R2004-077 05-24-04 RESOLUTION NO. R2004-77
A RESOLUTION OF THE CITY COUNCIL OF THE CITY OF PEARLAND,
TEXAS, AWARDING A BID FOR CONSTRUCTION OF PARKING
IMPROVEMENTS AT THE PEARLAND SERVICE CENTER.
BE IT RESOLVED BY THE CITY COUNCIL OF THE CITY OF PEARLAND, TEXAS:
Section 1. That the City opened bids for construction of parking improvements at
the Pearland Service Center, and such bids have been reviewed and tabulated.
Section 2. That the City Council hereby awards the bid to Crosstex Construction,
in the amount of $78,551.00.
Section 3. The City Manager or his designee is hereby authorized to execute a
contract for construction of parking improvements at the Pearland Service Center.
PASSED, APPROVED and ADOPTED this the 24th day of May ,
A.D., 2004.
ATTEST:
APPROVED AS TO FORM:
DARRIN M. COKER
CITY ATTORNEY
TOM REID
MAYOR
0
Auociatest Inc.
06May, 2004 e � '�.
- Mr. Jerry Burns 7
NAY 2nn
City of Pearland Cstjy of �r
3501 East Orange Street_ Se�l�e"
Pearland,TX 77581 ' 9?ter,
RE; Contractor Selection Recommendation
Pearland Service Center.Improvements(COP No.:2004-050);
•
Dear Mr:. Burns; .
After reviewing the three (3) bid submittals for the referenced project,JKC:recommends:
that the City consider extending a contract:to Crostex Construction, Inc:for the bid
amount of.$63,855.00. ; . .
Crostex was the low bidder on this project, and:has an acceptable work history as
described by references provided by Crostex. :JKC does not have direct experience
. .,with this firm, but our research of recent and current Crostex clients leads us to believe •
they have the means and experience to provide these_improvements in a timely and cost
effective manner.:
Please do not hesitate to call me:at(281) 332-1120.if you have any questions, comments
'or.concerns.' _
Sincerely,
JKC•&Associates, Inc
Jason.Christian, Pl.
•
c: File 03 0704
•
2820 FM 517 E•Dickinson,TX 77539 phone:(281)309-9100•FAX: (281)309-9300 -
Associates,:Inc.
06 May, 2004
Mr. Jerry Burns
City of Pearland R E`C �. .
3501 East Orange Street ,
Pearland, TX 77581 NAY 0.
7 2004
City of' ar1
RE: Potential Change Order: to Complete Paving Project ` Service C and
Pearland Service Center Improvements (COP No.2004-050) enter
Dear Mr:Burns;.
We have revised the drawing to show the pavement that the City has already placed and
- the revised extent of work for the Contractor to place as part of his base bid. After
making this adjustment, there will be an additional 668''SY of 6"pavement to complete
the entire proposed parking area.
If you choose to have Crostex complete the entire project, it will increase the contract
amount by$14,696 (668 SY * $22/SY) for total contract amount of$78,551.
Please do not hesitate to call me at(281).309-9100 if you have any questions, comments
or concerns. •
Sincerely, -, .
JKC.&:Associates,-Inc.
Jason Christian, P.E.
c:.. File 03-0704
2820 FM 517 E•Dickinson,TX 77539•phone`.(281)309-9100•FAX:(281'):309-9300
r
I PROP FENCE GRATE INLET I pw ' I
12"PINEI [(By OTHERS) 18"(N)40.41 I
EP 43.85 18"(S)41.44to
I
❑ ❑ ❑ oa aary ti 18"(W)40.45 I 4
�95 ,5e ,OPEP 43.75 ,! ay• a','1 1` 0 0
�. .} 4. any a'h �eP _ ti
12"PINE i7:1P 43.70 62.0' 18"STM a Y-* , s,
WOOD ,"
Q I 1 STORY MEiALl1C BLDGON fl GRATE INLET
�P I N rib BLKS = TOP 43.15 I e`
o g GRATE w/ 0 18"(E)40.65 co ®-k.
N I o NO VISIBLE �5 _, EB I
Et:I o 11 171.00 p LEADS --�� = ti > I ° --i
a 1 24111,1
�I�o 62.0' t ah^ 2
�P III 1. I ,.� b r ro0 ,p
�;r CONC STEPS y. I -
tr
P.
\°� a�611 aye V a��+ I mil` PROP FENCE ye` ON SLAB ay� t.
PA ry� aa?
Z �" o o I (BY OTHERS) I EP 43.10 GRATE INLET
11 I to :� I ea ¢o (6)C/O I (6)PVC PIPES R2' 6 TOP 43.39 (ADJUST TO 43.00)
11 9.00 O O II ❑• ° • • • • • •I • • • • • • • --it‘ - '1' 18'(N)40.67 1
�`' 133.7' hob REMOVE 374 SF-.. k N.
23t„8.o z I U W ° EXISTING CONC PAD I f _J\ 11 TTT 4�
U a I i 00-H ,TP 4,.15� F see 6`1.41
'� I I 2 *OP 6"
IA In W - II II 8 CONC PVMTQ 18"5'
`L n , � CD I 1 W M
t . w a 1• a�6 w I -co. .' 180.....
1 16 60-
* p a�a�i hry„ c- M 1 STORY METALLIC fO I 5 , 2. GRATE INLE
a' n 4' :.�1 $..: F-18 0. ,. i 1.o,C� TOP 44.19
of �zw \ I ')v I v a z 18"(S)40.5•
w)p a �� Z REMOVE AC & U i a7
P 43.50m �' o.0 v GRATE INLET 4P 67 SF CONC PAD C \ $ t2 .'aPROP SWING GATE
a q�w I o_ iiti,
' 133.7' e?' I ■ , tS & FENCE (BY OTHE
a I- I � _,.6' SIDEWALK 6.._SIDEWA� y� 61
h ( p a W- s. LOADING "- E ." V _ 18.00 _
I / �' 4' 1" '••a.'�"sxs,-'e4+`--"^sc . =-'o"cED E ELEV'=`4370--- Py`-
a'S' • a'S6 I ZONE I.,' a a° INLET 02
* t ry-'es + '. GRATE=43.24 o
a�ry�y a I c $9 a� Li
WI i a' 1 FL(127=40.00,..!f �j m
INLET 01 ��®�
PROP 6'
GRATE=43.25 1 - _ c�)1 24.00 CONC PVMT
'43.75 FL(12")=40.30 A
_ _ _ Ct. R SWALE _ f1 L yti4rEL::‘„,..4%.
.
�- REMOVE 4,543 SF 0.25X. Q. 1- FL 42.19 WATER ME
EP 44.00 EXISTING CONCRETE EP 44.OQ PROP 6" PROP 45 LF - EP 43.50 '�-
a. R2'(TYP) I CONC PVMT 12" STORM 0 0.25%
<TE INLET 1 6.25 I I / 5
' 42.62 E 40.67 �I a 3.01 . I -106,00 r �°
(W)40.72 n 2 °tab` 5.251� 24.00 �6.2° I 18.00 % II' w v ti
-�,-.� . mat. IAA .F 1 m 9.00- a - �� r�' ti� "�
a�� - Da G.,_. _ y _._ - 43.S 4 .63 I _�- __LV,®, =e'i d9 T` _- �... a ? .n \ Z
y •
� --�-- 1 r< ELEV = 3. 5 oI�,.c ..::.sru-_CO --'TT o ' =4.. �+'v-' a b s ��
I �o.5/8 -I EP43.75 S 89'S8'00" W 22 09'EP 00 I i � y3. a�69( F
24"STM �I 43,4 24" �_ -,
S II.' SS ` Q 55 24"STM • tE'�5 S
s _ _ s S
,� - CONCRETE---- L:% �� � - -2�M - -
aa"\ atiA v� o HEADWALL --- Imp- a3 s -R Fir Boa po° V e
-G* G - C C •. �� ,•�,. �.. , e G G C rS�.C7 C�G 9, G
a MATCH PVMT ELEV. ASPHALT 6"SAN (APPROXIMATE o "-GRATE INLET
A as a eAb PROP 56 LF GRATE INLET a° No LOCATION UNDER ti o h TOP 42.26
12" STORM 0 0.25% 45.00 TOP 42.81 )` S 89•8'OO' W 229.15' P. STORM SEWER) .,10' rn 18"(N)39.76
90 a 24"(E)40.18 24"((E W)39.52
t? as ,1• OR4NGE STREET 24"(W)40.23 PROP 72 SY 2' oti P.O.B. 6 12'(N)39.85 (PRC
2' IP SR GAS LINE + . y 12"(N)40.18 (PROPa a?° ASPHALT DRIVEWAY D`' *aye ASPHALT +ah�
"(PER BLOCK MAP) (60 P.O.W.) 4a 81 a
w w w w - w w w- w
S / s_w____�-89 N 00'02'00" W71
R
7/1/rill' it!, iG LE LT