Loading...
Ord. 0867-1 06-26-00ORDINANCE NO. 867-1 AN ORDINANCE OF THE CITY COUNCIL OF THE CITY OF PEARLAND, TEXAS, AMENDING SECTION 9.153, ADOPTED, OF ARTICLE VII, ELECTRICAL CODE, OF CHAPTER 9, ELECTRICITY, OF THE CITY OF PEARLAND CODE OF ORDINANCES, AS IT MAY HAVE BEEN, FROM TIME TO TIME, AMENDED, BY ADDING A NEW SUBSECTION TO ALLOW THE USE OF MODULAR OR MANUFACTURED LIGHTING SYSTEMS FOR LIMITED PURPOSES; PROVIDING A PENALTY FOR VIOLATION; HAVING A SAVINGS CLAUSE, A SEVERABILITY CLAUSE, AND A REPEALER CLAUSE; PROVIDING FOR CODIFICATION, PUBLICATION AND AN EFFECTIVE DATE. BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF PEARLAND, TEXAS: Section 1. That Section 9.153, Adopted, of Article VII, Electrical Code, of Chapter 9, Electricity, of the City of Pearland Code of Ordinances, is hereby amended to ADD subsection (c) to read as follows: "Section 9.153. Adopted. (c) Notwithstanding any contrary provisions in the 1996 Edition of the National Electrical Code, modular or manufactured wiring systems which are UL approved may be used for lighting purposes only." Section 2. Penalty. Any person who shall violate the provisions of this section shall be deemed guilty of a misdemeanor and shall, upon conviction by a court of competent jurisdiction, be punished by a fine in any sum not exceeding Two Hundred Dollars ($200.00). Section 3. Savings. All rights and remedies which have accrued in favor of the City under this Ordinance and amendments thereto shall be and are preserved for the benefit of the City. 1 ORDINANCE NO. 867-1 Section 4. Severability. If any section, subsection, sentence, clause, phrase or portion of this Ordinance is for any reason held invalid, unconstitutional or otherwise unenforceable by any court of competent jurisdiction, such portion shall be deemed a separate, distinct, and independent provision and such holding shall not affect the validity of the remaining portions thereof. Section 5. Repealer. All ordinances and parts of ordinances in conflict herewith are hereby repealed but only to the extent of such conflict. Section 6. Codification. It is the intent of the City Council of the City of Pearland, Texas, that the provisions of this Ordinance shall be codified in the City's official Code of Ordinances as provided hereinabove. Section 7. Publication and Effective Date. The City Secretary shall cause this Ordinance, or its caption and penalty, to be published in the official newspaper of the City of Pearland, upon passage of such Ordinance. The Ordinance shall then become effective ten (10) days from and after its publication, or the publication of its caption and penalty, in the official City newspaper. PASSED and APPROVED ON FIRST READING this the 12TH day of June , A. D., 2000. eTh. TOM REID MAYOR 2 ORDINANCE NO. 867-1 ATTEST: PASSED and APPROVED ON SECOND AND FINAL READING this the 26th day of June , A. D., 2000. ATTEST: UNG TY SE ETARY APPROVED AS TO FORM: erlIA- DARRIN M. COKER CITY ATTORNEY 3 04-2 TOM REID MAYOR VOTING RECORD (SECOND AND FINAL READING JUNE 26, 2000) Voting "Aye" - Councilmembers Beckman, Owens, Seeger, Marcott, and Wilkins. Voting "No" - None. Motion passes 5 to 0. PUBLICATION DATE: JUNE 28, 2000 EFFECTIVE DATE: JULY 8, 2000 PUBLISHED AS REQUIRED BY SECTION 3.10 OF THE CHARTER OF THE CITY OF PEARLAND, TEXAS CASCO CORPORATION o1 CASCO Ltd. City of Pearland Texas 3519 Liberty Drive Pearland, Texas 77581 Attn: Mona Phipps Office Manager, Permit Department Re: The Home Depot - Pearland, Texas Manufactured Wiring System Dear Ms. Phipps: Via: Overnight Mail April 13, 2000 Recently it has come to our atte tion that the City of Pearland is requesting a letter be provided describing why wishes to use a manufactured wi ino system for the HID lighting systems in their For this project Home Depot has selected a manufactured wiring system supplied through Addison -Parrish for Cooper Lighting. These types of systems have been adopted nationally by Home Depot in all areas of this country. Following are a few reasons The Home Depot prefers these types of systems: 1. Manufactured wiring systems are recognized by Article 604 of the National Electrical Code for this application. 2. The manufactured wiring system carries a UL label. 3. The manufactured wiring system uses #12 copper conductors appropriate for connection to a 20A circuit breaker. 4. Installation of system requires fewer man-hours to install versus a hard wired system. Thus allowing a shorter construction schedule and less chance for human error in wiring. 5. Provides flexibility for location of light fixtures, which generally are centered in aisles. 6. Allows fixtures to be easily relocated in the event the store revises the location of their racking layouts in order to better merchandise their stores to serve the surrounding community. Attached is a copy of catalog cut sheets of the components that we are proposing to use for this project if approved by the City of Pearland. V:\THDSW\599519\City of Pearland - Variance - 041300.doc 10877 Watson Road • St. Louis, Missouri 63127 • (314) 821-1100 FAX (314) 821-4162 IIC CASCO CORPORATION of CASCO Ltd. The Home Depot Pearland, Texas Page Two Time has become the essence. Permits for this project have been issued and construction is underway. In order to avoid delaying construction please advise us as soon as possible if this system meets with your approval and/or any additional steps required to receive approval. /mrb Enclosure: Cordially, ?.45rkez Patrick Burke Project Manager One (1) set of Electrical Cut Sheets (7 pages) One (1) Check in the amount of $100.00 for Variance cc: Ray Parker — THD, TX Connie Norton (Cooper) RLQ, PJH, PDB JCA/File 599519 V:\THDSW\599519\City of Pearland - Variance - 041300.doc 10877 Watson Road • St. Louis, Missouri 63127 • (314) 821-1100 • FAX (314) 821-4162 ec+ 319 Received: 4/13/00 9:24AM; 7704571665 -> CASCO CORP; Page 2 APR-13 00 10:21 FROM:ADDISON PARRISH LTG 7704571665 TO:3148214162 PAGE:02/0S 1FFX.E108027 - Fixture Fittings Page 1 of 1 IFFX.F108027 Fixture Fittings Pag Bottom Notice of Disclaimer Fixture Fittings Guide Information COOPER LIGHTING, DIV OF COOPER INDUSTRIES INC US 19 S 601 S BROAD ST PO BOX 586 ELLAVILLE, GA 31806 USA E108027 Page Ton Notice of Disclaimer This page and all contents are Copyright 2000 by Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under Ws Follow Up Service. Only those products bearing the UL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. .../showpage.html?name=IFFX.E108027&ccnshorttit1c —Fixture+Fittings&objid=1074097481/04/04/2000 Received: 4/13/00 9:24AM; 7704571665 -> CASCO CORP; Page 3 APR-13 00 10:21 FROM:ADDISON PARRISH LTG 7704571665 TO:3148214162 PAGE:03/08 QQVX.E77616 - Manufactured Wiring Systems Page 1 of 1 QQVX.E77616 Manufactured Wiring Systems Page Bottom Notice of Disclaimer Manufactured Wiring Systems Guide Information COOPER LIGHTING, DIV OF COOPER INDUSTRIES INC US 19 S 601 S BROAD ST PO BOX 586 ELLAVILLE, GA 31806 USA E77616 Adapters, Cable adapters, Cable sets, Converter boxes, Converter modules, Drop cables, Duplex receptacle boxes, Feeder adapters, Power drop modules, . Snap -in cable combinations, Snap -in drop cables, Snap -in selector modules, Snap -in switch modules, Splitters, Splitter cables, Switch adapters, Switch blockors, Switch drop modules, Tee taps. Page Tops Notice of Disclaimer This page and all contents are Copyright ® 2000 by Underwriters Laboratories Inc.® The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow -Up Service. Only those products bearing the IJL Mark should be considered to be Listed and covered under UL's Follow -Up Service. Always look for the Mark on the product. .../showpage.html7name=QQVX.E77616&ccnshorttitle=Manufactured+Wiring+Systems&objiO4/ 13 /2000 vP❑\E\TS U IL^' LiJ W S eL W I..L LL LJ -J Q U W W 1_ B 0q wgdi r 0 ta ea BY. 3W.W fT u nrAt NII .. J7 1 1 1 1 >..N14Z°4 4-r q !Vita maim 0Z0 3 rQISI 7iy<O ppNI`1. OJrI- _.pJ 1: WW pWJJpgq1- F� 0 u a 0 es c A CZ W a_ LJ W W L 4 Waqa biT Nb i l > NNN FSA SYSTEM NNN ibdVX9 II.A4 7 e 1=k qgi CABLE ADAPTER 23 v< V / W GQ U u>n»> .-NNN>>Nfm l N N N CC h— nJ LL 'SPLITTERS CARRY ALL CIRCUITS' w 0_ A V / W J W 1J>. <o1.a♦ N NNN♦ > NNN Received: 4/13/00 9:24AM; 7704571665 APR-13 00 10:22 FROM:ADDISON PARRISH LTG 7704571665 -> CASCO CORP; Page 4 TO:3148214162 PAGE:04'08 FSA Female SO Cord Adapter System for HID Lighting The FSA System is the ultimate for HID Installation. This gives total flexibility and versatility. Fixtures can be removed without disrupting power downhrfe. Cleaning and repairing, or replacing fixtures is accomplished easily and quickly. Feeder Mepwr FA) Cable Se1(C1 ills - woo 8 TeaTeprfn Cobb 6a1(C1 Ten Tap (r1l 11110171 'moots 110 Car Meow ws Cable Gel (Ct1 Too Tea 071 law Panda AO Cad ieaale SO CM Adaptor(F$N ��/ e. /Wpur(FOA) scald k e.aQOeRded on fixtures and MWS system apptcaeons. Received: 4/13/00 9:24AM; 7704571665 -> CASCO CORP; Page 5 APR-13 00 10:22 FROM:ADDISON PARRISH LTG 7704571665 TO:3142214162 PAGE:05/0B Modular Wiring H.I. D, Fixtures It's about time MWS is Contractor Friendly . . 3: t 1 You'll install three H.I.D. fixtures with MWS In the time it takes to hardwire one fixture. MWS saves for You MWS ,Received: 4/13/00 9:24AM; 7704571665 APR-13 00 10:22 FROM:ADDISON PARRISH LTG 7704571665 -> CASCO CORP; Page 6 TO:3148214162 PAGE:06/08 8111 of Material ppyy �ore tb61. 1r1'conduit dedon 10 4" awes 10 4" J corer 20 1I2' conduN connectors 7 112" conduit melon 4801 30 eWNrre ke nuts Conduit cusps am hansom 1e e It's about time...Total Time Investment A point of difference In productivity` profitability The biggest cost in conventional wiring of H.I.D. fixtures is time -on-the-job labor oast. That's true regardless of labor cost per hour—$12 to $60, It can make or break any job, large or small. Labor time Is a cost burden that's rough In a competitive marketplace. It can crimp profitability. It's sound common sense that profit- ability per job will increase as the labor cost per job is cut. Time Is money...MWS Is 300% faster MWS from Metalux works for the con- tractor and apeoifier. It will cut labor cost per job. Each H.I.D. fadure can be installed with MWS in one-third the time it takes with conventional wiring. -Without exception. MWS is a concept brought into reality to benefit you and your business. MWS employe engineered, pre -wired modular components. Quality com- ponents that work together. With precise results. MWS is a *lend indeed...a contributor to bottom -line business performance. H.I.D. HARDWIRING Step t • Stub up • Set junction boxes • Cut conduit • Sat fixture mounting boxes Stop 2 • Pull wire • Cut and strip conductors Step 3 • Hang fbcture • Connect wires to fixture with wire nuts 20' 20' Mounting Height u� e a Ybut $ 1.e2 per 101 . 7• 6 7.80 ao .34 .45 .06 ,06 . 60 .e0 Idle Cost YstaUt coot per Ostuso a) 3.40 4.00 3.15 2180 1.50 too 4.0o •177 11145 NOTE: Support conduit and fixture per N.E.G. ,Received: 4/13/00 9:25AM; 7704571665 APR-13 00 10:22 FROM:ADDISON PARRISH LTG 7704571665 -> CASCO CORP; Page 7 TO:3148214162 PAGE:07/08 Contractor friendly becomes a reality MWS from Metalux is different. For that reason, a contractor should ask: "What's in it for me?" The answer: Greater profit opportunity per jobl The contractor crew is on and off the job -site faster with MWS. Fewer components. Less work Fewer decisions. Less confusion. Fewer tasks. Less effort. It is a matter of time. And, that's just,the beginning. You have time for more jobs. More profit opportunities. You can take on jobs you once had to forget for lack of time. Added benefits, too. Estimating is easier, faster, more accurate. You can depend on it. Base for true profitability Total installed cost is the "real world" way to approach profit opportunity in wiring for lighting fixtures. With MWS...more is less to produce greater results. For H.I.D. lighting, you'll install three fixtures with MWS, In the same time it takes to hardwire a single fxture. Nick pigs hart shows you how MWS Y� Saves Labor 3: t H.I.D. WITH MWS Step 1 • Stub up • Install junction boxes • Install fixture mounting bracket Step 2 ■ Pull wire ■ Connect to FA Stop 3 • �fixtures a factory installed) • Rcable • Plug cable into TSA 20' 20' Mounting Height 8111 of Maturlal qnr Pert c..I+ Unit Pric . 3 'FA700 $ 7.06 2 'C111 16.15 0 'C121 21.05 • •rSA1w 11.06 Ami.w ,....«�.,wrrm UNN 1bNhOM MsiPW cou$ pudisi . (5) $ 14.10 30.30 131.70