB63B-7ADO-41 B1-B32F-OEBCA9573CB9 �1' � I �.I VK- III' ul� �I°iI ulm °iI ui m ur„ r.,(I? i.;r;is 1 ff l e P. Unit Design Options Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 A4A4 iiu, . 100.1 Electrical 1. Short Circuit Current Rating(SCCR)@ 65 kA Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 11 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1` JR�.�T SUE l III"C III III mi III IIY fi Ilt„ r.,(I? i.;r;is 1 ft l e P. Unit Design Options Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 1 �Illu 101.1 Weights I Jobsite Elevation 1. Shipping Weight 120,298 lb 113. Elevation loft 2. Operating Weight 120,953 lb 101.2 Preparation for Shipment KNOCKDOWN CONSTRUCTION -Unit to be shipped assembled with minimum screws/bolts 1. Knockdown Construction from Factory. Unit disassembly and re-assembly by"OTHERS" in the Field. Unit to be caulked by"OTHERS" in the Field. 101.3 KID Field Opening Size 1.Height 2.Width 3.Depth in 1 m 102.1 Construction 1. Cabinet Construction ITF- Integrated Frame 16. Thermal Break Modified Thermal Break 2. Design Environment Indoor 17. Mounting Slab Mounted 3. Panel Depth 3 in 4. Caulk Type Standard 5. Model# 102.2 Cabinet Material 1. Exterior Material 0.063 Alum Pre-Paint 7. Blankoff Finish Pre-Paint(See Exceptions) 2. Interior Liner type(s) See Drawing 8. Internal Wall Material 116Ga Galy Pre-Paint 3. Exterior Paint Type Pre-Paint Insulation by liner type 4. Interior Paint Type Pre-Paint 9. Solid liner Polyurethane Foam (R24) 5. Paint Color Sandstone 6. 5000 Hr Salt Spray IND Exceptions: 1. Chilled Water Coil: blankoff material is 16Ga 316 SS 2. Hot Water Reheat Coil: blankoff material is 16Ga 316 SS 3. Filters: blankoff material is 16Ga 316 SS, blankoff finish is None 102.3 Base Construction 1. Base Structure Material Steel Tube 6. Base Structure Height See Drawing 2. Base Floor Material 0.100 Alum Treadplate Pre-Paint 7. Sub Floor Material 0.040 Alum Pre-Paint 3. Insulation Polyurethane Foam 8. Floor Coating None 4. Floor Drain None 9. Lifting Lugs Yes-Welded 5. Floor Options None 102.4 Box Dimensions Box X Y Z Shipping Weight Operating Weight A 88.500 in 128.000 in 136.500 in 5,642 lb 5,547 lb B 85.000 in 128.000 in 136.500 in 3,043 lb 3,043 lb C 41.000 in 128.000 in 136.500 in 2,976 lb 3,649 lb D 37.000 in 128.000 in 136.500 in 1,935 lb 2,184 lb E 68.500 in 128.000 in 136.500 in 6,075 lb 5,903 lb 102.5 Notes I Features 1. Box dimensions do not include lifting lugs, electrical panels, pipe connections, door handles, etc. 103.1 All Doors(including those associated with specific components) # I Box I Section I Type' I Width I Height I Hinge I Swing I Window I Interior I Exterior 1 1 A I FWT2 1 3"TBF 1 27 69 RH In 10 x 10 TB 10.063 Alum Pre-Paint 10.063 Alum Pre-Paint Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 12 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1` JR�.�T SUE l III"C III III mi III IIY fi Ilt„ r.,(I? i.;r;is 1 ft l e P. Unit Design Options Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 # Box Section Type' Width Height Hinge Swing Window Interior Exterior 2 B PL1 3"TBF 24 72 LH Out None 0.063 Alum Pre-Paint 0.063 Alum Pre-Paint 3 B PL2 3"TBF 24 72 LH Out None 0.063 Alum Pre-Paint 0.063 Alum Pre-Paint 4 C CW1 3"TBF 21 72 RH Out None 0.063 Alum Pre-Paint 0.063 Alum Pre-Paint 5 D HW1 3"TBF 21 72 RH Out None 0.063 Alum Pre-Paint 0.063 Alum Pre-Paint 161 E I FWT1 1 3"TBF 1 27 72 1 LH I In I 10 x 10 TB 10.063 Alum Pre-Paint 0.063 Alum Pre-Paint 103.2 Notes/Features 1. Door Types TBF=Thermal Break Factory 2. All doors insulated with Polyurethane Foam. P. Options: SP=Sensor Port, TO=Tool Operated Handle 1 �Illu 104.1 All Drains(including those associated with specific components) Box Section Type Conn(in) Hand Grating Material Pan Material C CW1 Drain Pan 2.00 Right None 16Ga 316 SS D HW1 Drain Pan 1.25 Right None 16Ga 316 SS 104.2 Notes/Features 1. Drain Constructions included: Triple Pitched 1 105.1 All Internal Walls(including those associated with specific components) Box Section Wall Name Depth Panel Mat. Liner Mat. Insulated B Mixing Plenum InternalWall 2 in Default 16Ga Galy Pre-Paint True Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 13 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR�.�TIEK— III"C III 11111i III IIY fi Ilt„ r.,(I? i.;r;is 1 ff l e P. Unit Design Options Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 106.1 DESIGN 106.1.1 Unassigned Tunnel Description APD(in.H2O) Supply Air Tunnel JPOA Opening-Damper(Outside Air) 0.04 Total Static Pressure: 0.04 106.1.2 SUPPLY AIR Tunnel Description APD(in.H2O) Return Air Tunnel Main RA Opening 1 (Return Air) 0.00 Supply Air Tunnel RA Opening 1 -Damper(Return Air) 0.18 Supply Air Tunnel OA Opening 1 -Damper(Outside Air) 0.03 Supply Air Tunnel 2" MERV 11 Filters(CLEAN) 0.25 Supply Air Tunnel 2" MERV 11 Filters(DIRTY) 0.50 Supply Air Tunnel Chilled Water Coil 0.69 Supply Air Tunnel Hot Water Reheat Coil 0.15 Supply Air Tunnel FANWALL 1 (Supply)46,500 SCFM @ 3.40 in.H2O 0.00 Supply Air Tunnel SA Opening 1 (Supply Air) 0.10 EXTERNAL STATIC PRESSURE (SUPPLY AIR) 1.50 Total Static Pressure: 3.40 106.1.3 Exhaust Tunnel Description APD(in.H2O) Purge Air Tunnel FANWALL 2(Exhaust)46,500 SCFM @ 1.29 in.H2O 0.00 Purge Air Tunnel EXH Opening 1 (Exhaust Air) 0.29 EXTERNAL STATIC PRESSURE (EXHAUST AIR) 1.00 Total Static Pressure: 1.29 Legend: ESP-External Static Pressure, OSA-Outside Air, EXH -Exhaust Air, RA-Return Air, SA-Supply Air 106.2 Notes/Legend 1. Summary report does not include static pressure of components supplied by others in the field unless otherwise noted. Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 14 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 w. ,.o q F-1 S �_ ��" �CD S F E INNA.I....pw l 0 V..., PROJECT CITY OF PEARLAND NATATORIUM RENOVATION QUOTE# 22-0168-005 UNIT TAG NAHU-01 R2 QUANTITY 1 Fans Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 15 DocuSign Envelope ID:4DDFB63B-7ADO-41 B1-B32F-OEBCA9573CB9 �1' � I �.I VK- III' ui� �I°iI uim °iI ui m ur„ r.,El-0 `;r,is f/T f t;P:, Fans Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 200.1 Configuration/Quantity 1. Function Supply Fan Cell Size 5.Height 6.Width 7.Depth 8.Overall Depth 2. Quantity 9 40 38 1 28 35.25 3. Array 3 Rows x 3 Cols 9. Elev./Temp. 0 ft/52.0°F 4. Construction PentaCube 10.Motor&Wheel Weight 201 lb 112.Redundant 0 11.Fan Cell Weight 366 Ib 113.Empty 0 14.Ship Loose Fan(Wheel, Motor and Mounting Base) 0 200.2 Options 1. Coplanar Insulation Standard Melamine 7. Cell Finish None 2. Extended Coplanar No 8. Insulation Retainer No 3. Back Draft Dampers FBD8 9. Inlet Attenuation None 4. Inlet Cone Type A100 Curved Cone 10.Blankoff Material 16Ga Galy Pre-Paint 5. Discharge Safety Guard No 11.Blankoff Finish Pre-Paint 6. Cell Material 1304 Stainless Steel 1112.Removal Rail IYes 200.3 Fan Wheel 1. Wheel Type HPF-A100 1 3. Width 90 2. Diameter 120 1 4. Max RPM 3521 5. Wheel Finish ElectroFin E-Coat 200.4 Motor 1. Manufacturer Baldor 6. Efficiency 90.2 2. HP Each/Total 5/45 7. Service Factor 1.15 3. Poles/RPM 4-Pole/ 1,750 8. Shaft Isolation Ceramic Bearings 4. Frame/Casing 184T/TEAO 9. FLA Each/Total 6.5/58.5 Amps 5. Volts/Phase/Hz 460/3/60 10.Motor HP Safety Factor 3.0 % 200.5 Variable Frequency Drive 1. Quantity 10 113. Maximum Hertz 172.15 2. Voltage 460/3/60 114. Input Line Reactor IND 200.6 Control System 1. Redundant VFD No 15. Flow Monitoring None 2. Drive Standard 16. Fans to Monitor INone 3. Optimization Control No 4. Control Method By Others 200.7 Notes/Features 1. To view patents and other pending U.S. or Canadian applications visit www.nortekair.com/patents. 2. Cone constant=2524, cone flow differential pressure= 5.30 in.1-12O at 5811 CFM per fan. 3. The estimated VFD input watts are based on the motor and VFD efficiency at the selected load and RPM. H. Fans balanced to a maximum allowable level of 0.022 inches per second peak. Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 16 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR�.�T IEu III"C III 1111i3 III Ilia Ilt„ r.,El-0 `;r;is f'T Fans Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 6.3 40 4,' . ° D, ` 3.6 Eiti eile� DESIGha T) 3.2 ' 2 0 a 2.5 T 10 0.6 0 2 0,000 40,00 60,00 ro �r� Airflow cj'FM �i .......... Failed Farr Al l A Licerser, for wua;n5 ar Air Perfornizrce%1,1ithouutAppuarterzrces tlAccessories;1. Ferf rnr�r e ertifie is fc iiirus MIl to i y e:,A:Free IlinlletrFfree O�rtiet Power[bhp)excl udes 6'rives 200.8 Operating Conditions Operating Condition Usage CFM SP(in.H2O) Cell Qty RPM Hz Fanwheel BHP Vel. Watts FEG FEI N I Input Adj. On Off Fail Each Total (ft/min) %O.P. DESIGN 1 146,500 3.40 3.70 9 0 0 1,973 67.6 4.10 36.90 608 31,861 FEG85 0% 1.30 DESIGN w/Failed 1 146,489 3.40 3.79 8 0 1 2,104 72.1 4.84 38.74 684 33,335 FEG85 1% 1.27 Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 17 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I[I'°j' JR�.�TIEK— III"C III 1111ti III IIY fi Ilt„ r.,El-0 `;r;is f'T Fans Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 200.9 AMCA Statement Nortek Air Solutions LLC certifies that the HPF-Al00 fan wheel shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA licensed air and/or sound performance data has been modified for installation,appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but , is provided to aid in selection and applications of the product. Performance certified is for installation type ARe A: Free Inlet/Free Outlet Power[bhp]excludes drives AIR FWTRating DLL: Ver-1.6/May 2022 RIM1i0 01 Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 18 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR�.�TIEK- III"C III 1111ii III IIY fi Ilt„ r.,El-0 `;r;is f'T Fans Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 201.1 Configuration/Quantity 1. Function Exhaust Fan Cell Size 5.Height 6.Width 7.Depth 8.Overall Depth 2. Quantity 6 34 38 1 32 39.25 3. Array 2 Rows x 3 Cols 9. Elev./Temp. 0 ft/70.0°F 4. Construction PentaCube 10.Motor&Wheel Weight 196 lb 112.Redundant 0 11.Fan Cell Weight 365 Ib 113.Empty 0 14.Ship Loose Fan(Wheel, Motor and Mounting Base) 0 201.2 Options 1. Coplanar Insulation Standard Melamine 7. Cell Finish None 2. Extended Coplanar No 8. Insulation Retainer No 3. Back Draft Dampers FBD8 9. Inlet Attenuation None 4. Inlet Cone Type A100 Curved Cone 10.Blankoff Material 16Ga Galy Pre-Paint 5. Discharge Safety Guard No 11.Blankoff Finish Pre-Paint 6. Cell Material 1304 Stainless Steel 1112.Removal Rail IND 201.3 Fan Wheel 1. Wheel Type HPF-A100 1 3. Width 80 2. Diameter 120 1 4. Max RPM 3521 5. Wheel Finish ElectroFin E-Coat 201.4 Motor 1. Manufacturer Baldor 6. Efficiency 88.5 2. HP Each/Total 6/36 7. Service Factor 1.15 3. Poles/RPM 4-Pole/ 1,740 8. Shaft Isolation Ceramic Bearings 4. Frame/Casing 184T/TEAO 9. FLA Each/Total 7.5/45.0 Amps 5. Volts/Phase/Hz 460/3/60 10.Motor HP Safety Factor 3.0 % 201.5 Variable Frequency Drive 1. Quantity 10 113. Maximum Hertz 190.09 2. Voltage 460/3/60 114. Input Line Reactor IND 201.6 Control System 1. Redundant VFD No 15. Flow Monitoring None 2. Drive Standard 16. Fans to Monitor INone 3. Optimization Control No 4. Control Method By Others 201.7 Notes/Features 1. To view patents and other pending U.S. or Canadian applications visit www.nortekair.com/patents. 2. Cell velocity is greater than 750.00 ft/min. 3. Cone constant=2524, cone flow differential pressure= 9.43 in.H2O at 7750 CFM per fan. 4. The estimated VFD input watts are based on the motor and VFD efficiency at the selected load and RPM. 5. Fans balanced to a maximum allowable level of 0.022 inches per second peak. Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 19 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 ,ddF46T' 1''YEJR TIEK- 4 1)'T 7111�"I-)t Fans ......................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01-R2 7.8- 6.3- -40 6.o 5.2- 7�7 rd 4.3- f5 14- -20 7-7 r-7: —7 2.6 DESIGN I LK OR%MAL EXHAUST 6.0 "I 0 20,kC 0010 Airflow CFM li AMC'A Lioerser, for-%un,dard Air Ferfornizrce%,,lithout Appurterzinces tlAccessories). Power [bhp)excl udes drives 201.8 Operating Conditions Operating Condition Usage CFM SP(in.H2O) Cell Qty RPM Hz Fanwheel BHP Vel Watts FEG FEI N I Input Adj. On OffFail Each Total (ft/min) %O.P. DESIGN 1 146,500 1.29 2.20 6 0 0 2,529 87.2 5.38 32.30 1,094 28,172 FEG85 14% .94 NORMAL EXHAUST 39 111,550 1.02 1.06 6 0 0 979 33.8 .44 2.63 272 3,026 FEG85 2% 1.31 Date/Revision:2023-08-09/Rev. P1 106 IN Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 20 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 ,ddF46T' 1`YEJR TIEl(- 4 1 fT 7111�',I-)t Fans ......................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01-R2 Bare Fan Sound Power- with Coplanar Si,lencer- (dB re: 1OE-12 watts) I nlet Lvik 103, Lvi: 1,04 97 S3 '91 70- 60-1 5�10 100- 24 22 of 7 40 613.Hz 125 Hz 250 Hz 5�100 Hz 1 K Hz 2K Hz 4K Hz 8-K Hz Outlet- Lvek 99, Lvi: 101 201.9 Bare Fan Sound Power with Coplanar Silencer(dB re: I OE-12 watts) Operating Condition 63 125 250 500 1k 2k 4k 8k LwA Lw DESIGN Inlet 89 89 96 99 97 97 93 91 103 104 Outlet 91 89 91 94 97 92 87 78 99 101 NORMAL EXHAUST Inlet 69 81 73 67 68 65 61 58 73 82 Outlet 71 80 69 66 65 60 56 47 70 81 1 Date/Revision:2023-08-09/Rev. P1 106 IN Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 21 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I[I'°j' JR�.�TIEK— III"C III 1111ti III IIY fi Ilt„ r.,El-0 `;r;is f'T Fans Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 201.10 AMCA Statement Nortek Air Solutions LLC certifies that the HPF-A100 fan wheel shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA licensed air and/or sound performance data has been modified for installation,appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but , is provided to aid in selection and applications of the product. Performance certified is for installation type ARe A: Free Inlet/Free Outlet Power[bhp]excludes drives AIR FWTRating DLL: Ver-1.6/May 2022 RIM1i0 01 Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 22 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 w. ,.o q F-1 S �_ ��" �CD S F E INNA.I....pw l 0 V..., PROJECT CITY OF PEARLAND NATATORIUM RENOVATION QUOTE# 22-0168-005 UNIT TAG NAHU-01 R2 QUANTITY 1 Coils Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 23 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR�.�TIEK_ III"C III 1111ii III IIY fi E Ilt„ r.,El-0 `;r;is f'T f t;1' J­" Cons Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Sales Order#: -007 Unit Tag: NAHU-01_R3 t11 �Illlu f f 300.1 Coil Layout 1. Coil Hand Right 6. Rack Style None 2. Configuration Single 7. Rack Finish None 3. Connection Orientation Straight 8. Blankoff Material 16Ga Galy Pre-Paint 4. Connection Material Red Brass 9. Blankoff Finish Pre-Paint 5. Connection Type MPT 300.2 Construction 1. Quantity 3 8. Stand Height 11 in 14.Casing 116Ga Galy 2. Serpentine 1.5 Tube Detail-Primary Surface 15.Coating I ElectroFin E-Coat 3. Fin Height 39.000 in 9. Material Copper Fin Detail-Secondary Surface 4. Fin Length 112.000 in 10.0.D. x Wall 0.625 x 0.020 in 16.Material Aluminum 5. Rows 6 11.Spacing 1.500 x 1.299 in 17.Thickness 0.008 in 6. Fins per Inch 17 112.Internal Smooth Corrugated,Waffle with 7. Face Area 191.00 ft2 113.Return Bends 10.028 in 18.Configuration Straight Edge Single Bank, Right Hand, 3 per unit 5WC - 4 - 39 x 112 x 6 - 7 AL Supply/Return Connections Vent and Drain Quantity Type Pipe Size Material Type Vent Location Drain Location 2 MPT 3.0 in Red Brass 0.125 in FPT Return Connection Supply Connection 300.3 DESIGN Entering Leaving 1. Actual Airflow 10.Total Capacity 1,862.8 MBH 2. Standard Airflow 46,500 SCFM 11.Sensible Capacity 1,332.7 MBH 3. Elevation 12.Face Velocity 510.99 ft/min 4. Entering Air DB 80.9°F 13.Leaving Air DB 54.9°F 5. Entering Air WB 67.4°F 14.Leaving Air WB 54.4°F 6. Fluid Type Water 15.APD 0.59 in.H20 7. Entering Fluid Temp 45.0°F 16.Leaving Fluid Temp 54.3°F 8. Fluid Flow Rate 398.4 GPM 17.Fluid Velocity 3.78 ft/s 9. Fluid Fouling Internal 0.0000 18.Fluid Pressure Drop 8.73 ft.H20 Notes: 1. Certified in accordance with the AHRI Forced-Circulation Air-Cooling and Air-Heating Coils Certification Program which is based on AHRI Standard 410 within the Range of Standard Rating Conditions listed in Table 1 of the Standard. Certified units may be found in the AHRI Directory at www.ahridirectory.org. 300.4 Notes/Features 1. Manufacturer: Nortek Air Solutions, 5510 SW 29th Street, Oklahoma City, OK 73179 2. Top and bottom casing flange height is 1.000 in. 3. Coil to have corrosion resistant coating (ElectroFin E-Coat)with UV Topcoat. 4. Coils to be pressure tested at 315 PSI 5. Total operating weight is 2,438 lb. 6. Total fluid volume is 76.8 Gal. Date:2023-08-09 106 N Industrial Blvd.0karche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. DocuSign Envelope ID:41DDF136313-7ADO-41 131-B32F-OEBCA9573CB9 r.,El-0 `;r;is f YT f t;1' J­" Cons Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 301.1 Coil Layout 1. Coil Hand Right 6. Rack Style None 2. Configuration Single 7. Rack Finish None 3. Connection Orientation Straight 8. Blankoff Material 16Ga 316 SS 4. Connection Material Red Brass 9. Blankoff Finish Pre-Paint 5. Connection Type MPT 301.2 Construction 1. Quantity 3 8. Stand Height 11 in 14.Casing 116Ga 304 SS 2. Serpentine 1 Tube Detail-Primary Surface 15.Coating I ElectroFin E-Coat 3. Fin Height 39.000 in 9. Material Copper Fin Detail-Secondary Surface 4. Fin Length 112.000 in 10.0.D. x Wall 0.625 x 0.020 in 16.Material Aluminum 5. Rows 2 11.Spacing 1.500 x 1.299 in 17.Thickness 0.008 in 6. Fins per Inch 17 12.Internal Smooth Corrugated,Waffle with 7. Face Area 191.00 ft2 13.Return Bends 0.028 in 18.Configuration Straight Edge Single Bank, Right Hand, 3 per unit 5WC - 2 - 39 x 112 x 2 - 7 AL Supply/Return Connections Vent and Drain Quantity Type Pipe Size Material Type Vent Location Drain Location 2 MPT 2.5 in Red Brass 0.125 in FPT Return Connection Supply Connection 301.3 DESIGN Entering Leaving 1. Actual Airflow 2. Standard Airflow 46,500 SCFM 9. Sensible Capacity 2,388.1 MBH 3. Elevation 10.Face Velocity 510.99 ft/min 4. Entering Air DB 55.0°F 11.Leaving Air DB 102.4°F 5. Fluid Type Water 12.APD 0.15 in.H20 6. Entering Fluid Temp 180.0°F 13.Leaving Fluid Temp 1158.5°F 7. Fluid Flow Rate 227.0 GPM 14.Fluid Velocity 13.23 ft/s 8. Fluid Fouling Internal 0.0000 15.Fluid Pressure Drop 13.84 ft.H20 Notes: 1. Certified in accordance with the AHRI Forced-Circulation Air-Cooling and Air-Heating Coils Certification Program which is based on AHRI Standard 410 within the Range of Standard Rating Conditions listed in Table 1 of the Standard. Certified units may be found in the AHRI Directory at www.ahridirectory.org. 301.4 Notes/Features 1. Manufacturer: Nortek Air Solutions, 5510 SW 29th Street, Oklahoma City, OK 73179 2. Top and bottom casing flange height is 1.000 in. 3. Coil to have corrosion resistant coating (ElectroFin E-Coat)with UV Topcoat. 4. Coils to be pressure tested at 315 PSI 5. Total operating weight is 1,104 lb. 6. Total fluid volume is 28.4 Gal. Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.0karche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 25 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 w. ,.o q F-1 S �_ ��" �CD S F E INNA.I....pw l 0 V..., PROJECT CITY OF PEARLAND NATATORIUM RENOVATION QUOTE# 22-0168-005 UNIT TAG NAHU-01 R2 QUANTITY 1 Components Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 26 DocuSign Envelope ID:4DDFB63B-7ADO-41 B1-B32F-OEBCA9573CB9 �1' � I �.I VK- III' ui� �I°iI uim °iI ui m ur„ r.,(I? i.;r..is 1 ff l e P."� t Components Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 ' AR AR 500.1 Pre-Filter Size&Quantity 1. Loading Upstream Face Load 6. Bank Size 116.250 in W x 120.000 in H 2. Frame Material 316 Stainless Steel 7. Qty/set& Frame Size 1 (5)20 in x 24 in 3. Filter Clips By Others 8. Qty/set& Frame Size 2 (20)24 in x 24 in 4. Blankoff/Rack Material 16Ga 316 SS 9. Qty/set& Frame Size 3 5. Blankoff/Rack Finish None 10.Qty/set& Frame Size 4 500.2 Pre Filter 1. Filter Depth 2.000 in 4. Number of Sets 2. Efficiency 5. Max Face Velocity 481.03 ft/min at 46,500 SCFM 3. Manufacturer 6. Model 500.3 Pressure Gage Specifications-Gage 1 1. Manufacturer Dwyer Vent Valve, Exterior Measuring 2. Model/Range Magnehelic 2002 (0-2"w.c.) 3. Options Taps, Signal Flag 4. Quantity 1 500.4 Notes/Features 1. Filters and Clips provided by Others. Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 27 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR�.�TIEK- III"C III 1111ii III IIY fi Ilt„ r.,(I? i.;r;is 1 ff l e P;� t _' 7 Components Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 600.1 Opening Construction 1. Description Outside Air 14. Shape Rectangle 2. Max CFM 10,500 SCFM 15. Max APD 10.03 in.1-12O 3. Size 30 W x 42 H in 600.2 Damper Specifications 1. Manufacturer Ruskin 6. Jackshaft Yes 2. Model Ruskin CD 50 (Aluminum) 7. Max Face Velocity 1,200.00 ft/min 3. Size 30.000 in (Blade Direction)x 8. End Switches No 42.000 in 4. Blade Config Opposed 5. Blade Orientation Horizontal Notes: 1. Ordered with 1"frame flange 600.3 Damper Actuator 1. Location 3. Floor Mounted 2. Type 4. Furnished By Others 5. Mounted By Others 6. Wiring By Others 600.4 Notes/Features 1. Damper Actuators and mounting accessories furnished and mounted by Others at Left Hand location. 2. Damper Actuators wired by Others 601.1 Opening Construction 1. Description Outside Air 14. Shape Rectangle 2. Max CFM 36,000 SCFM 15. Max APD 10.04 in.1-12O 3. Size 90 W x 42 H in 601.2 Damper Specifications 1. Manufacturer Ruskin 6. Jackshaft Yes 2. Model Ruskin CD 50 (Aluminum) 7. Max Face Velocity 1,371.43 ft/min 3. Size 90.000 in (Blade Direction)x 8. End Switches No 42.000 in 4. Blade Config Opposed 5. Blade Orientation Horizontal Notes: 1. Ordered with 1"frame flange 601.3 Damper Actuator 1. Location 3. Floor Mounted 2. Type 4. Furnished By Others 5. Mounted By Others 6. Wiring By Others 601.4 Notes/Features 1. Damper Actuators and mounting accessories furnished and mounted by Others at Right Hand location. 2. Damper Actuators wired by Others Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 28 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR�.�TIEK- III"C III 1111ii III IIY fi Ilt„ r.,(I? i.;r;is 1 ff l e P;� t _' 7 Components Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 602.1 Opening Construction 1. Description Supply Air 4. Shape Rectangle 2. Max CFM 46,500 SCFM 5. Max APD 0.10 in.1-12O 3. Size 80 W x 80 H in 6. Max Velocity 1,047.00 ft/min 603.1 Opening Construction 1. Description Return Air 4. Shape Rectangle 2. Max CFM 46,500 SCFM 5. Max APD 0.00 in.1-12O 3. Size 121 W x 46.5 H in 6. Max Velocity 1,191.00 ft/min 604.1 Opening Construction 1. Description Exhaust Air 4. Shape Rectangle 2. Max CFM 46,500 SCFM 5. Max APD 0.29 in.1-12O 3. Size 60 W x 71 H in 6. Max Velocity 1,572.00 ft/min 605.1 Opening Construction 1. Description Return Air 14. Shape Rectangle 2. Max CFM 36,000 SCFM 15. Max APD 10.18 in.1-12O 3. Size 96 W x 48 H in 605.2 Damper Specifications 1. Manufacturer Ruskin 6. Jackshaft Yes 2. Model Ruskin CD 50 (Aluminum) 7. Max Face Velocity 1,125.00 ft/min 3. Size 96.000 in (Blade Direction)x 8. End Switches No 48.000 in 4. Blade Config Opposed 5. Blade Orientation Horizontal Notes: 1. Ordered with 1"frame flange 605.3 Damper Actuator 1. Location 3. Floor Mounted 2. Type 4. Furnished By Others 5. Mounted By Others 6. Wiring By Others 605.4 Notes/Features 1. Damper Actuators and mounting accessories furnished and mounted by Others at Right Hand location. 2. Damper Actuators wired by Others Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 29 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 w. ,.o q F-1 S �_ ��" �CD S F E INNA.I....pw l 0 V..., PROJECT CITY OF PEARLAND NATATORIUM RENOVATION QUOTE# 22-0168-005 UNIT TAG NAHU-01 R2 QUANTITY 1 Electrical Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 30 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 Electrical Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 700.1 Electrical Service Information 1. Volt/Phase/Hertz 460/3/60 113. Provides power to Exhaust Fan 2. MCA 146.9 1. For electrical loads see electrical drawings 700.2 Construction 1. Enclosure Type MSP Panel 4. Mounting Surface mount on unit 2. Type NEMA 4X Indoor/Outdoor 3. Size See electrical drawings 700.3 Options 1. Cooling Fan No 5. Floor Stand No 2. Filter Kit No 6. Control Transformer No 3. Keypad or Touch screen No 7. Window Kit No on Door 4. Power Transformer No 700.4 Notes/Features 1. MSP panel includes motor protection. MSP panel must be visible and within 50 feet from electrical disconnect. 701.1 Electrical Service Information 1. Volt/Phase/Hertz 460/3/60 113. Provides power to Supply Fan 2. MCA 160.1 1. For electrical loads see electrical drawings 701.2 Construction 1. Enclosure Type MSP Panel 4. Mounting Surface mount on unit 2. Type NEMA 4X Indoor/Outdoor 3. Size See electrical drawings 701.3 Options 1. Cooling Fan No 5. Floor Stand No 2. Filter Kit No 6. Control Transformer No 3. Keypad or Touch screen No 7. Window Kit No on Door 4. Power Transformer No 701.4 Notes/Features 1. MSP panel includes motor protection. MSP panel must be visible and within 50 feet from electrical disconnect. AR 702.1 Electrical Service Information 1. Volt/Phase/Hertz 120/1/60 112. Provides power to Switch/Outlet, Lighting 702.2 Switches/Outlets Name Box Section Type Mounted Illum. Switch Timer Cover GFCI MOCP Switch/Outlet E Endwall 2 Light Switch/ External Yes None No Yes 20.0 Amps 120V Outlet •Switch/Outlet is connected to service. Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.0karche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 31 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 Electrical Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 702.3 Lighting Types and Quantities (6) 15W LED Bulb Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 32 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR�.�T IEu t III"C Ili 11111I Ili IIiF III„ r.,(I? i.;r;is 1 ff l e P;, Electrical Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-005 Unit Tag: NAHU-01_R2 1 RIIIIIIII � � � OIIIIV q QA Opening 1 Damper Adutwo PQA Oponing Damp Tick r_ RA C wring U N t� . J �A Fttuurrrro�uishe Gmers I Admitta Foinniiu bed 9r,Mars ["I Aduakw Furnished By 01has AcAmtog Mounted IDV I rylws Actiatair MoLmleid iDuems Act Actktw Maumted ' mn E@-emtsimel'Som nits F1 trmiceG Serr lrt Fle trizal Sepowr Fmm er FiF"SiF Fammsem tFr(b kF Fmmwea 12FI V6011 FILA,:45 Flu;,Sly hmllf„^47 W :51 5VAkhJ DiLdet; I,,!� anmwval ouflel C FPF F emni 29 O drm I�mumil ru�ICti GGO Type 4 TYPO ; t5+l �LEmI4i�U °u�`, F IG L 2 lExha usQf L I(Is of y) mawlst Fes Sopoy Fain �(5)Fans (9)Fans Note:The FLA and MCA values shown are estimated,see the electrical schematics for the actual values. ......................................n:....2...............................................................................................................................................................................................................iaI......................................................................................................................................................................................................................................................................................................... Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 33 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 . , , Unit Design Revision History S0 Il LJ"F. C S PROJECT CITY OF PEARLAND NATATORIUM RENOVATION QUOTE# 22-0168-006 UNIT TAG NAHU-02 R2 QUANTITY 1 Date Rev Revision Description 2022-12-30 2 ALUMINUM CONSTRUCTION �..W' II II r. (Wdr'di', �'. ir�r� '"•-..r..,..r..�;��? I n I i i ..w I I I �I l� Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 34 _ Qo 0 c� z EF P SF MOP z a J O O� 99 — a - d G Z v ¢�¢ v non G — wb 3 0 - _ E E72 3�00 L — _ - Dom + - - _� w� 3�00 io �ro3 o000 T—T- ° ESE - - -- - - _ OL d£ — ................................... -- 0 E a _ zi v M 09 bl `a 4 i a a w Q S'8£ m M Q U m 0 m m Q m m C, EF OP SF MOP o 0 0 w` o60-9o-Cmz{pv-vuw AMA)m'm 0 o _ v Z a > Z a LEI Ld P .. c IJ; �C7tip q LL- U � y7 of g C10 LIE r � a LO n O rl b d L U f` k L p U M1I 9r, c E p o �rlf^r 3 a a o o c aL� � � m m W O va LL h ry d Oj 0 41q A y m m LL C Q 0 C W C 2M U) 0 60-80-£ZOZ :(PP-WW-AAAA) PaIuud 0 2 z K= - 9 - / LLJ g } \a ok 2 a _ m z 2 ? t y= g <2 :e k 3 : / \\ m. \® 2 a /> \ / §\ : \\k/ g 2 )\ �\ \ /Qj~ ) - -_ 3 } § / / � § ± CL a 3 f G 80-e0-EZOz }PmRR77% PG mNd 0 2 z K= - 9 - / LLJ g } \a ok 2 a _ m z A / »\ L « - / \\ / \- � \ / §\ g o ! s3 =2 \ \Qj® j w 9 .` & \^ � > © / / � § ± CL a 3 f G 80-e0-EZOz }PmRR77% PG mNd 0 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 A&r,,4W"1V IME.XR.............I............LEK,, AI F-1 S 0 Il LJ"F�CD S ............................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................. F E INNA I Fl 0 1 PROJECT CITY OF PEARLAND NATATORIUM RENOVATION QUOTE# 22-0168-006 UNIT TAG NAHU-02—R2 QUANTITY 1 Unit Design Options Date/Revision:2023-08-09/Rev. P1 106 IN Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 39 DocuSign Envelope ID:4DDFB63B-7ADO-41 B1-B32F-OEBCA9573CB9 �1' � I �.I VK- III' ul� �I°iI ulm °iI ui m ur„ r.,(I? i.;r;is 1 ff l e P. Unit Design Options Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 A4A4 iiu, . 100.1 Electrical 1. Short Circuit Current Rating(SCCR)@ 65 kA Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 40 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1` JR�.�T SUE l III"C III III mi III IIY fi Ilt„ r.,(I? i.;r;is 1 ft l e P. Unit Design Options Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 1 �Illu 101.1 Weights I Jobsite Elevation 1. Shipping Weight 115,372 lb 113. Elevation loft 2. Operating Weight 115,890 lb 101.2 Preparation for Shipment KNOCKDOWN CONSTRUCTION -Unit to be shipped assembled with minimum screws/bolts 1. Knockdown Construction from Factory. Unit disassembly and re-assembly by"OTHERS" in the Field. Unit to be caulked by"OTHERS" in the Field. 101.3 KID Field Opening Size 1.Height 2.Width 3.Depth in 1 m 102.1 Construction 1. Cabinet Construction ITF- Integrated Frame 16. Thermal Break Modified Thermal Break 2. Design Environment Indoor 17. Mounting Slab Mounted 3. Panel Depth 3 in 4. Caulk Type Standard 5. Model# 102.2 Cabinet Material 1. Exterior Material 0.063 Alum Pre-Paint 7. Blankoff Finish Pre-Paint(See Exceptions) 2. Interior Liner type(s) See Drawing 8. Internal Wall Material 116Ga Galy Pre-Paint 3. Exterior Paint Type Pre-Paint Insulation by liner type 4. Interior Paint Type Pre-Paint 9. Solid liner Polyurethane Foam (R24) 5. Paint Color Sandstone 6. 5000 Hr Salt Spray IND Exceptions: 1. Chilled Water Coil: blankoff material is 16Ga 316 SS 2. Hot Water Reheat Coil: blankoff material is 16Ga 316 SS 3. Filters: blankoff material is 16Ga 316 SS, blankoff finish is None 102.3 Base Construction 1. Base Structure Material Steel Tube 6. Base Structure Height See Drawing 2. Base Floor Material 0.100 Alum Treadplate Pre-Paint 7. Sub Floor Material 0.040 Alum Pre-Paint 3. Insulation Polyurethane Foam 8. Floor Coating None 4. Floor Drain None 9. Lifting Lugs Yes-Welded 5. Floor Options None 102.4 Box Dimensions Box X Y Z Shipping Weight Operating Weight A 65.500 in 110.000 in 119.500 in 4,246 lb 4,169 lb B 73.000 in 110.000 in 119.500 in 2,346 lb 2,346 lb C 39.000 in 110.000 in 119.500 in 2,328 lb 2,833 lb D 37.000 in 110.000 in 119.500 in 1,542 lb 1,731 lb E 65.500 in 1 110.000 in 119.500 in 4,361 lb 4,262 lb 102.5 Notes I Features 1. Box dimensions do not include lifting lugs, electrical panels, pipe connections, door handles, etc. 103.1 All Doors(including those associated with specific components) # I Box I Section I Type' I Width I Height I Hinge I Swing I Window I Interior I Exterior 1 1 A I FWT2 1 3"TBF 1 24 60 LH In 10 x 10 TB 10.063 Alum Pre-Paint 10.063 Alum Pre-Paint Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 41 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1` JR�.�T SUE l III"C III III mi III IIY fi Ilt„ r.,(I? i.;r;is 1 ft l e P. Unit Design Options Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 # Box Section Type' Width Height Hinge Swing Window Interior Exterior 2 B PL1 3"TBF 24 72 RH Out None 0.063 Alum Pre-Paint 0.063 Alum Pre-Paint 3 B PL2 3"TBF 24 72 RH Out None 0.063 Alum Pre-Paint 0.063 Alum Pre-Paint 4 C CW1 3"TBF 21 72 LH Out None 0.063 Alum Pre-Paint 0.063 Alum Pre-Paint 5 D HW1 3"TBF 21 72 LH Out None 0.063 Alum Pre-Paint 0.063 Alum Pre-Paint 161 E I FWT1 1 3"TBF 1 27 72 1 RH I In I 10 x 10 TB 10.063 Alum Pre-Paint 0.063 Alum Pre-Paint 103.2 Notes/Features 1. Door Types TBF=Thermal Break Factory 2. All doors insulated with Polyurethane Foam. P. Options: SP=Sensor Port, TO=Tool Operated Handle 1 �Illu 104.1 All Drains(including those associated with specific components) Box Section Type Conn(in) Hand Grating Material Pan Material C CW1 Drain Pan 1.50 Left None 16Ga 316 SS D HW1 Drain Pan 1.25 Left None 16Ga 316 SS 104.2 Notes/Features 1. Drain Constructions included: Triple Pitched 1 105.1 All Internal Walls(including those associated with specific components) Box Section Wall Name Depth Panel Mat. Liner Mat. Insulated B Mixing Plenum InternalWall 2 in Default 16Ga Galy Pre-Paint True Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 42 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR�.�TIEK— III"C III 11111i III IIY fi Ilt„ r.,(I? i.;r;is 1 ff l e P. Unit Design Options Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 106.1 DESIGN 106.1.1 Unassigned Tunnel Description APD(in.H2O) Supply Air Tunnel JPOA Opening-Damper(Outside Air) 0.03 Total Static Pressure: 0.03 106.1.2 SUPPLY AIR Tunnel Description APD(in.H2O) Return Air Tunnel Main RA Opening 1 (Return Air) 0.00 Supply Air Tunnel RA Opening 1 -Damper(Return Air) 0.15 Supply Air Tunnel OA Opening 1 -Damper(Outside Air) 0.03 Supply Air Tunnel 2" MERV 11 Filters(CLEAN) 0.26 Supply Air Tunnel 2" MERV 11 Filters(DIRTY) 0.49 Supply Air Tunnel Chilled Water Coil 0.68 Supply Air Tunnel Hot Water Reheat Coil 0.14 Supply Air Tunnel FANWALL 1 (Supply)33,500 SCFM @ 3.36 in.H2O 0.00 Supply Air Tunnel SA Opening 1 (Supply Air) 0.11 EXTERNAL STATIC PRESSURE (SUPPLY AIR) 1.50 Total Static Pressure: 3.36 106.1.3 Exhaust Tunnel Description APD(in.H2O) Purge Air Tunnel FANWALL 2(Exhaust)33,500 SCFM @ 1.31 in.H2O 0.00 Purge Air Tunnel EA Opening (Exhaust Air) 0.31 EXTERNAL STATIC PRESSURE (EXHAUST AIR) 1.00 Total Static Pressure: 1.31 Legend: ESP-External Static Pressure, OSA-Outside Air, EXH -Exhaust Air, RA-Return Air, SA-Supply Air 106.2 Notes/Legend 1. Summary report does not include static pressure of components supplied by others in the field unless otherwise noted. Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 43 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 w. ,.o q F-1 S �_ ��" �CD S F E INNA.I....pw l 0 V..., PROJECT CITY OF PEARLAND NATATORIUM RENOVATION QUOTE# 22-0168-006 UNIT TAG NAHU-02 R2 QUANTITY 1 Fans Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 44 DocuSign Envelope ID:4DDFB63B-7ADO-41 B1-B32F-OEBCA9573CB9 �1' � I �.I VK- III' ui� �I°iI uim °iI ui m ur„ r.,El-0 `;r,is f/T f t;P:, Fans Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 200.1 Configuration/Quantity 1. Function Supply Fan Cell Size 5.Height 6.Width 7.Depth 8.Overall Depth 2. Quantity 6 34 40 1 28 35.25 3. Array 3 Rows x 2 Cols 9. Elev./Temp. 0 ft/52.0°F 4. Construction PentaCube 10.Motor&Wheel Weight 200 lb 112.Redundant 0 11.Fan Cell Weight 361 Ib 113.Empty 0 14.Ship Loose Fan(Wheel, Motor and Mounting Base) 0 200.2 Options 1. Coplanar Insulation Standard Melamine 7. Cell Finish None 2. Extended Coplanar No 8. Insulation Retainer No 3. Back Draft Dampers FBD8 9. Inlet Attenuation None 4. Inlet Cone Type A100 Curved Cone 10.Blankoff Material 16Ga Galy Pre-Paint 5. Discharge Safety Guard No 11.Blankoff Finish Pre-Paint 6. Cell Material 1304 Stainless Steel 1112.Removal Rail IYes 200.3 Fan Wheel 1. Wheel Type HPF-A100 1 3. Width 90 2. Diameter 120 1 4. Max RPM 3521 5. Wheel Finish ElectroFin E-Coat 200.4 Motor 1. Manufacturer Baldor 6. Efficiency 90.2 2. HP Each/Total 5/30 7. Service Factor 1.15 3. Poles/RPM 4-Pole/ 1,750 8. Shaft Isolation Ceramic Bearings 4. Frame/Casing 184T/TEAO 9. FLA Each/Total 6.5/39.0 Amps 5. Volts/Phase/Hz 460/3/60 10.Motor HP Safety Factor 3.0 % 200.5 Variable Frequency Drive 1. Quantity 10 113. Maximum Hertz 173.10 2. Voltage 460/3/60 114. Input Line Reactor IND 200.6 Control System 1. Redundant VFD No 15. Flow Monitoring None 2. Drive Standard 16. Fans to Monitor INone 3. Optimization Control No 4. Control Method By Others 200.7 Notes/Features 1. To view patents and other pending U.S. or Canadian applications visit www.nortekair.com/patents. 2. Cell velocity is greater than 750.00 ft/min. 3. Cone constant=2524, cone flow differential pressure= 6.04 in.H2O at 6204 CFM per fan. 4. The estimated VFD input watts are based on the motor and VFD efficiency at the selected load and RPM. 5. Fans balanced to a maximum allowable level of 0.022 inches per second peak. Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 45 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR�.�T IEu III,C III 1111ii III IIY fi Ilt„ r.,El-0 `;r;is f'T Fans Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 5. 5. � 55 _ 4.5 '"'s 3.3 CM ESI(7 rj 20 3. ' ESI 3h1�w>'w�,,IFeited 15 T �4 T 9 10 1." 5 ppm, 0.0 a 1o'kpfu 210,100 ' p'0010 40,CueO 5 ro �r� Airflow cj'F M �i ..........�� Failed Farr AM4 A Licerser, for and ar Air Perfornizrce%1,1ithouutAppuarterzrces tlAccessories;1. Ferf�ur nr�r�e�e r tifie is fc�ii irus�M Il�tui�y :A:Firee Ilinll wear F iree O�rtiel: Power[bhp)excl udes drives 200.8 Operating Conditions Operating Condition Usage CFM SP(in.H2O) Cell Qty RPM Hz Fanwheel BHP Vel. Watts FEG FEI N I Input Adj. On Off Fail Each Total (ft/min) %O.P. DESIGN 1 133,500 3.36 3.78 6 0 0 2,060 70.6 4.59 27.55 744 23,743 FEG851% 1.29 DESIGN w/Failed 1 131,018 2.88 3.41 5 0 1 2,132 73.1 4.84 24.22 827 20,849 FEG85 3% 1.25 Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 46 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I[I'°j' JR�.�TIEK— III"C III 1111ti III IIY fi Ilt„ r.,El-0 `;r;is f'T Fans Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 200.9 AMCA Statement Nortek Air Solutions LLC certifies that the HPF-Al00 fan wheel shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA licensed air and/or sound performance data has been modified for installation,appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but , is provided to aid in selection and applications of the product. Performance certified is for installation type ARe A: Free Inlet/Free Outlet Power[bhp]excludes drives AIR FWTRating DLL: Ver-1.6/May 2022 RIM1i0 01 Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 47 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR�.�TIEK- III"C III 1111ii III IIY fi Ilt„ r.,El-0 `;r;is f'T Fans Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 201.1 Configuration/Quantity 1. Function Exhaust Fan Cell Size 5.Height 6.Width 7.Depth 8.Overall Depth 2. Quantity 6 30 32 1 26 33.25 3. Array 2 Rows x 3 Cols 9. Elev./Temp. 0 ft/70.0°F 4. Construction PentaCube 10.Motor&Wheel Weight 161 lb 112.Redundant 0 11.Fan Cell Weight 297 Ib 113.Empty 0 14.Ship Loose Fan(Wheel, Motor and Mounting Base) 0 201.2 Options 1. Coplanar Insulation Standard Melamine 7. Cell Finish None 2. Extended Coplanar No 8. Insulation Retainer No 3. Back Draft Dampers FBD6 9. Inlet Attenuation None 4. Inlet Cone Type A100 Curved Cone 10.Blankoff Material 16Ga Galy Pre-Paint 5. Discharge Safety Guard No 11.Blankoff Finish Pre-Paint 6. Cell Material 1304 Stainless Steel 1112.Removal Rail IND 201.3 Fan Wheel 1. Wheel Type HPF-A100 1 3. Width 105 2. Diameter 116 4. Max RPM 3930 5. Wheel Finish ElectroFin E-Coat 201.4 Motor 1. Manufacturer Baldor 6. Efficiency 86.5 2. HP Each/Total 4/24 7. Service Factor 1.15 3. Poles/RPM 4-Pole/ 1,740 8. Shaft Isolation Ceramic Bearings 4. Frame/Casing 182T/TEAO 9. FLA Each/Total 5/30.0 Amps 5. Volts/Phase/Hz 460/3/60 10.Motor HP Safety Factor 3.0 % 201.5 Variable Frequency Drive 1. Quantity 10 113. Maximum Hertz 193.79 2. Voltage 460/3/60 114. Input Line Reactor IND 201.6 Control System 1. Redundant VFD No 15. Flow Monitoring None 2. Drive Standard 16. Fans to Monitor INone 3. Optimization Control No 4. Control Method By Others 201.7 Notes/Features 1. To view patents and other pending U.S. or Canadian applications visit www.nortekair.com/patents. 2. Cell velocity is greater than 750.00 ft/min. 3. Cone constant= 1671, cone flow differential pressure= 11.16 in.1-12O at 5583 CFM per fan. 4. The estimated VFD input watts are based on the motor and VFD efficiency at the selected load and RPM. 5. Fans balanced to a maximum allowable level of 0.022 inches per second peak. Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 48 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR.:T IEu III"C II III mI II IliO Ilt„ r.,El-0 `;r;is f'T Fans .................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 .?. 5.4 25 4.D 3 v*, fy, . y "q 3.: . 5 7 ESIG'N 0 � 'E4f3av;)'Fai14 1fI x1 O P PSI AL EXHAUST '" 5 0.7 0 pfr��u. 0.0 5 15,00fp 2"'o,000 300,000 ro �r� Airflow cj'FM �i ..........�� Failed Farr Al l A Licerser, for-%ua;n5 ar Air Perfornizrce%1,/ithouktAppuarterarces (Accessories;). Ferf�urnr�ar��e��ertifie� isfc��iilml �Mll�t�ul�y�e:,A:Freelllnllwa�rFreeO�rtiel�: Power[bhp)excl udes drives 201.8 Operating Conditions Operating Condition Usage CFM SP(in.H2O) Cell Qty RPM Hz Fanwheel BHP Vel. Watts FEG FEI N I Input I Adj. On Off Fail Each I Total (ft/min) %O.P. DESIGN 1 133,500 1.31 2.38 6 0 0 2,682 92.5 3.72 22.30 1,104 19,871 FEG8010% 1.03 DESIGN w/Failed 1 27,812 .90 1.96 5 0 1 2,620 90.3 3.30 16.51 1,100 14,725 FEG80 13% .99 NORMAL EXHAUST 39 111,550 1.04 1.11 6 0 0 1,248 43 .47 2.83 381 2,971 FEG80 0% 1.38 Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 49 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 ,ddF46T' 1''YEJR T SUE l(- 4 1)'T 7111�"I-)t Fans ......................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................................... Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02—R2 Bare Fan Sound Power- with Coplanar Si,lencer- (dB re: 1OE-12 watts) 110 I rtlet LviA:K Lve: 102 70- 610 � 100- 64 � 1 40 613.H'z 125 H'z 250 H'z 5�100 H'z 1 K H'z 2K H'z 4K Hz 8-K H'z Outlet- Lvik K Lo;:99 201.9 Bare Fan Sound Power with Coplanar Silencer(dB re: I OE-12 watts) Operating Condition 63 125 250 500 1k 2k 4k 8k LwA Lw DESIGN Inlet 88 82 92 101 89 88 89 85 98 102 Outlet 91 87 89 93 90 86 84 74 94 98 DESIGN w/Failed Inlet 87 81 91 99 88 87 88 84 97 101 Outlet 90 85 88 92 88 85 83 74 93 97 1 NORMAL EXHAUST Inlet 1 68 77 80 1 7 70 1 69 64 62 76 8 Outlet 1 73 80 80 1 741 83 67 1 64 59 51 74 8-4 Date/Revision:2023-08-09/Rev. P1 106 IN Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 50 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I[I'°j' JR�.�TIEK— III"C III 1111ti III IIY fi Ilt„ r.,El-0 `;r;is f'T Fans Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 201.10 AMCA Statement Nortek Air Solutions LLC certifies that the HPF-A100 fan wheel shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 211 and AMCA Publication 311 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA licensed air and/or sound performance data has been modified for installation,appurtenances or accessories, etc. not included in the certified data. The modified performance is not AMCA licensed but , is provided to aid in selection and applications of the product. Performance certified is for installation type ARe A: Free Inlet/Free Outlet Power[bhp]excludes drives AIR FWTRating DLL: Ver-1.6/May 2022 RIM1i0 01 Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 51 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 w. ,.o q F-1 S �_ ��" �CD S F E INNA.I....pw l 0 V..., PROJECT CITY OF PEARLAND NATATORIUM RENOVATION QUOTE# 22-0168-006 UNIT TAG NAHU-02 R2 QUANTITY 1 Coils Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 52 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR�.�TIEK_ III"C III 1111ii III IIY fi E Ilt„ r.,El-0 `;r;is f'T f t;1' J­" Cons Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Sales Order#: -006 Unit Tag: NAHU-02_R2 t 1 1 m u u N r 300.1 Coil Layout 1. Coil Hand Left 6. Rack Style None 2. Configuration Single 7. Rack Finish None 3. Connection Orientation Straight 8. Blankoff Material 16Ga Galy Pre-Paint 4. Connection Material Red Brass 9. Blankoff Finish Pre-Paint 5. Connection Type MPT 300.2 Construction 1. Quantity 2 8. Stand Height 11 in 14.Casing 114Ga Galy 2. Serpentine 1.5 Tube Detail-Primary Surface 15.Coating I ElectroFin E-Coat 3. Fin Height 51.000 in 9. Material Copper Fin Detail-Secondary Surface 4. Fin Length 94.000 in 10.0.D. x Wall 0.625 x 0.020 in 16.Material Aluminum 5. Rows 6 11.Spacing 1.500 x 1.299 in 17.Thickness 0.008 in 6. Fins per Inch 18 12.Internal Smooth Corrugated,Waffle with 7. Face Area 66.58 ft2 13.Return Bends 0.028 in 18.Configuration Straight Edge Single Bank, Left Hand, 2 per unit 5WC - 4 - 51 x 94 x 6 - 8 AL Supply/Return Connections Vent and Drain Quantity Type Pipe Size Material Type Vent Location Drain Location 2 MPT 3.0 in Red Brass 0.125 in FPT Return Connection Supply Connection 300.3 DESIGN Entering Leaving 1. Actual Airflow 10.Total Capacity 1,477.9 MBH 2. Standard Airflow 33,500 SCFM 11.Sensible Capacity 1,014.9 MBH 3. Elevation 12.Face Velocity 503.13 ft/min 4. Entering Air DB 82.0°F 13.Leaving Air DB 54.5°F 5. Entering Air WB 68.4°F 14.Leaving Air WB 54.2°F 6. Fluid Type Water 15.APD 0.68 in.H20 7. Entering Fluid Temp 45.0°F 16.Leaving Fluid Temp 54.3°F 8. Fluid Flow Rate 315.7 GPM 17.Fluid Velocity 3.43 ft/s 9. Fluid Fouling Internal 0.0000 18.Fluid Pressure Drop 8.54 ft.H20 Notes: 1. Certified in accordance with the AHRI Forced-Circulation Air-Cooling and Air-Heating Coils Certification Program which is based on AHRI Standard 410 within the Range of Standard Rating Conditions listed in Table 1 of the Standard. Certified units may be found in the AHRI Directory at www.ahridirectory.org. 300.4 Notes/Features 1. Manufacturer: Nortek Air Solutions, 5510 SW 29th Street, Oklahoma City, OK 73179 2. Top and bottom casing flange height is 1.000 in. 3. Coil to have corrosion resistant coating (ElectroFin E-Coat)with UV Topcoat. 4. Coils to be pressure tested at 315 PSI 5. Total operating weight is 1,858 lb. 6. Total fluid volume is 57.6 Gal. Date:2023-08-09 106 N Industrial Blvd.0karche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. DocuSign Envelope ID:41DDF136313-7ADO-41 131-B32F-OEBCA9573CB9 r.,El-0 `;r;is f YT f t;1' J­" Cons Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 t 1 �Illu p l 301.1 Coil Layout 1. Coil Hand Left 6. Rack Style None 2. Configuration Single 7. Rack Finish None 3. Connection Orientation Straight 8. Blankoff Material 16Ga 316 SS 4. Connection Material Red Brass 9. Blankoff Finish Pre-Paint 5. Connection Type MPT 301.2 Construction 1. Quantity 2 8. Stand Height 11 in 14.Casing 116Ga 304 SS 2. Serpentine 1 Tube Detail-Primary Surface 15.Coating I ElectroFin E-Coat 3. Fin Height 51.000 in 9. Material Copper Fin Detail-Secondary Surface 4. Fin Length 94.000 in 10.0.D. x Wall 0.625 x 0.020 in 16.Material Aluminum 5. Rows 2 11.Spacing 1.500 x 1.299 in 17.Thickness 0.008 in 6. Fins per Inch 17 12.Internal Smooth Corrugated,Waffle with 7. Face Area 66.58 ft2 13.Return Bends 0.028 in 18.Configuration Straight Edge Single Bank, Left Hand, 2 per unit 5WC - 2 - 51 x 94 x 2 - 7 AL Supply/Return Connections Vent and Drain Quantity Type Pipe Size Material Type Vent Location Drain Location 2 MPT 2.5 in Red Brass 0.125 in FPT Return Connection Supply Connection 301.3 DESIGN Entering Leaving 1. Actual Airflow 2. Standard Airflow 33,500 SCFM 9. Sensible Capacity 1,734.3 MBH 3. Elevation 10.Face Velocity 503.13 ft/min 4. Entering Air DB 55.0°F 11.Leaving Air DB 102.8°F 5. Fluid Type Water 12.APD 0.14 in.H20 6. Entering Fluid Temp 180.0°F 13.Leaving Fluid Temp 1160.0°F 7. Fluid Flow Rate 173.7 GPM 14.Fluid Velocity 12.89 ft/s 8. Fluid Fouling Internal 0.0000 15.Fluid Pressure Drop 14.21 ft.H20 Notes: 1. Certified in accordance with the AHRI Forced-Circulation Air-Cooling and Air-Heating Coils Certification Program which is based on AHRI Standard 410 within the Range of Standard Rating Conditions listed in Table 1 of the Standard. Certified units may be found in the AHRI Directory at www.ahridirectory.org. 301.4 Notes/Features 1. Manufacturer: Nortek Air Solutions, 5510 SW 29th Street, Oklahoma City, OK 73179 2. Top and bottom casing flange height is 1.000 in. 3. Coil to have corrosion resistant coating (ElectroFin E-Coat)with UV Topcoat. 4. Coils to be pressure tested at 315 PSI 5. Total operating weight is 784 lb. 6. Total fluid volume is 21.6 Gal. Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.0karche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 54 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 w. ,.o q F-1 S �_ ��" �CD S F E INNA.I....pw l 0 V..., PROJECT CITY OF PEARLAND NATATORIUM RENOVATION QUOTE# 22-0168-006 UNIT TAG NAHU-02 R2 QUANTITY 1 Components Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 55 DocuSign Envelope ID:4DDFB63B-7ADO-41 B1-B32F-OEBCA9573CB9 �1' � I �.I VK- III' ui� �I°iI uim °iI ui m ur„ r.,(I? i.;r..is 1 ff l e P."� t Components Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 ' AR AR 500.1 Pre-Filter Size&Quantity 1. Loading Upstream Face Load 6. Bank Size 96.188 in W x 104.000 in H 2. Frame Material 316 Stainless Steel 7. Qty/set& Frame Size 1 (4)24 in x 24 in 3. Filter Clips By Others 8. Qty/set& Frame Size 2 (16)20 in x 24 in 4. Blankoff/Rack Material 16Ga 316 SS 9. Qty/set& Frame Size 3 5. Blankoff/Rack Finish None 10.Qty/set& Frame Size 4 500.2 Pre Filter 1. Filter Depth 2.000 in 4. Number of Sets 2. Efficiency 5. Max Face Velocity 483.17 ft/min at 33,500 SCFM 3. Manufacturer 6. Model 500.3 Pressure Gage Specifications-Gage 1 1. Manufacturer Dwyer Vent Valve, Exterior Measuring 2. Model/Range Magnehelic 2002 (0-2"w.c.) 3. Options Taps, Signal Flag 4. Quantity 1 500.4 Notes/Features 1. Filters and Clips provided by Others. Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 56 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR�.�TIEK- III"C III 1111ii III IIY fi Ilt„ r.,(I? i.;r;is 1 ff l e P;� t _' 7 Components Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 600.1 Opening Construction 1. Description Outside Air 14. Shape Rectangle 2. Max CFM 10,500 SCFM 15. Max APD 10.03 in.1-12O 3. Size 32 W x 36 H in 600.2 Damper Specifications 1. Manufacturer Ruskin 6. Jackshaft Yes 2. Model Ruskin CD 50 (Aluminum) 7. Max Face Velocity 1,312.50 ft/min 3. Size 32.000 in (Blade Direction)x 8. End Switches No 36.000 in 4. Blade Config Opposed 5. Blade Orientation Horizontal Notes: 1. Ordered with 1"frame flange 600.3 Damper Actuator 1. Location 3. Floor Mounted 2. Type 4. Furnished By Others 5. Mounted By Others 6. Wiring By Others 600.4 Notes/Features 1. Damper Actuators and mounting accessories furnished and mounted by Others at Right Hand location. 2. Damper Actuators wired by Others 601.1 Opening Construction 1. Description Outside Air 14. Shape Rectangle 2. Max CFM 23,000 SCFM 15. Max APD 10.03 in.1-12O 3. Size 70 W x 36 H in 601.2 Damper Specifications 1. Manufacturer Ruskin 6. Jackshaft Yes 2. Model Ruskin CD 50 (Aluminum) 7. Max Face Velocity 1,314.29 ft/min 3. Size 70.000 in (Blade Direction)x 8. End Switches No 36.000 in 4. Blade Config Opposed 5. Blade Orientation Horizontal Notes: 1. Ordered with 1"frame flange 601.3 Damper Actuator 1. Location 3. Floor Mounted 2. Type 4. Furnished By Others 5. Mounted By Others 6. Wiring By Others 601.4 Notes/Features 1. Damper Actuators and mounting accessories furnished and mounted by Others at Left Hand location. 2. Damper Actuators wired by Others Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 57 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR�.�TIEK- III"C III 1111ii III IIY fi Ilt„ r.,(I? i.;r;is 1 ff l e P;� t _' 7 Components Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 602.1 Opening Construction 1. Description Supply Air 4. Shape Rectangle 2. Max CFM 33,500 SCFM 5. Max APD 0.11 in.1-12O 3. Size 66 W x 66 H in 6. Max Velocity 1,108.00 ft/min 603.1 Opening Construction 1. Description Return Air 4. Shape Rectangle 2. Max CFM 33,500 SCFM 5. Max APD 0.00 in.1-12O 3. Size 103 W x 38.5 H in 6. Max Velocity 1,217.00 ft/min 604.1 Opening Construction 1. Description Exhaust Air 4. Shape Rectangle 2. Max CFM 33,500 SCFM 5. Max APD 0.31 in.1-12O 3. Size 48 W x 62 H in 6. Max Velocity 1,621.00 ft/min 605.1 Opening Construction 1. Description Return Air 14. Shape Rectangle 2. Max CFM 23,500 SCFM 15. Max APD 10.15 in.1-12O 3. Size 90 W x 36 H in 605.2 Damper Specifications 1. Manufacturer Ruskin 6. Jackshaft Yes 2. Model Ruskin CD 50 (Aluminum) 7. Max Face Velocity 1,044.44 ft/min 3. Size 90.000 in (Blade Direction)x 8. End Switches No 36.000 in 4. Blade Config Opposed 5. Blade Orientation Horizontal Notes: 1. Ordered with 1"frame flange 605.3 Damper Actuator 1. Location 3. Floor Mounted 2. Type 4. Furnished By Others 5. Mounted By Others 6. Wiring By Others 605.4 Notes/Features 1. Damper Actuators and mounting accessories furnished and mounted by Others at Left Hand location. 2. Damper Actuators wired by Others Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 58 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 w. ,.o q F-1 S �_ ��" �CD S F E INNA.I....pw l 0 V..., PROJECT CITY OF PEARLAND NATATORIUM RENOVATION QUOTE# 22-0168-006 UNIT TAG NAHU-02 R2 QUANTITY 1 Electrical Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 59 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 Electrical Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 AR AR , 700.1 Electrical Service Information 1. Volt/Phase/Hertz 460/3/60 113. Provides power to Exhaust Fan 2. MCA 131.3 1. For electrical loads see electrical drawings 700.2 Construction 1. Enclosure Type MSP Panel 4. Mounting Surface mount on unit 2. Type NEMA 4X Indoor/Outdoor 3. Size See electrical drawings 700.3 Options 1. Cooling Fan No 5. Floor Stand No 2. Filter Kit No 6. Control Transformer No 3. Keypad or Touch screen No 7. Window Kit No on Door 4. Power Transformer No 700.4 Notes/Features 1. MSP panel includes motor protection. MSP panel must be visible and within 50 feet from electrical disconnect. 701.1 Electrical Service Information 1. Volt/Phase/Hertz 460/3/60 113. Provides power to Supply Fan 2. MCA 140.6 1. For electrical loads see electrical drawings 701.2 Construction 1. Enclosure Type MSP Panel 4. Mounting Surface mount on unit 2. Type NEMA 4X Indoor/Outdoor 3. Size See electrical drawings 701.3 Options 1. Cooling Fan No 5. Floor Stand No 2. Filter Kit No 6. Control Transformer No 3. Keypad or Touch screen No 7. Window Kit No on Door 4. Power Transformer No 701.4 Notes/Features 1. MSP panel includes motor protection. MSP panel must be visible and within 50 feet from electrical disconnect. AR 702.1 Electrical Service Information 1. Volt/Phase/Hertz 120/1/60 112. Provides power to Switch/Outlet, Lighting 702.2 Switches/Outlets Name Box Section Type Mounted Illum. Switch Timer Cover GFCI MOCP Switch/Outlet E FWT1 Light Switch/ External Yes None No Yes 20.0 Amps 120V Outlet •Switch/Outlet is connected to service. Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 60 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 Electrical Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 702.3 Lighting Types and Quantities (6) 15W LED Bulb Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 61 DocuSign Envelope ID:4DDFB63B-7ADO-41 131-B32F-OEBCA9573CB9 , 6 ',I1'' JR�.�T IEu t III"C Ili 11111I Ili IIY fi III„ r.,(I? i.;r;is 1 ff l e P;, Electrical Project Name: CITY OF PEARLAND NATATORIUM RENOVATION Quote#: 22-0168-006 Unit Tag: NAHU-02_R2 1 RIIIIIIII � � � OIIIIV q QA Opening 1 Damper Adutwo PQA Oponing Dam pow Tiak r_ RA C wring U N t� . J �A Fttuurrrro�uishe Gmers I Admitta Foinniiu bed 9r,Mars ["I Aduakw Furnished By 01has AcAmtog Moue IFV I rylws Actiatair MoLmleid items Act Actktw Maumted ' mn E@-emtrimel Som nits Fle,trmicam Serr lrt Fle trizal Sepowre Fu rarer 4,151FaW& Fawamsm tFr(b kF Fmmwea 12NV601 FILA,:30 F k 39 M,'A 32 W :4 5VAkhJ DiLdet; I,,!� anmwvrl ouflel C GPYF Feirm 200 mum 2160,� ru 801 C "'h i 4 24'W .SD Type 0, TYPO t5+l �LEmI4i�U °u�`, F IG L 2 IExha usQf SA Ak L l(duff y) mawlst Fes Swoo^t Fain 5)Fans I5)Fans Note:The FLA and MCA values shown are estimated,see the electrical schematics for the actual values. ......................................n:....2...............................................................................................................................................................................................................iaI......................................................................................................................................................................................................................................................................................................... Date/Revision:2023-08-09/Rev.P1 106 N Industrial Blvd.Okarche,Ok 73762 Design Assistant Unit Design Revision 2 (405)817-9700 FAX(405)263-4980 9.0.3/2.0.0.2 This Document is confidential, copyrighted and property of Nortek Air Solutions LLC. 62